SolaHD Części zamienne do automatyki przemysłowej

66 wyników

E500TH SolaHD, Akcesoria ogólne
SolaHD

E500TH

SBE Series Encapsulated Copper Wound Transformers - PN

W magazynie

The SBE Series encapsulated copper wound transformers are designed for industrial applications, featuring epoxy encapsulation that safeguards the cores and coils from moisture, dirt, and other contaminants. This design enhances durability and reliability in demanding environments.With a primary voltage range that includes configurations such as 120 x 240 Volt, 220 x 440 Volt, and 240 x 480 Volt, these transformers support multiple secondary voltage outputs, including 24 Volt and 120 Volt. The transformers are available with a KVA rating from 50 to 1000, accommodating various power needs.Additional features include extra deep, molded terminal barriers that minimize the risk of electrical failures due to arcing or frayed lead wires. The rugged construction of the SBE design is ideal for industrial control applications, ensuring longevity and consistent performance.

Dostępny w:
US
Ilość
  • Nieznany
    2 szt.
SDP124100T SolaHD, Zasilacze i sterowniki mocy
SolaHD

SDP124100T

SolaHD™ SDP Low Power DIN Rail Series Power Supplies - PN SDP124100T

W magazynie

SDP™ Low Power DIN Rail Series Power Supplies provide efficient power from 5 to 48 Vdc and up to 100 Watts in a choice of compact, lightweight DIN rail mounted units. These affordable power supplies offer the exceptional reliability and advanced features required for industrial use. PowerBoost™ overload circuitry starts up industrial loads that can cause ordinary power supplies to foldback or shutdown.

Dostępny w:
US
Ilość
  • Nieznany
    4 szt.
  • Nowy Fabrycznie Zapakowany
    3 szt.
SDP424100RT SolaHD, Zasilacze i sterowniki mocy
SolaHD

SDP424100RT

SolaHD™ SDP Low Power DIN Rail Series Power Supplies - PN SDP424100RT

W magazynie

SDP™ Low Power DIN Rail Series Power Supplies provide efficient power from 5 to 48 Vdc and up to 100 Watts in a choice of compact, lightweight DIN rail mounted units. These affordable power supplies offer the exceptional reliability and advanced features required for industrial use. PowerBoost™ overload circuitry starts up industrial loads that can cause ordinary power supplies to foldback or shutdown.

Dostępny w:
CZ
FR
DE
IT
LV
NL
+5 dostawców
Ilość
  • Nowy Fabrycznie Zapakowany
    118 szt.
  • Nowy, Rynek wtórny
    1 szt.
E750TH SolaHD, Zasilacze i sterowniki mocy
SolaHD

E750TH

SolaHD™ International Series Control Transformers - PN E750TH

W magazynie

Electromagnetic control components demand inrush currents up to 10 times the transformer's nominal rating without sacrificing secondary voltage stability beyond practical limits. International Series transformers fully comply with IEC and NEMA standards and are available with IEC touchproof covers (IP20).

Dostępny w:
CZ
FR
DE
IT
LV
NL
+5 dostawców
Ilość
  • Nowy, Rynek wtórny
    3 szt.
  • Nowy Fabrycznie Zapakowany
    3 szt.
SDP224100T SolaHD, Zasilacze i sterowniki mocy
SolaHD

SDP224100T

SolaHD™ SDP Low Power DIN Rail Series Power Supplies - PN SDP224100T

W magazynie

SDP™ Low Power DIN Rail Series Power Supplies provide efficient power from 5 to 48 Vdc and up to 100 Watts in a choice of compact, lightweight DIN rail mounted units. These affordable power supplies offer the exceptional reliability and advanced features required for industrial use. PowerBoost™ overload circuitry starts up industrial loads that can cause ordinary power supplies to foldback or shutdown.

Dostępny w:
CZ
FR
DE
IT
LV
NL
+5 dostawców
Ilość
  • Nowy Fabrycznie Zapakowany
    62 szt.
  • Nowy, Rynek wtórny
    8 szt.
+1 stan
SDP55100T SolaHD, Zasilacze i sterowniki mocy
SolaHD

SDP55100T

SolaHD™ SDP Low Power DIN Rail Series Power Supplies - PN SDP55100T

W magazynie

SDP™ Low Power DIN Rail Series Power Supplies provide efficient power from 5 to 48 Vdc and up to 100 Watts in a choice of compact, lightweight DIN rail mounted units. These affordable power supplies offer the exceptional reliability and advanced features required for industrial use. PowerBoost™ overload circuitry starts up industrial loads that can cause ordinary power supplies to foldback or shutdown.

