ABB
AX09-30-10-84
1 / 1
Description
AX09...AX25 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.- Part Number
- AX09-30-10-84
- UNSPSC
- 39121529
- ETIM
- Group Code : EG000017
- Group Description : Low-voltage Industrial Components
- Class Description : Power contactor, AC switching
- Class Code : EC000066
- Version : 7
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Dimensions
- Product Net Width
- 44 mm
- Product Net Depth / Length
- 74 mm
- Product Net Height
- 74 mm
- Product Net Weight
- 0.326 kg
Technical
- Number of Main Contacts NO
- 3
- Number of Main Contacts NC
- 0
- Number of Auxiliary Contacts NO
- 1
- Number of Auxiliary Contacts NC
- 0
- Rated Operational Voltage
- Auxiliary Circuit 690 VMain Circuit 690 V
- Rated Frequency (f)
- Auxiliary Circuit 50 / 60 HzMain Circuit 50 / 60 Hz
- Conventional Free-air Thermal Current (Ith)
- acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 24 Aacc. to IEC 60947-5-1, Θ = 40 °C 16 A
- Rated Operational Current AC-1 (Ie)
- (220 / 240 V) 55 °C 22 A(690 V) 40 °C 22 A(690 V) 70 °C 18 A
- Rated Operational Current AC-3 (Ie)
- (415 V) 55 °C 9 A(440 V) 55 °C 9 A(500 V) 55 °C 9 A(690 V) 55 °C 7 A(380 / 400 V) 55 °C 9 A(220 / 230 / 240 V) 55 °C 9 A
- Rated Operational Power AC-3 (Pe)
- (415 V) 4 kW(440 V) 4 kW(500 V) 5.5 kW(690 V) 5.5 kW(380 / 400 V) 4 kW(220 / 230 / 240 V) 2.2 kW
- Rated Operational Current AC-15 (Ie)
- (500 V) NC 2(500 V) 2 A(690 V) 2 A(24 / 127 V) 6 A(220 / 240 V) 4 A(380 / 400 V) 3 A(400 / 440 V) 2 A
- Rated Short-time Withstand Current Low Voltage (Icw)
- at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 100 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 26 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 50 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 250 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 60 Afor 0.1 s 140 Afor 1 s 100 A
- Maximum Breaking Capacity
- cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
- Maximum Electrical Switching Frequency
- (AC-1) 600 cycles per hour(AC-15) 1200 cycles per hour(AC-3) 1200 cycles per hour(DC-13) 900 cycles per hour
- Rated Operational Current DC-13 (Ie)
- (24 V) 6 A / 144 W(110 V) 1.1 A / 121 W(125 V) 1.1 A / 138 W(220 V) 0.55 A / 121 W(250 V) 0.55 A / 138 W(400 V) 2.8 A / 134 W(500 V) 2 A / 144 W
- Rated Insulation Voltage (Ui)
- acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
- Rated Impulse Withstand Voltage (Uimp)
- Auxiliary Circuit 6 kV
- Maximum Mechanical Switching Frequency
- 3600 cycles per hour
- Rated Control Circuit Voltage (Uc)
- 50 Hz 110 V60 Hz 110 ... 120 V
- Operate Time
- Between Coil De-energization and NC Contact Closing 9 ... 16 msBetween Coil De-energization and NO Contact Opening 4 ... 11 msBetween Coil Energization and NC Contact Opening 7 ... 21 msBetween Coil Energization and NO Contact Closing 10 ... 26 ms
- Degree of Protection
- acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20IP20
- Terminal Type
- Screw Terminals
Classifications
- Object Classification Code
- Q
- EClass
- V11.0 : 27371003
- IDEA Granular Category Code (IGCC)
- 4755 >> Contactors
- E-Number (Finland)
- 3707306
Environmental
- Ambient Air Temperature
- Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °CClose to Contactor without Thermal O/L Relay -40 ... 70 °CClose to Contactor for Storage -60 ... +80 °CNear Contactor for Operation in Free Air -40 ... 70 °C
- Climatic Withstand
- acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
- Maximum Operating Altitude Permissible
- Without Derating 3000 m
- RoHS Status
- Following EU Directive 2002/95/EC August 18, 2005 and amendment
Technical UL/CSA
- General Use Rating UL/CSA
- (600 V AC) 21 A
- Horsepower Rating UL/CSA
- (120 V AC) Single Phase 1/2 hp(200 ... 208 V AC) Three Phase 2 hp(220 ... 240 V AC) Three Phase 2 hp(240 V AC) Single Phase 1.5 hp(440 ... 480 V AC) Three Phase 5 hp(550 ... 600 V AC) Three Phase 7.5 hp
- Tightening Torque UL/CSA
- Auxiliary Circuit 9 in·lbControl Circuit 9 in·lbMain Circuit 9 in·lb
Ordering
- Minimum Order Quantity
- 1 piece
- Customs Tariff Number
- 85364900
Other Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther