1 / 1
thumbnail

Description

Attachment plug with surge protection for antenna inputs with TV connector
Country of Origin
DE
Part Number
2857002
Tariff Code
85363010
EAN
4017918915186
UPC
4017918915186
ETIM
Group Code : EG000021
Group Description : Earthing, lightning and surge protection
Class Description : Surge protection device for data networks/MCR-technology
Class Code : EC000943
Version : 7
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Dimensions

Height
40 mm
Width
28 mm
Depth
61 mm

Connection data

Connection method
PAL-TV (IEC 169-2)
Connection method IN
Socket
Connection method OUT
Male

Ambient conditions

Ambient temperature (operation)
-25 °C - 75 °C
Altitude
≤ 2000 m (amsl (above mean sea level))
Degree of protection
IP20

Protective circuit

IEC test classification
C1
IEC test classification
C2
IEC test classification
C3
IEC test classification
D1
Maximum continuous voltage UC
24 V DC
Rated current
1.5 A (25 °C)
Operating effective current IC at UC
≤ 1 µA
Residual current IPE
≤ 1 µA
Nominal discharge current In (8/20) µs (line-shield)
2.5 kA
Nominal pulse current Ian (10/1000) µs (line-shield)
120 A
Output voltage limitation at 1 kV/µs (line-shield) spike
≤ 600 V
Output voltage limitation at 1 kV/µs (line-shield) static
≤ 600 V
Residual voltage at In (line-shield)
≤ 30 V
Voltage protection level Up (line-shield)
≤ 700 V (C2 - 4 kV / 2 kA)
Voltage protection level Up (line-shield)
≤ 800 V (C2 - 5 kV/2,5 kA)
Response time tA (line-shield)
≤ 100 ns
Input attenuation aE, asym.
typ. 0.5 dB (≤ 2.4 GHz /75 Ω)
Cut-off frequency fg (3 dB), asym. (shield) in 75 Ohm system
> 1 GHz
Frequency range
4.7 MHz - 860 MHz
Capacity asymmetrical (shield)
typ. 10 pF
Surge protection fault message
none
Impulse durability (line-shield)
C2 - 4 kV/2 kA
Impulse durability (line-shield)
C2 - 5 kV / 2.5 kA
Impulse durability (line-shield)
C3 - 100 A
Impulse durability (line-shield)
D1 - 500 A
Alternating current carrying capacity (line-shield)
5 A - 1 s
Pulse reset time (line-shield)
< 3 s

Standards and Regulations

Standards/specifications
IEC 61643-21 2012
Standards/specifications
EN 61643-21 2013
Standards/specifications
EN 50083 CLASS-A

CAD Models

traceparts
traceparts
Download