1 / 1
thumbnail

Description

Sensor/actuator cable, 3-position, Variable cable type, Plug straight M12, coding: A, on Socket angled M8, cable length: Free input (0.2 ... 40.0 m)
Country of Origin
PL
Part Number
1696866
ETIM
Group Code : EG000026
Group Description : Sensors
Class Description : Sensor-actuator patch cord
Class Code : EC001855
Version : 7
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

PUR halogen-free gray [280]

Cable type
PUR halogen-free gray
Cable type (abbreviation)
280
Cable abbreviation
Li9Y11Y-HF
UL AWM style
20549 / 10493 (80°C/300 V)
Conductor cross section
3x 0.25 mm²
AWG signal line
24
Conductor structure signal line
32x 0.10 mm
Core diameter including insulation
1.17 mm ±0.02 mm
Thickness, insulation
≥ 0.21 mm (Core insulation)
Wire colors
brown, blue, black
Overall twist
3 wires, twisted
Length of twist, overall twist
40 mm
External sheath, color
gray RAL 7001
Outer sheath thickness
approx. 0.5 mm
External cable diameter D
3.6 mm ±0.15 mm
Smallest bending radius, fixed installation
18 mm
Smallest bending radius, movable installation
36 mm
Number of bending cycles
10000000
Bending radius
44 mm
Traversing path
10 m
Traversing rate
3 m/s
Acceleration
10 m/s²
Cable weight
18 kg/km
Outer sheath, material
PUR
Material conductor insulation
PP
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 100 GΩ*km (at 20 °C)
Conductor resistance
≤ 78 Ω/km (at 20 °C)
Nominal voltage, cable
≤ 300 V
Test voltage, cable
≥ 3000 V
Special properties
Flexible cable conduit capable
Special properties
Silicone-free
Special properties
Free of substances which would hinder coating with paint or varnish
Flame resistance
in accordance with UL 758/1581 FT2
Flame resistance
DIN EN 60332-2-2 (20 s)
Halogen-free
in accordance with DIN VDE 0472 part 815
Resistance to oil
in accordance with DIN EN 60811-2-1
Other resistance
hydrolysis and microbe resistant
Other resistance
Highly resistant to acids, alkaline solutions and solvents
Other resistance
Resistant to salt water
Other resistance
partly UV-resistant in accordance with DIN EN ISO 4892-2-A
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-25 °C - 80 °C (cable, flexible installation)

Gray, highly flexible PUR [800]

Note
Due to the extremely robust outer sheath, this cable should only be stripped in 5 cm increments.
Cable type
Gray, highly flexible PUR
Cable type (abbreviation)
800
Cable abbreviation
LiF9Y11Y
UL AWM style
20549
Conductor cross section
3x 0.25 mm² (Signal line)
AWG signal line
24
Conductor structure signal line
32x 0.10 mm
Core diameter including insulation
1.2 mm ±0.05 mm (Signal line)
Wire colors
brown, blue, black
Overall twist
3 wires, twisted
External sheath, color
gray RAL 7001
External cable diameter D
4.3 mm ±0.2 mm
Minimum bending radius, fixed installation
4 x D
Minimum bending radius, flexible installation
7.5 x D
Number of bending cycles
10000000
Minimum bending radius, drag chain applications
7,5 x D
Traversing path
5 m
Traversing rate
3.3 m/s
Acceleration
5 m/s²
Number of bending cycles
15000000
Bending radius
50 mm
Traversing path
0.9 m
Traversing rate
5 m/s
Acceleration
30 m/s²
Torsion force
± 360 °/m (1 000 000 torsion cycles)
Cable weight
24 kg/km
Outer sheath, material
PUR
Material conductor insulation
PP
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 20 MΩ*km
Conductor resistance
approx. 76 Ω/km
Nominal voltage, cable
300 V
Test voltage, cable
2000 V
Special properties
Cable jacket is welding spark-resistant, recyclable, matt, low-adhesion, abrasion-resistant, flame-retardant, and self-extinguishing
Special properties
Free from silicone and cadmium
Special properties
Free of substances which would hinder coating with paint or varnish
Flame resistance
in accordance with UL 758/1581 FT2
Halogen-free
in accordance with DIN VDE 0472 part 815
Resistance to oil
in accordance with DIN EN 60811-2-1
Other resistance
Highly resistant to acids, alkaline solutions and solvents
Other resistance
Silicone-free
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-25 °C - 80 °C (cable, flexible installation)

PVC black [PVC]

