Description
A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 1000 V. Operated with wide control voltage range 20-60 V, DC- Part Number
- AF95-30-11-72
- UNSPSC
- 39121529
- ETIM
- Group Code : EG000017
- Group Description : Low-voltage Industrial Components
- Class Description : Power contactor, AC switching
- Class Code : EC000066
- Version : 7
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Dimensions
- Product Net Width
- 102 mm
- Product Net Depth / Length
- 123.5 mm
- Product Net Height
- 148 mm
- Product Net Weight
- 1.9 kg
Technical
- Number of Main Contacts NO
- 3
- Number of Main Contacts NC
- 0
- Number of Auxiliary Contacts NO
- 1
- Number of Auxiliary Contacts NC
- 1
- Rated Operational Voltage
- Main Circuit 1000 V
- Conventional Free-air Thermal Current (Ith)
- acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 145 A
- Rated Operational Current AC-1 (Ie)
- (690 V) 40 °C 145 A(690 V) 55 °C 135 A(690 V) 70 °C 115 A
- Rated Operational Current AC-3 (Ie)
- (415 V) 55 °C 96 A(440 V) 55 °C 93 A(500 V) 55 °C 80 A(690 V) 55 °C 65 A(1000 V) 55 °C 30 A(380 / 400 V) 55 °C 96 A(220 / 230 / 240 V) 55 °C 96
- Rated Operational Power AC-3 (Pe)
- (415 V) 55 kW(440 V) 55 kW(500 V) 55 kW(690 V) 55 kW(1000 V) 40 kW(380 / 400 V) 45 kW(220 / 230 / 240 V) 25 kW
- Rated Breaking Capacity AC-3
- 8 x Ie AC-3
- Rated Making Capacity AC-3
- 10 x Ie AC-3
- Short-Circuit Protective Devices
- gG Type Fuses 160 A
- Maximum Breaking Capacity
- cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A
- Maximum Electrical Switching Frequency
- (AC-1) 300 cycles per hour(AC-2 / AC-4) 150 cycles per hour(AC-3) 300 cycles per hour
- Rated Operational Current DC-1 (Ie)
- (110 V) 2 Poles in Series, 40 °C 145 A(220 V) 3 Poles in Series, 40 °C 145 A
- Rated Operational Current DC-3 (Ie)
- (110 V) 2 Poles in Series, 40 °C 145 A(220 V) 3 Poles in Series, 40 °C 145 A
- Rated Operational Current DC-5 (Ie)
- (110 V) 2 Poles in Series, 40 °C 145 A(220 V) 3 Poles in Series, 40 °C 145 A
- Rated Insulation Voltage (Ui)
- acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 Vacc. to UL/CSA 600 V
- Rated Impulse Withstand Voltage (Uimp)
- Main Circuit 8 kV
- Mechanical Durability
- 10 million
- Maximum Mechanical Switching Frequency
- 300 cycles per hour
- Coil Operating Limits
- (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
- Rated Control Circuit Voltage (Uc)
- DC Operation 20 ... 60 V
- Coil Consumption
- Holding at Max. Rated Control Circuit Voltage 50 Hz 7 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 7 V·AHolding at Max. Rated Control Circuit Voltage DC 2 WPull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 350 V·APull-in at Max. Rated Control Circuit Voltage DC 400 W
- Operate Time
- Between Coil De-energization and NC Contact Closing 60 ... 130 msBetween Coil De-energization and NO Contact Opening 55 ... 125 msBetween Coil Energization and NC Contact Opening 27 ... 77 msBetween Coil Energization and NO Contact Closing 30 ... 80 ms
- Connecting Capacity Main Circuit
- Bar 30 mm²Flexible with Cable End 2 x 6 ... 35 mm²Rigid 2 x 6 ... 65 mm²
- Connecting Capacity Auxiliary Circuit
- Flexible with Ferrule 2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²Flexible 2x0.75 ... 2.5 mm²Solid 2 x 1 ... 4 mm²Stranded 2 x 1 .... 4 mm²
- Degree of Protection
- acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
- Connecting Terminals (delivered in open position) Main Poles
- M8 hexagon socket screw with single connector
- Terminal Type
- Cable Clamp
Classifications
- Object Classification Code
- Q
- ETIM 4
- EC000066 - Magnet contactor, AC-switching
- ETIM 5
- EC000066 - Magnet contactor, AC-switching
- EClass
- V11.0 : 27371003
- IDEA Granular Category Code (IGCC)
- 4763 >> Power contactor, DC switching
Environmental
- Ambient Air Temperature
- Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °CClose to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °CClose to Contactor for Storage -60 ... +80 °C
- Maximum Operating Altitude Permissible
- Without Derating 3000 m
- Resistance to Shock acc. to IEC 60068-2-27
- Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: A 20 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: A 20 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: B1 15 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C1 20 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C2 20 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B1 5 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B2 15 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C1 20 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C2 20 g
- RoHS Status
- Following EU Directive 2011/65/EU
Technical UL/CSA
- Maximum Operating Voltage UL/CSA
- Main Circuit 600 V
- General Use Rating UL/CSA
- (600 V AC) 125 A
- Horsepower Rating UL/CSA
- (200 V AC) Three Phase 30 hp(208 V AC) Three Phase 30 hp(220 ... 240 V AC) Three Phase 30 hp(440 ... 480 V AC) Three Phase 60 hp(550 ... 600 V AC) Three Phase 75 hp
Ordering
- Minimum Order Quantity
- 1 piece
- Customs Tariff Number
- 85364900
- Replacement Product ID (NEW)
- 1SBL407001R1111
Other Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther