1 / 9
thumbnail
thumbnail
thumbnail
thumbnail
thumbnail
thumbnail
thumbnail
thumbnail
thumbnail

Descripción

Activo maduro
PowerPacT B-Frame brings thermal-mechanical circuit protection in a compact size and offers a wide range of accessories, auxiliaries, and connection options. This PowerPacT B-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600Y/347VAC. All PowerPacT B-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT B-Frame circuit breakers come in 1 to 4-pole unit mount construction and in 1 to 3-pole I-Line construction. This circuit breaker's unit mount construction features traditional back pan mounting with screws or integrated DIN rail mounting for installation flexibility. This unit features EverLink lugs, a patented design to reduce loosening of cables over time, on both termination ends. This PowerPacT B, 90A, 3 pole, circuit breaker has a breaking capacity of 14kA at 600Y/347VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT B circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
Country of Origin
MX
Part Number
BDL36090
Tariff Code
8536200020
EAN
39121601
UNSPSC
39121601
  • Consigue plazos de pago de hasta 90 días de 500+ proveedores.
  • Descuentos de reventa de hasta el 40%!
Registrate
Enviar solicitud de precio
1
Formas de pago:
Solicite un presupuesto y le enviaremos información sobre disponibilidad y precio.

Specifications

Product Or Component Type
circuit breaker
Product Name
PowerPact B
Range
PowerPact
Device Application
distribution
Device Short Name
BD 090

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1610005EN
Sustainable Offer Status
Green Premium product
Pvc Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile
N/A
Eu Rohs Directive
Compliant with Exemptions
Halogen Content Performance
Halogen free product

Environment

Ik Degree Of Protection
IK07 IEC 62262
Ambient Air Temperature For Operation
-25-70 °C
Standards
NEMA AB1 || CSA C22.2 No 5 || EN/IEC 60947-2 || NMX J-266 || GB 14048.2 || EN/IEC 60947-5-1 || UL 489
Product Certifications
UL || IEC || CCC || EAC || CSA || NOM
Ip Degree Of Protection
front cover IP40 IEC 60529
Pollution Degree
3 IEC 60947-1
Ambient Air Temperature For Storage
-50-85 °C
Quality Labels
CE
Operating Altitude
< 6561.68 ft (2000 m) without derating || 5000 m with derating

Complementary

Mounting Mode
clip-on 35 x 15 mm symmetrical DIN rail) || by screws plate)
Network Frequency
50/60 Hz
[Ics] Rated Service Breaking Capacity
25 kA 220...240 V AC 50/60 Hz IEC 60947-2 || 14 kA 500...525 V AC 50/60 Hz IEC 60947-2 || 18 kA 380...415 V AC 50/60 Hz IEC 60947-2 || 18 kA 440 V AC 50/60 Hz IEC 60947-2
Trip Unit Technology
thermal-magnetic
Height
137 mm
Connection Pitch
27 mm
[Ue] Rated Operational Voltage
525 V AC 50/60 Hz UL 489
Tightening Torque
5-5 N.m 2.5-16 mm² (AWG 14...AWG 4) || 9-9 N.m 25-95 mm² (AWG 3...AWG 3/0)
Breaking Capacity Code
D
9 Mm Pitches
9
Local Signalling
presence of auxiliary contacts flag green)
Number Of Slots
1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in) || 1 alarm switch SD plug-in)
Electrical Connection
Everlink lug, line || Everlink lug, load
Net Weight
1.074 kg
[Uimp] Rated Impulse Withstand Voltage
8 kV IEC 60947-2
Control Type
toggle
Circuit Breaker Application
HACR rated
Wire Stripping Length
20 mm
Line Rated Current
90-90 A
Utilisation Category
category A
Continuous Current Rating
80 %
Breaking Capacity
25 kA 208Y/120 V AC 50/60 Hz UL 489 || 25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480/277 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz UL 489 || 14 kA 600Y/347 V AC 50/60 Hz UL 489 || 10 kA 250 V DC UL 489
[Ui] Rated Insulation Voltage
800 V IEC 60947-2
Mechanical Durability
20000 cycles IEC 947-1 Annex K ed 5.2
Suitability For Isolation
yes IEC 60947-2
Electrical Durability
10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
Poles Description
3P
Quantity Per Set
set of 1
Awg Gauge
AWG 6...AWG 2/0 fine stranded aluminium/copper || AWG 14...AWG 3/0 rigid or stranded aluminium/copper
Color
Gray RAL 7016)
Width
81 mm
Depth
80 mm

Documentos

Data Sheet

Descargar