Dostępny w:
CZ
FR
DE
IT
LV
NL
+5 dostawców
Ilość
  • Nowy Fabrycznie Zapakowany
    26 szt.
  • Nowy, Rynek wtórny
    5 szt.
+1 stan
SDN2024100C SolaHD, Zasilacze i sterowniki mocy
SolaHD

SDN2024100C

SolaHD™ SDN-C Performance DIN Rail Series Power Supplies - PN SDN2024100C

W magazynie

High performance specifications and extensive international certifications ensure that the SDN-C is suitable for the most extreme environments, including hazardous locations and off-shore applications. Features like wide operating temperature range, power boost capability, and adjustable output voltage ensure reliable operation in the harshest industrial environments. Parallel operation, extensive LED diagnostics, and universal AC or DC input voltage simplify installation and maintenance. For added reliability, the SDN-C power supplies can be used with the SolaHD™ Redundancy modules to provide redundant power supply operation.

Dostępny w:
CA
CZ
FR
DE
IT
LV
+6 dostawców
Ilość
  • Nowy Fabrycznie Zapakowany
    57 szt.
  • Nowy, Rynek wtórny
    5 szt.
+2 stany
SDN2524100P SolaHD, Zasilanie
SolaHD

SDN2524100P

SolaHD™ SDN-P DIN Rail Series Power Supplies - PN SDN2524100P

W magazynie

SDN-P™ DIN rail power supplies provide sag immunity, transient suppression and noise tolerance to handle the most demanding applications. Power factor correction meets European directives, while hazardous location approvals and optional redundant accessories provide the flexibility to suit a wide range of application needs and environments. SDN-P DIN rail power supplies have a wide operational temperature range, high tolerance to shock and vibration and a rugged design.

Dostępny w:
CZ
FR
DE
IT
LV
NL
+5 dostawców
Ilość
  • Nowy Fabrycznie Zapakowany
    237 szt.
  • Nowy, Rynek wtórny
    25 szt.
+2 stany
SDU1024 SolaHD, Zasilanie
SolaHD

SDU1024

DIN Rail DC UPS System - PN

Na zamówienie

The DIN Rail DC UPS System - PN SDU1024 serves as a critical backup power solution designed to efficiently convert both DC and AC power. Unlike conventional systems that may unnecessarily convert power multiple times, this model minimizes inefficiencies, ensuring enhanced system uptime and reliability. Specifically, the SDU 10-24 model delivers a power rating of 240 VA with an output of 24V at 10A, while the SDU 20-24 model offers 480 VA at 24V and 20A. Typical backup times are significant, with the 10 Amp load supporting up to 14 minutes and the 20 Amp load sustaining for 4 minutes. Operating in a temperature range of -20°C to +50°C, this UPS system maintains functionality across a variety of environments. Moreover, the input voltage range is between 22.5 to 30 Vdc, and the output voltage range mirrors this, ensuring compatibility with multiple applications. The system is designed for DIN rail mounting, fitting TS35/7.5 or TS35/15, or can be chassis-mounted for versatile installation options. The audible noise level remains below 40dBA at a distance of one meter, contributing to a quieter operational environment.

Dostępny w:
GB
Poproś o wycenę
SLS15045T SolaHD, Zasilanie
SolaHD

SLS15045T

SL Series Single and Multi Output Power Supplies - PN

Na zamówienie

The SL Series power supplies support a range of input voltages including 100/120/220/230/240 Vac, selectable to accommodate various applications. Designed for chassis mounting, these power supplies operate at frequencies of 47-63 Hz and are rated for an output power of 15-244 W. Each unit delivers an output voltage range of 15 to 34 Vdc, depending on the specific model. The operating temperature range extends from 0°C to +50°C, ensuring reliable performance in diverse environments. Safety features include standard screw terminal connections and optional covers to enhance user protection. The overload capability is managed through an automatic current limit foldback mechanism, providing additional operational safety.

Poproś o wycenę
HTS6F9AS SolaHD, Akcesoria ogólne
SolaHD

HTS6F9AS

Automation Transformers Non Ventilated 50 VA to 45 kVA - PN

Na zamówienie

These automation transformers are engineered for non-ventilated applications, offering power ratings from 50 VA to 45 kVA. Their encapsulated design ensures protection in hazardous locations as well as in harsh industrial environments. The rugged NEMA 3R enclosures guard against dust and moisture ingress, while providing enhanced shock and vibration resistance. UL Listed, these transformers meet the latest edition of the National Electrical Code for Class I, Division 2, Group A-D locations when installed in accordance with NEC 501.100(B). They are available in both single and three-phase configurations and utilize aluminum windings. With frequency options of 50 or 60 Hz, these transformers are suitable for a variety of industrial applications, ensuring reliable performance under demanding conditions.

