Contactor, high power, TeSys Giga, standard version, 3 pole/NO, AC-3 <=440V 500A, 48-130VAC/DC coil
LC1G500EHEN
  • Consigue plazos de pago de hasta 90 días de 500+ proveedores.
  • Descuentos de reventa de hasta el 40%!
Registrate
Enviar solicitud de precio
1
Formas de pago:
Un total de 11 Parts In-Stock de 17 Distributors

Additional Information

Part Number
LC1G500EHEN
UNSPSC
39121529
Tariff Code
8536490065

Complementary

Product Certifications
CB Scheme || CCC || cULus || EAC || CE || UKCA || EU-RO-MR by DNV-GL
Height
225 mm
Power Dissipation Per Pole
40 W AC-1 - Ith 700 A || 20 W AC-3 - Ith 500 A
Average Impedance
0.00008 Ohm
Auxiliary Contact Composition
1 NO + 1 NC
Connection Pitch
45 mm
[Ith] Conventional Free Air Thermal Current
700 A (at 40 °C)
Standards
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || JIS C8201-5-1
Mounting Support
plate
Hold-In Power Consumption In W
7.8-7.8 W
Rated Breaking Capacity
4600 A at 440 V
Irms Rated Making Capacity
5090 A at 440 V
Associated Fuse Rating
500 A aM at <= 440 V for motor || 400 A aM at <= 690 V for motor || 800 A gG at <= 690 V
Net Weight
7.5 kg
[Uimp] Rated Impulse Withstand Voltage
8 kV
Inrush Power In Va
965-965 VA
Pole Contact Composition
3 NO
Connections - Terminals
power circuit: bar 2 - busbar cross section: 32 x 10 mm || power circuit: lugs-ring terminals 1 185-185 mm² || power circuit: bolted connection || control circuit: push-in 1 0.2-2.5 mm² - cable stiffness: solid stranded without cable end || control circuit: push-in 1 0.25-2.5 mm² - cable stiffness: flexible with cable end || control circuit: push-in 2 0.5-1.0 mm² with cable end || control circuit: push-in 0.75-2.5 mm² - cable stiffness: solid stranded without cable end || control circuit: push-in 0.75-2.5 mm² - cable stiffness: flexible with cable end
Coil Technology
built-in bidirectional peak limiting
Operating Time
40...70 ms closing || 15...50 ms opening
Maximum Operating Rate
600 cyc/h AC-3 || 600 cyc/h AC-3e || 300 cyc/h AC-1 || 150 cyc/h AC-4
Mechanical Durability
8 Mcycles
Tightening Torque
35 N.m
Compatibility Code
LC1G
Hold-In Power Consumption In Va
17.6-17.6 VA
Width
140 mm
Overvoltage Category
III
Depth
226 mm
Maximum Horse Power Rating
150 hp at 200/208 V 60 Hz || 200 hp at 230/240 V 60 Hz || 400 hp at 460/480 V 60 Hz || 450 hp at 575/600 V 60 Hz
Motor Power Kw
147 kW at 230 V AC 50/60 Hz (AC-3e) || 250 kW at 400 V AC 50/60 Hz (AC-3e) || 250 kW at 415 V AC 50/60 Hz (AC-3e) || 280 kW at 440 V AC 50/60 Hz (AC-3e) || 315 kW at 500 V AC 50/60 Hz (AC-3e) || 355 kW at 690 V AC 50/60 Hz (AC-3e) || 335 kW at 1000 V AC 50/60 Hz (AC-3e) || 160 kW at 230 V AC 50/60 Hz (AC-3) || 250 kW at 400 V AC 50/60 Hz (AC-3) || 250 kW at 415 V AC 50/60 Hz (AC-3) || 315 kW at 440 V AC 50/60 Hz (AC-3) || 355 kW at 500 V AC 50/60 Hz (AC-3) || 355 kW at 690 V AC 50/60 Hz (AC-3) || 335 kW at 1000 V AC 50/60 Hz (AC-3) || 150 kW at 230 V AC 50/60 Hz (AC-4) || 250 kW at 400 V AC 50/60 Hz (AC-4) || 250 kW at 415 V AC 50/60 Hz (AC-4) || 295 kW at 440 V AC 50/60 Hz (AC-4) || 295 kW at 500 V AC 50/60 Hz (AC-4) || 355 kW at 690 V AC 50/60 Hz (AC-4) || 280 kW at 1000 V AC 50/60 Hz (AC-4)
[Ui] Rated Insulation Voltage
1000 V
Inrush Power In W
760 W
[Icw] Rated Short-Time Withstand Current
4.0 kA - 10 s || 2.8 kA - 30 s || 2.2 kA - 1 min || 1.5 kA - 3 min || 1.2 kA - 10 min

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP2105013
Sustainable Offer Status
Green Premium product
Pvc Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
China Rohs Regulation
X
Circularity Profile
ENVEOLI2105013
Eu Rohs Directive
Compliant with Exemptions
Halogen Content Performance
Halogen free plastic parts product

Specifications

[Uc] Control Circuit Voltage
48...130 V AC 50/60 Hz || 48...130 V DC
[Ue] Rated Operational Voltage
<= 1000 V AC 50/60 Hz || <= 460 V DC
Range Of Product
TeSys Giga
Control Circuit Voltage Limits
operational: 0.8 Uc Min...1.1 Uc Max (at <60 °C) || drop-out: 0.1 Uc Max...0.45 Uc Min (at <60 °C)
Contactor Application
power switching || motor control
Product Or Component Type
contactor
Range
TeSys
Utilisation Category
AC-1 || AC-3 || AC-3e || AC-4 || AC-5a || AC-5b || AC-6a || AC-6b || AC-8b || AC-8a || DC-1 || DC-3 || DC-5
[Ie] Rated Operational Current
700 A (at <40 °C) at <= 1000 V AC-1 || 500 A (at <60 °C) at <= 440 V AC-3
Poles Description
3P
Device Short Name
LC1G

Environment

Ambient Air Temperature For Operation
-25-60 °C
Ambient Air Temperature For Storage
-60-80 °C
Protective Treatment
TH
Ip Degree Of Protection
IP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106
Mechanical Robustness
vibrations 5-300 Hz 2 gn contactor open || vibrations 5-300 Hz 4 gn contactor closed || shocks 10 gn 11 ms contactor open || shocks 15 gn 11 ms contactor closed
Color
dark grey
Permissible Ambient Air Temperature Around The Device
-40-70 °C at Uc

Documentos

Data Sheet

Descargar

Modelos CAD

Rastrear piezas
Rastrear piezas
Descargar