Cable type
PVC black
Cable type (abbreviation)
PVC
Cable abbreviation
LiYY
Conductor cross section
3x 0.25 mm² (Signal line)
AWG signal line
24
Conductor structure signal line
32x 0.10 mm
Core diameter including insulation
1.25 mm ±0.02 mm
Thickness, insulation
≥ 0.23 mm (Core insulation)
Wire colors
brown, blue, black
Overall twist
3 wires, twisted
External sheath, color
black RAL 9005
Outer sheath thickness
≥ 0.76 mm
External cable diameter D
4.4 mm ±0.15 mm
Cable weight
29 kg/km
Outer sheath, material
PVC
Material conductor insulation
PVC
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 100 MΩ*km (at 20 °C)
Conductor resistance
max. 78 Ω/km (at 20 °C)
Nominal voltage, cable
≥ 300 V
Test voltage, cable
≤ 3000 V
Flame resistance
As per UL-Style 2464
Ambient temperature (operation)
-25 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-5 °C - 80 °C (cable, flexible installation)

PUR/PVC gray [100]

Cable type
PUR/PVC gray
Cable type (abbreviation)
100
Cable abbreviation
LiYY-11Y
Conductor cross section
0.25 mm²
AWG signal line
24
Conductor structure signal line
32x 0.10 mm
Core diameter including insulation
1.32 mm ±0.02 mm
Thickness, insulation
≥ 0.23 mm (Core insulation)
Thickness, insulation
≥ 0.38 mm (Outer cable sheath)
Thickness, insulation
approx. 3.5 mm ±0.1 mm (Inner sheath)
Wire colors
brown, blue, black
Overall twist
3 wires, twisted
External sheath, color
gray RAL 7001
External cable diameter D
4.4 mm ±0.2 mm
Smallest bending radius, fixed installation
22 mm
Smallest bending radius, movable installation
44 mm
Number of bending cycles
2000000
Bending radius
44 mm
Traversing path
5 m
Traversing rate
3 m/s
Cable weight
27 kg/km
Outer sheath, material
PUR
Material, inner sheath
PVC
Material conductor insulation
PVC
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 100 MΩ*km (at 20 °C)
Conductor resistance
max. 78 Ω/km (at 20 °C)
Nominal voltage, cable
≤ 300 V
Test voltage, cable
≥ 3000 V
Flame resistance
As per UL-Style 2464
Ambient temperature (operation)
-25 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-5 °C - 80 °C (cable, flexible installation)

Dimensions

Length of cable
Free input (0.2 - 40.0 m)

Material

Flammability rating according to UL 94
HB
Contact material
CuSn
Contact surface material
Ni/Au
Contact carrier material
TPU GF
Material of grip body
TPU, hardly inflammable, self-extinguishing
Material, knurls
Zinc die-cast, nickel-plated
Sealing material
NBR

PUR/PVC yellow [140]

Cable type
PUR/PVC yellow
Cable type (abbreviation)
140
Cable abbreviation
LiYY-11Y
UL AWM style
20549
Conductor cross section
0.25 mm²
AWG signal line
24
Conductor structure signal line
32x 0.10 mm
Core diameter including insulation
1.32 mm ±0.02 mm
Thickness, insulation
≥ 0.23 mm (Core insulation)
Thickness, insulation
≥ 0.38 mm (Outer cable sheath)
Thickness, insulation
approx. 0.35 mm (Inner sheath)
Wire colors
brown, blue, black
Overall twist
3 wires, twisted
External sheath, color
yellow
External cable diameter D
4.4 mm ±0.2 mm
Smallest bending radius, fixed installation
44 mm
Smallest bending radius, movable installation
44 mm
Number of bending cycles
2000000
Bending radius
44 mm
Traversing path
5 m
Traversing rate
3 m/s
Cable weight
27 kg/km
Outer sheath, material
PUR
Material, inner sheath
PVC
Material conductor insulation
PVC
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 100 MΩ*km (at 20 °C)
Conductor resistance
max. 78 Ω/km (at 20 °C)
Nominal voltage, cable
≤ 300 V
Test voltage, cable
≥ 3000 V
Flame resistance
in accordance with DIN UL-Style 20549
Ambient temperature (operation)
-25 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-5 °C - 80 °C (cable, flexible installation)

PUR halogen-free black [PUR]