Poproś o wycenę
HS19F1B SolaHD, Akcesoria ogólne
SolaHD

HS19F1B

Buck-Boost Transformers - PN

Na zamówienie

Buck-Boost Transformers are engineered to offer a compact and energy-efficient solution for voltage adjustment. These transformers can increase or decrease voltage by a small margin, typically between 5 to 27 percent, making them ideal for applications where the voltage requirements differ from the available line voltage. They are particularly effective for powering control panels and landscape lighting, ensuring optimal performance and longevity of the connected equipment. These transformers come in various specifications, including a primary voltage of 120 x 240 Volts with secondary options of 12/24 Volts. They are available in both non-encapsulated and encapsulated designs, accommodating frequencies of either 50/60 Hz or 60 Hz. The non-encapsulated variants are rated at 0.05, 0.1, 0.15, and 0.25 kVA, while the encapsulated models range from 0.5 to 7.5 kVA. Additionally, configurations with a primary voltage of 240 x 480 Volts and secondary options of 24/48 Volts are also available. These transformers utilize aluminum windings and are designed for single-phase applications, providing reliable voltage modification for a variety of loads.

Dostępny w:
CZ
FR
DE
IT
NL
PL
+4 dostawcy
Poproś o wycenę
E150EW SolaHD, Akcesoria ogólne
SolaHD

E150EW

SBE Series Encapsulated Copper Wound Transformers - PN

Na zamówienie

The SBE Series encapsulated copper wound transformers are specifically designed for industrial applications, featuring epoxy encapsulation that safeguards the cores and coils from moisture, dirt, and other contaminants. This construction ensures durability and reliability in challenging environments.These transformers support various primary voltage configurations, including 120 x 240 Volts and 220 x 440 Volts, with secondary outputs of 24 Volts, 110 Volts, and 120 Volts, operating at frequencies of 50/60 Hz. The transformers are available in a range of continuous VA ratings, from 50 to 1000 VA, accommodating diverse power requirements.Additionally, the transformers are equipped with extra deep, molded terminal barriers that minimize the risk of electrical failures caused by arcing or damaged lead wires. The use of copper windings contributes to their efficiency, while their steel mounting plate facilitates stable installation. With a temperature rise of +55°C, these transformers are well-suited for demanding industrial settings.

Dostępny w:
US
Poproś o wycenę
S4K288INTBATC SolaHD, Zasilanie
SolaHD

S4K288INTBATC

S4K4U-C 6 kVA and S4K6U-C 10 kVA Industrial On-Line UPS - PN

Na zamówienie

The S4K4U-C 6 kVA and S4K6U-C 10 kVA Industrial On-Line UPSs are engineered to deliver reliable power protection through double conversion topology, effectively safeguarding against a variety of power disturbances. The units are housed in a space-efficient 4U (7.0") or 6U (10.5") form factor, making them suitable for environments where space is a premium. These UPS systems support an input voltage range of 120/208 Vac and can operate within nominal voltage levels of 120/208 Vac. They are capable of functioning at a frequency of either 50 or 60 Hz, ensuring compatibility with various electrical systems. The systems offer a typical backup time of 4 minutes at full load for the 6 kVA model and 5 minutes for the 10 kVA model, providing critical power support during outages. With an operating temperature range from 0°C to +40°C, these UPSs are designed for a wide range of industrial applications. The audible noise levels are maintained below 55 dBA at a distance of 3.2 feet from the rear and below 50 dBA from the front and sides, ensuring minimal disruption in work environments.

Poproś o wycenę
WSS11 SolaHD, Zasilanie
SolaHD

WSS11

General Purpose Ventilated Transformers - PN

Na zamówienie

The General Purpose Ventilated Transformers, designated as PN WSS11, are engineered for 600 Volt Class applications, featuring a dry type construction that classifies them as isolation transformers. These transformers facilitate both step-up and step-down voltage conversions and are available in a variety of models suitable for indoor and outdoor installations.Configurations include single-phase options with primary voltages of 240 x 480 Volt and 120/208/240/277 Volt, supporting secondary outputs of 120/240 Volt. Three-phase models are offered with primary voltages of 480 Volt ∆, providing secondary outputs of 208/120 Volt, 240 Volt ∆, and 480Y/277 Volt, among others, with power ratings from 15 kVA to 500 kVA. The transformers are designed to operate at a frequency of 60 Hz and can be equipped with either aluminum or copper windings. The temperature rise during operation is rated at +150°C.

