1 / 1
thumbnail

Description

Sensor/actuator cable, 3-position, Variable cable type, free cable end, on Socket angled M12, coding: A, cable length: Free input (0.2 ... 40.0 m)
Country of Origin
PL
Part Number
1696714
ETIM
Group Code : EG000026
Group Description : Sensors
Class Description : Sensor-actuator patch cord
Class Code : EC001855
Version : 7
Payment methods:
Best offer from:
USAutoma.Net Supplier
Availability:
1 pc.
In-Stock
Updated at: 11-07-2024
Estimated Delivery:
On Request
Condition:
New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
A total of 200 Parts In-Stock from 5 Distributors
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies

Available Offers (4)

1696714 product image
Phoenix Contact

1696714

Condition:
New Surplus
Available:
66 pcs.
In-Stock
Updated at: 03-11-2024
Offer from:
DETrusted Automa.Net Supplier
Estimated Delivery:
11-13 November to United Kingdom
Warranty:
12 months
1
€10.00
net
Shipping from:
€20.00
1696714 product image
Phoenix Contact

1696714

Condition:
New Surplus
Available:
66 pcs.
In-Stock
Updated at: 05-11-2024
Offer from:
GBTrusted Automa.Net Supplier
Estimated Delivery:
On Request
Warranty:
12 months
1
1696714 product image
Phoenix Contact

1696714

Condition:
New Surplus
Available:
66 pcs.
In-Stock
Updated at: 05-11-2024
Offer from:
FRTrusted Automa.Net Supplier
Estimated Delivery:
On Request
Warranty:
12 months
1
1696714 product image
Phoenix Contact

1696714

Condition:
New Surplus
Available:
1 pc.
In-Stock
Updated at: 21-10-2024
Offer from:
GBTrusted Automa.Net Supplier
Estimated Delivery:
On Request
1

PVC yellow 105 °C [542]

Cable type
PVC yellow 105 °C
Cable type (abbreviation)
542
Conductor cross section
0.34 mm²
AWG signal line
22
Conductor structure signal line
42x 0.10 mm
Core diameter including insulation
1.55 mm ±0.05 mm
Thickness, insulation
≥ 0.38 mm (Core insulation)
Thickness, insulation
≥ 0.76 mm (Outer cable sheath)
Wire colors
brown, blue, black
Overall twist
3 wires, twisted
External sheath, color
yellow
External cable diameter D
5.2 mm ±0.2 mm
Cable weight
38 kg/km
Outer sheath, material
PVC
Material conductor insulation
PVC
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 100 MΩ*km (at 20 °C)
Conductor resistance
max. 58 Ω/km (at 20 °C)
Nominal voltage, cable
300 V
Test voltage, cable
4000 V
Flame resistance
according to DIN 50265-2-1

PUR halogen-free gray [280]

Cable type
PUR halogen-free gray
Cable type (abbreviation)
280
Cable abbreviation
Li9Y11Y
UL AWM style
20549
Conductor cross section
0.34 mm²
AWG signal line
22
Conductor structure signal line
42x 0.10 mm
Core diameter including insulation
1.27 mm ±0.02 mm
Thickness, insulation
0.21 mm (Core insulation)
Thickness, insulation
approx. 0.8 mm (Outer cable sheath)
Wire colors
brown, blue, black
Overall twist
3 wires, twisted
External sheath, color
gray RAL 7001
External cable diameter D
4.4 mm ±0.15 mm
Cable weight
26 kg/km
Outer sheath, material
PUR
Material conductor insulation
TPE
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 10 GΩ*km (at 20 °C)
Conductor resistance
max. 58 Ω/km (at 20 °C)
Nominal voltage, cable
≤ 300 V
Test voltage, cable
≥ 3000 V
Halogen-free
in accordance with DIN VDE 0472 part 815
Ambient temperature (operation)
-25 °C - 80 °C (cable, fixed installation)

Gray, highly flexible PUR [800]

Note
Due to the extremely robust outer sheath, this cable should only be stripped in 5 cm increments.
Cable type
Gray, highly flexible PUR
Cable type (abbreviation)
800
Cable abbreviation
LiF9Y11Y
UL AWM style
20549
Conductor cross section
3x 0.34 mm² (Signal line)
AWG signal line
22
Conductor structure signal line
42x 0.10 mm
Core diameter including insulation
1.3 mm ±0.05 mm (Signal line)
Wire colors
brown, blue, black
Overall twist
3 wires, twisted
External sheath, color
gray RAL 7001
External cable diameter D
4.5 mm ±0.2 mm
Minimum bending radius, fixed installation
4 x D
Minimum bending radius, flexible installation
7.5 x D
Number of bending cycles
10000000
Minimum bending radius, drag chain applications
7,5 x D
Traversing path
5 m
Traversing rate
3.3 m/s
Acceleration
5 m/s²
Number of bending cycles
15000000
Bending radius
50 mm
Traversing path
0.9 m
Traversing rate
5 m/s
Acceleration
30 m/s²
Torsion force
± 360 °/m (1 000 000 torsion cycles)
Cable weight
28.3 kg/km
Outer sheath, material
PUR
Material conductor insulation
PP
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 20 MΩ*km
Conductor resistance
approx. 53 Ω/km
Nominal voltage, cable
300 V
Test voltage, cable
2000 V
Special properties
Cable jacket is welding spark-resistant, recyclable, matt, low-adhesion, abrasion-resistant, flame-retardant, and self-extinguishing
Special properties
Free from silicone and cadmium
Special properties
Free of substances which would hinder coating with paint or varnish
Flame resistance
in accordance with UL 758/1581 FT2
Halogen-free
in accordance with DIN VDE 0472 part 815
Resistance to oil
in accordance with DIN EN 60811-2-1
Other resistance
Highly resistant to acids, alkaline solutions and solvents
Other resistance
Silicone-free
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-25 °C - 80 °C (cable, flexible installation)

PVC black [PVC]

Cable type
PVC black
Cable type (abbreviation)
PVC
Cable abbreviation
LiYY
UL AWM style
2464 / 1729 (80°C/300 V)
Conductor cross section
3x 0.34 mm² (Signal line)
AWG signal line
22
Conductor structure signal line
42x 0.10 mm
Core diameter including insulation
1.45 mm ±0.02 mm
Thickness, insulation
≥ 0.23 mm (Core insulation)
Wire colors
brown, blue, black
Overall twist
3 wires, twisted
External sheath, color
black RAL 9005
Outer sheath thickness
≥ 0.76 mm
External cable diameter D
5.2 mm ±0.2 mm
Minimum bending radius, fixed installation
5 x D
Minimum bending radius, flexible installation
10 x D
Cable weight
40 kg/km
Outer sheath, material
PVC
Material conductor insulation
PVC
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 100 MΩ*km (at 20 °C)
Conductor resistance
max. 58 Ω/km (at 20 °C)
Nominal voltage, cable
≤ 300 V
Test voltage, cable
≥ 2500 V
Flame resistance
As per UL-Style 2464
Resistance to oil
According to DIN EN 60811-2-1, 168 h at 90°C
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-25 °C - 80 °C (cable, flexible installation)

PUR/PVC gray [100]

Cable type
PUR/PVC gray
Cable type (abbreviation)
100
Cable abbreviation
LiYY-11Y
Conductor cross section
0.34 mm²
AWG signal line
22
Conductor structure signal line
42x 0.10 mm
Core diameter including insulation
1.5 mm ±0.05 mm
Thickness, insulation
≥ 0.23 mm (Core insulation)
Thickness, insulation
≥ 0.38 mm (Outer cable sheath)
Thickness, insulation
approx. 0.5 mm (Inner sheath)
Wire colors
brown, blue, black
Overall twist
3 wires, twisted
External sheath, color
gray RAL 7001
External cable diameter D
5.2 mm ±0.2 mm
Smallest bending radius, fixed installation
26 mm
Smallest bending radius, movable installation
52 mm
Number of bending cycles
2000000
Bending radius
52 mm
Traversing path
5 m
Traversing rate
3 m/s
Cable weight
37 kg/km
Outer sheath, material
PUR
Material, inner sheath
PVC
Material conductor insulation
PVC
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 100 MΩ*km (at 20 °C)
Conductor resistance
max. 58 Ω/km (at 20 °C)
Nominal voltage, cable
≤ 300 V
Test voltage, cable
≥ 3000 V
Flame resistance
in accordance with DIN UL-Style 20549
Ambient temperature (operation)
-25 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-5 °C - 80 °C (cable, flexible installation)

PUR irradiated halogen-free orange [150]