Cable type
PUR halogen-free black
Cable type (abbreviation)
PUR
Cable abbreviation
Li9Y11Y-HF
UL AWM style
20549 / 10493 (80°C/300 V)
Conductor cross section
3x 0.25 mm²
AWG signal line
24
Conductor structure signal line
32x 0.10 mm
Core diameter including insulation
1.17 mm ±0.02 mm
Thickness, insulation
≥ 0.21 mm (Core insulation)
Wire colors
brown, blue, black
Overall twist
3 wires, twisted
Length of twist, overall twist
40 mm
External sheath, color
black-gray RAL 7021
Outer sheath thickness
approx. 0.5 mm
External cable diameter D
3.6 mm ±0.15 mm
Smallest bending radius, fixed installation
18 mm
Smallest bending radius, movable installation
36 mm
Number of bending cycles
10000000
Bending radius
44 mm
Traversing path
10 m
Traversing rate
3 m/s
Acceleration
10 m/s²
Cable weight
18 kg/km
Outer sheath, material
PUR
Material conductor insulation
PP
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 100 GΩ*km (at 20 °C)
Conductor resistance
≤ 78 Ω/km (at 20 °C)
Nominal voltage, cable
≤ 300 V
Test voltage, cable
≥ 3000 V
Special properties
Flexible cable conduit capable
Special properties
Silicone-free
Special properties
Free of substances which would hinder coating with paint or varnish
Flame resistance
in accordance with UL 758/1581 FT2
Flame resistance
DIN EN 60332-2-2 (20 s)
Halogen-free
in accordance with DIN VDE 0472 part 815
Resistance to oil
in accordance with DIN EN 60811-2-1
Other resistance
hydrolysis and microbe resistant
Other resistance
Highly resistant to acids, alkaline solutions and solvents
Other resistance
Resistant to salt water
Other resistance
partly UV-resistant in accordance with DIN EN ISO 4892-2-A
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-25 °C - 80 °C (cable, flexible installation)

PVC gray [500]

Cable type
PVC gray
Cable type (abbreviation)
500
Cable abbreviation
LiYY
Conductor cross section
0.25 mm²
AWG signal line
24
Conductor structure signal line
32x 0.10 mm
Core diameter including insulation
1.25 mm ±0.02 mm
Thickness, insulation
≥ 0.23 mm (Core insulation)
Thickness, insulation
≥ 0.76 mm (Outer cable sheath)
Wire colors
brown, blue, black
Overall twist
3 wires, twisted
External sheath, color
gray RAL 7001
External cable diameter D
4.4 mm ±0.15 mm
Cable weight
29 kg/km
Outer sheath, material
PVC
Material conductor insulation
PVC
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 1 GΩ*km (at 20 °C)
Conductor resistance
max. 78 Ω/km (at 20 °C)
Nominal voltage, cable
≥ 300 V
Test voltage, cable
≤ 3000 V
Flame resistance
As per UL-Style 2464
Ambient temperature (operation)
-25 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-5 °C - 80 °C (cable, flexible installation)

PUR halogen-free orange [180]

Cable type
PUR halogen-free orange
Cable type (abbreviation)
180
Cable abbreviation
Li9Y-11Y
UL AWM style
20549
Conductor cross section
3x 0.25 mm² (Signal line)
AWG signal line
24
Conductor structure signal line
32x 0.10 mm
Core diameter including insulation
1.17 mm ±0.02 mm (Signal line)
Thickness, insulation
≥ 0.21 mm (Core insulation)
Thickness, insulation
approx. 0.9 mm (Outer cable sheath)
Wire colors
brown, blue, black
Overall twist
3 wires, twisted
External sheath, color
orange RAL 2003
External cable diameter D
4.4 mm ±0.15 mm
Smallest bending radius, fixed installation
22 mm
Smallest bending radius, movable installation
44 mm
Number of bending cycles
4000000
Bending radius
44 mm
Traversing path
10 m
Traversing rate
3 m/s
Acceleration
10 m/s²
Cable weight
24 kg/km
Outer sheath, material
PUR
Material conductor insulation
PP
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 10 GΩ*km (at 20 °C)
Conductor resistance
max. 78 Ω/km (at 20 °C)
Nominal voltage, cable
≤ 300 V
Test voltage, cable
≥ 3000 V
Flame resistance
in accordance with DIN UL-Style 20549
Flame resistance
in accordance with UL 758/1581 FT2
Halogen-free
in accordance with DIN VDE 0472 part 815
Resistance to oil
in accordance with DIN EN 60811-2-1
Other resistance
hydrolysis and microbe resistant
Other resistance
Resistant to salt water
Ambient temperature (operation)
-40 °C - 80 °C (cable, fixed installation)
Ambient temperature (operation)
-25 °C - 80 °C (cable, flexible installation)

Ambient conditions

Ambient temperature (operation)
-25 °C - 90 °C (Plug / socket)
Degree of protection
IP65
Degree of protection
IP67
Degree of protection
IP68

Line characteristics

Note
This item is a sensor/actuator cable with a freely selectable cable type. The technical data for all possible cable types is listed in the table below.

Environmental Product Compliance

China RoHS
Environmentally friendly use period: unlimited = EFUP-e
China RoHS
No hazardous substances above threshold values

Standards and Regulations

Standards/specifications
M12 connector IEC 61076-2-101
Standards/specifications
M8 connector IEC 61076-2-104
Flammability rating according to UL 94
HB

Related products