Poproś o wycenę
E2H30S SolaHD, Przekładnie i reduktory
SolaHD

E2H30S

General Purpose Ventilated Transformers - PN

Na zamówienie

The General Purpose Ventilated Transformers, classified as isolation transformers, are designed for applications requiring reliable voltage transformation. Operating within a 600 Volt Class, these transformers are available in both single-phase and three-phase configurations, providing versatility for indoor and outdoor installations.In terms of specifications, the single-phase models support primary voltages of 240 x 480 volts with secondary outputs of 120/240 volts, available in capacities ranging from 15 kVA to 100 kVA. Additionally, for three-phase applications, options include configurations with primary voltages of 480 volts Δ and 208/120 volts secondary, covering capacities from 15 kVA to 500 kVA. The transformers can accommodate various voltage combinations, including 480Y/277 and 208Y/120, ensuring adaptability to different circuit configurations.With a temperature rise rated at +150°C and options for aluminum or copper windings, these transformers are engineered to meet demanding operational conditions. Designation Code: E2H30S

Poproś o wycenę
63TCA330 SolaHD, Zasilanie
SolaHD

63TCA330

Three Phase Power Conditioner - PN

Na zamówienie

The Three Phase Power Conditioner - PN 63TCA330 is designed to safeguard equipment from chronic over and under voltage conditions, switching transients, lightning strikes, and induced surges. It integrates a surge suppression circuit with a shielded isolation transformer to maintain stable operations.This unit ensures output voltage regulation to ±3% even when input voltage fluctuates between +10% and -25%. The device is responsive to any line variation, with a swift response time of just 1.5 cycles, independent of the power factor.Standard input voltages include 208 Vac, 480 Vac, and 600 Vac, with various output configurations, including 208Y/120 Vac and 480Y/277 Vac. It supports load capacities ranging from 20 to 75 kVA, with an efficiency rating of up to 96% at full load. The operational temperature range is from 0°C to +40°C, and the unit features an overload capability for rated loads of 1000% for 1 second and 200% for 1 minute. Status indicators include over temperature, bypass, and regulated output present.

Dostępny w:
US
Poproś o wycenę
E050JL SolaHD, Akcesoria ogólne
SolaHD

E050JL

Encapsulated Copper Wound Transformer - PN

Na zamówienie

The encapsulated copper wound transformer, designated as PN E050JL, is designed for industrial control applications. It is epoxy encapsulated, providing protection against moisture, dirt, and various industrial contaminants. The transformer features extra deep, molded terminal barriers to minimize the risk of electrical failure due to arcing or frayed lead wires. Its rugged construction ensures reliable operation in demanding environments.With a versatile configuration, this transformer supports multiple primary voltages including 120 x 240, 220 x 440, and 240 x 480 Volts, and offers secondary voltage options of 24, 110, and 115 Volts. The product operates at both 50 and 60 Hz with continuous VA ratings available from 50 to 1000, catering to a range of load requirements. Additionally, the temperature rise is rated at +55°C, and it is equipped with copper windings mounted on a steel plate, making it suitable for various industrial applications.

Dostępny w:
US
Poproś o wycenę
K4E2H45S SolaHD, Akcesoria ogólne
SolaHD

K4E2H45S

K-Factor Ventilated Transformers - PN

Na zamówienie

The K-Factor Ventilated Transformers are engineered to accommodate harmonic currents generated by non-linear loads, preventing overheating and premature failure. This design aspect is critical as standard transformers may not withstand the added losses associated with such loads. The transformers incorporate a core and coil structure that effectively manages DC flux produced by triplen harmonics, ensuring stable operation. With a K-4 rating, these transformers operate with a 480 ∆ primary and a 208Y/120 secondary configuration, available in various capacities ranging from 15 kVA to 500 kVA. The windings are constructed from aluminum, contributing to their reliability in performance.This model operates at a frequency of 60 Hz and is configured for three-phase applications with a temperature rise rating of +150°C, which is essential for maintaining optimal operational conditions.

Poproś o wycenę
E250EWB SolaHD, Akcesoria ogólne
SolaHD

E250EWB

Encapsulated Copper Wound Transformers - PN

Na zamówienie

The encapsulated copper wound transformers in the SBE Series are specifically designed for industrial control applications, providing multiple voltage configurations to suit various operational needs. With a primary voltage range including 120 x 240 Volt, 220 x 440 Volt, and 240 x 480 Volt among others, these transformers are capable of delivering secondary voltages of 24 Volt, 110 Volt, 115 Volt, and 120 Volt.These transformers feature epoxy encapsulation, offering enhanced protection for the cores and coils against moisture, dirt, and industrial contaminants. This construction reduces the risk of electrical failure due to arcing or frayed lead wires, thanks to the extra deep, molded terminal barriers. The SBE design, with a temperature rise rating of +55°C, is well-suited for demanding industrial environments, ensuring reliability and longevity.With KVA ratings available from 50 to 750, including continuous VA options, this series accommodates diverse power requirements. The windings are constructed of copper, mounted on a steel mounting plate, providing a robust solution for various applications.

Dostępny w:
US
Poproś o wycenę