Cable type
PUR irradiated halogen-free orange
Cable type (abbreviation)
150
Cable abbreviation
D12YSL11X-OB
Conductor cross section
3x 0.34 mm² (Signal line)
AWG signal line
22
Conductor structure signal line
42x 0.10 mm
Core diameter including insulation
1.05 mm ±0.05 mm (Signal line)
Wire colors
brown, blue, black
Overall twist
3 wires, twisted
External sheath, color
orange RAL 2003
External cable diameter D
4.4 mm ±0.2 mm
Smallest bending radius, fixed installation
13.5 mm
Smallest bending radius, movable installation
53 mm
Number of bending cycles
5000000
Bending radius
44 mm
Traversing path
10 m
Traversing rate
3 m/s
Acceleration
10 m/s²
Outer sheath, material
PUR
Material conductor insulation
PE
Conductor material
Bare Cu litz wires
Conductor resistance
max. 57 Ω/km
Nominal voltage, cable
250 V (AC)
Test voltage, cable
2000 V (50 Hz, 5 minutes)
Special properties
Silicone-free
Special properties
Irradiated
Flame resistance
according to DIN VDE 0472 Part 804
Other resistance
UV resistant
Ambient temperature (operation)
-50 °C - 105 °C (cable, fixed installation)
Ambient temperature (operation)
-40 °C - 105 °C (cable, flexible installation)

Dimensions

Length of cable
Free input (0.2 - 40.0 m)
Stripping length of the free conductor end
50 mm

Material

Flammability rating according to UL 94
HB
Contact material
CuSn
Contact surface material
Ni/Au
Contact carrier material
TPU GF
Material of grip body
TPU, hardly inflammable, self-extinguishing
Material, knurls
Zinc die-cast, nickel-plated
Sealing material
NBR

PVC yellow [540]

Cable type
PVC yellow
Cable type (abbreviation)
540
Cable abbreviation
LiYY
Conductor cross section
0.34 mm²
AWG signal line
22
Conductor structure signal line
42x 0.10 mm
Core diameter including insulation
1.45 mm ±0.05 mm
Thickness, insulation
≥ 0.23 mm (Core insulation)
Thickness, insulation
≥ 0.76 mm (Outer cable sheath)
Wire colors
brown, blue, black
Overall twist
3 wires, twisted
External sheath, color
yellow
External cable diameter D
5.2 mm ±0.2 mm
Cable weight
40 kg/km
Outer sheath, material
PVC
Material conductor insulation
PVC
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 1 GΩ*km (at 20 °C)
Conductor resistance
max. 58 Ω/km (at 20 °C)
Nominal voltage, cable
≤ 300 V
Test voltage, cable
≥ 3000 V
Flame resistance
As per UL-Style 2464
Ambient temperature (operation)
-25 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-5 °C - 80 °C (cable, flexible installation)

PUR/PVC yellow [140]

Cable type
PUR/PVC yellow
Cable type (abbreviation)
140
Cable abbreviation
LiYY-11Y
Conductor cross section
0.34 mm²
AWG signal line
22
Conductor structure signal line
42x 0.10 mm
Core diameter including insulation
1.52 mm ±0.02 mm
Thickness, insulation
≥ 0.23 mm (Core insulation)
Thickness, insulation
≥ 0.38 mm (Outer cable sheath)
Thickness, insulation
approx. 0.45 mm (Inner sheath)
Wire colors
brown, blue, black
Overall twist
3 wires, twisted
External sheath, color
yellow
External cable diameter D
5.2 mm ±0.2 mm
Smallest bending radius, fixed installation
52 mm
Smallest bending radius, movable installation
52 mm
Number of bending cycles
2000000
Bending radius
52 mm
Traversing path
5 m
Traversing rate
3 m/s
Cable weight
37 kg/km
Outer sheath, material
PUR
Material, inner sheath
PVC
Material conductor insulation
PVC
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 100 MΩ*km (at 20 °C)
Conductor resistance
max. 57.3 Ω/km (at 20 °C)
Nominal voltage, cable
300 V
Test voltage, cable
2500 V
Ambient temperature (operation)
-25 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-5 °C - 80 °C (cable, flexible installation)

PUR halogen-free black [PUR]

Cable type
PUR halogen-free black
Cable type (abbreviation)
PUR
Cable abbreviation
Li9Y11Y
UL AWM style
20549
Conductor cross section
3x 0.34 mm² (Signal line)
AWG signal line
22
Conductor structure signal line
42x 0.10 mm
Core diameter including insulation
1.27 mm ±0.02 mm (Signal line)
Thickness, insulation
≥ 0.21 mm (Core insulation)
Thickness, insulation
approx. 0.5 mm (Outer cable sheath)
Wire colors
brown, blue, black
Overall twist
3 wires, twisted
External sheath, color
black-gray RAL 7021
External cable diameter D
3.85 mm ±0.15 mm
Smallest bending radius, fixed installation
19 mm
Smallest bending radius, movable installation
38 mm
Number of bending cycles
10000000
Bending radius
44 mm
Traversing path
10 m
Traversing rate
3 m/s
Acceleration
10 m/s²
Cable weight
23 kg/km
Outer sheath, material
PUR
Material conductor insulation
PP
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 100 GΩ*km (at 20 °C)
Conductor resistance
max. 58 Ω/km (at 20 °C)
Nominal voltage, cable
≤ 300 V
Test voltage, cable
≥ 3000 V
Special properties
Flexible cable conduit capable
Special properties
Silicone-free
Special properties
Free of substances which would hinder coating with paint or varnish
Flame resistance
in accordance with UL 758/1581 FT2
Flame resistance
DIN EN 60332-2-2 (20 s)
Halogen-free
in accordance with DIN VDE 0472 part 815
Resistance to oil
in accordance with DIN EN 60811-2-1
Other resistance
Highly resistant to acids, alkaline solutions and solvents
Other resistance
hydrolysis and microbe resistant
Other resistance
partly UV-resistant in accordance with DIN EN ISO 4892-2-A
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-25 °C - 80 °C (cable, flexible installation)

PVC gray [500]

Cable type
PVC gray
Cable type (abbreviation)
500
Cable abbreviation
LiYY
Conductor cross section
0.34 mm²
AWG signal line
22
Conductor structure signal line
42x 0.10 mm
Core diameter including insulation
1.45 mm ±0.02 mm
Thickness, insulation
≥ 0.23 mm (Core insulation)
Thickness, insulation
≥ 0.76 mm (Outer cable sheath)
Wire colors
brown, blue, black
Overall twist
3 wires, twisted
External sheath, color
gray RAL 7001
External cable diameter D
5.2 mm ±0.2 mm
Cable weight
40 kg/km
Outer sheath, material
PVC
Material conductor insulation
PVC
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 1 GΩ*km (at 20 °C)
Conductor resistance
max. 58 Ω/km (at 20 °C)
Nominal voltage, cable
≤ 300 V
Test voltage, cable
≥ 3000 V
Flame resistance
As per UL-Style 2464
Ambient temperature (operation)
-25 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-5 °C - 80 °C (cable, flexible installation)

Ambient conditions

Ambient temperature (operation)
-25 °C - 90 °C (Plug / socket)
Degree of protection
IP65
Degree of protection
IP67
Degree of protection
IP68

Line characteristics

Note
This item is a sensor/actuator cable with a freely selectable cable type. The technical data for all possible cable types is listed in the table below.

Environmental Product Compliance

China RoHS
Environmentally friendly use period: unlimited = EFUP-e
China RoHS
No hazardous substances above threshold values

Standards and Regulations

Standards/specifications
M12 connector IEC 61076-2-101
Flammability rating according to UL 94
HB

PUR/PVC orange [110]

Cable type
PUR/PVC orange
Cable type (abbreviation)
110
Cable abbreviation
LiYY-11Y
Conductor cross section
0.34 mm²
AWG signal line
22
Conductor structure signal line
42x 0.10 mm
Core diameter including insulation
1.52 mm ±0.02 mm
Thickness, insulation
≥ 0.23 mm (Core insulation)
Thickness, insulation
≥ 0.38 mm (Outer cable sheath)
Thickness, insulation
approx. 0.45 mm (Inner sheath)
Wire colors
brown, blue, black
Overall twist
3 wires, twisted
External sheath, color
orange RAL 2003
External cable diameter
5.20 mm
Smallest bending radius, fixed installation
52 mm
Smallest bending radius, movable installation
52 mm
Number of bending cycles
2000000
Bending radius
52 mm
Traversing path
5 m
Traversing rate
3 m/s
Cable weight
37 kg/km
Outer sheath, material
PUR
Material, inner sheath
PVC
Material conductor insulation
PVC
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 100 MΩ*km
Conductor resistance
max. 57.3 Ω/km
Nominal voltage, cable
300 V
Test voltage, cable
2500 V
Ambient temperature (operation)
-25 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-5 °C - 80 °C (cable, flexible installation)

Related products