analog isolated low level input module, Modicon X80, 4 inputs, 40mV positive or negative
BMXART0414
BMXART0414
BMXART0414
BMXART0414
BMXART0414
  • Termin płatności do 90 dni od 500+ dostawców.
  • Rabaty na odsprzedaż do 40%!
Zarejestruj się
€471.29
1
Metody płatności:
Łącznie 135 części w magazynie od 37 dostawców

Additional Information

Part Number
BMXART0414
UNSPSC
32151705
Tariff Code
8538908180
Country of Origin
FR

Environment

Product Certifications
EAC || RCM || UL || Merchant Navy || CSA || CE
Ambient Air Temperature For Operation
0-60 °C
Standards
EN 61131-2 || EN 61000-6-4 || EN 61000-6-2 || EN 61010-2-201
Shock Resistance
30 gn
Vibration Resistance
3 gn
Directives
2014/35/EU - low voltage directive || 2014/30/EU - electromagnetic compatibility
Ambient Air Temperature For Storage
-40-85 °C
Relative Humidity
5-95 % 55-55 °C without condensation
Ip Degree Of Protection
IP20

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Complementary

Mtbf Reliability
1400000 H
Measurement Error
+/- 0.7 °C Ni 1000 25 °C || +/- 1.3 °C Ni 1000 0...60 °C || +/- 2 °C Pt 100 0...60 °C || +/- 2 °C Pt 1000 0...60 °C || +/- 2.1 °C Ni 100 25 °C || +/- 2.1 °C Pt 100 25 °C || +/- 2.1 °C Pt 1000 25 °C || +/- 2.7 °C thermocouple U 25 °C || +/- 2.8 °C thermocouple J 25 °C || +/- 3 °C Ni 100 0...60 °C || +/- 3 °C thermocouple L 25 °C || +/- 3.2 °C thermocouple R 25 °C || +/- 3.2 °C thermocouple S 25 °C || +/- 3.5 °C thermocouple B 25 °C || +/- 3.7 °C thermocouple E 25 °C || +/- 3.7 °C thermocouple K 25 °C || +/- 3.7 °C thermocouple N 25 °C || +/- 3.7 °C thermocouple T 25 °C || +/- 4 °C Cu 10 0...60 °C || +/- 4 °C Cu 10 25 °C || +/- 4.5 °C thermocouple J 0...60 °C || +/- 4.5 °C thermocouple L 0...60 °C || +/- 4.5 °C thermocouple R 0...60 °C || +/- 4.5 °C thermocouple S 0...60 °C || +/- 4.5 °C thermocouple U 0...60 °C || +/- 5 °C thermocouple B 0...60 °C || +/- 5 °C thermocouple E 0...60 °C || +/- 5 °C thermocouple K 0...60 °C || +/- 5 °C thermocouple N 0...60 °C || +/- 5 °C thermocouple T 0...60 °C || <= 0.15 % of full scale +/- 1.28 V 0...60 °C || <= 0.15 % of full scale +/- 160 mV 0...60 °C || <= 0.15 % of full scale +/- 320 mV 0...60 °C || <= 0.15 % of full scale +/- 40 mV 0...60 °C || <= 0.15 % of full scale +/- 640 mV 0...60 °C || <= 0.15 % of full scale +/- 80 mV 0...60 °C || <= 0.2 % of full scale 400 Ohm 0...60 °C || <= 0.2 % of full scale 4000 Ohm 0...60 °C || 0.05 % of full scale +/- 1.28 V 25 °C || 0.05 % of full scale +/- 160 mV 25 °C || 0.05 % of full scale +/- 320 mV 25 °C || 0.05 % of full scale +/- 40 mV 25 °C || 0.05 % of full scale +/- 640 mV 25 °C || 0.05 % of full scale +/- 80 mV 25 °C || 0.12 % of full scale 400 Ohm 25 °C || 0.12 % of full scale 4000 Ohm 25 °C
Maximum Conversion Value
+/- 100 % 400 Ohm || +/- 100 % 4000 Ohm || +/- 102.5 % +/- 1.28 V || +/- 102.5 % +/- 160 mV || +/- 102.5 % +/- 320 mV || +/- 102.5 % +/- 40 mV || +/- 102.5 % +/- 640 mV || +/- 102.5 % +/- 80 mV
Type Of Filter
first order digital filtering
Status Led
1 LED (Green) RUN || 1 LED per channel (Green) channel diagnostic || 1 LED (Red) ERR || 1 LED (Red) I/O
Temperature Drift
25 ppm/°C 400 Ohm || 25 ppm/°C 4000 Ohm || 25 ppm/°C Ni 1000 || 25 ppm/°C thermocouple B || 25 ppm/°C thermocouple E || 25 ppm/°C thermocouple J || 25 ppm/°C thermocouple K || 25 ppm/°C thermocouple L || 25 ppm/°C thermocouple N || 25 ppm/°C thermocouple R || 25 ppm/°C thermocouple S || 25 ppm/°C thermocouple T || 25 ppm/°C thermocouple U || 30 ppm/°C +/- 1.28 V || 30 ppm/°C +/- 160 mV || 30 ppm/°C +/- 320 mV || 30 ppm/°C +/- 40 mV || 30 ppm/°C +/- 640 mV || 30 ppm/°C +/- 80 mV || 30 ppm/°C Cu 10 || 30 ppm/°C Ni 100 || 30 ppm/°C Pt 100 || 30 ppm/°C Pt 1000
Recalibration
internal
Cold Junction Compensation
external by Pt100 probe
Current Consumption
150 mA 3.3 V DC || 40 mA 24 V DC
Analogue Input Resolution
15 bits + sign
Net Weight
0.135 kg
Isolation Voltage
1400 V DC between channels and bus || 750 V DC between channels || 750 V DC between channels and ground
Differential Mode Rejection
60 dB 50/60 Hz
Nominal Read Cycle Time
400 ms with temperature probe || 200 ms with thermocouple
Detection Type
open circuit Cu 10 || open circuit Ni 100 || open circuit Ni 1000 || open circuit Pt 100 || open circuit Pt 1000 || open circuit thermocouple B || open circuit thermocouple E || open circuit thermocouple J || open circuit thermocouple K || open circuit thermocouple L || open circuit thermocouple N || open circuit thermocouple R || open circuit thermocouple S || open circuit thermocouple T || open circuit thermocouple U
Maximum Wiring Resistance
20 Ohm 2 wires Cu 10 || 20 Ohm 2 wires Ni 100 || 20 Ohm 2 wires Pt 100 || 20 Ohm 3 wires Cu 10 || 20 Ohm 3 wires Ni 100 || 20 Ohm 3 wires Pt 100 || 200 Ohm 2 wires Ni 1000 || 200 Ohm 2 wires Pt 1000 || 200 Ohm 3 wires Ni 1000 || 200 Ohm 3 wires Pt 1000 || 50 Ohm 4 wires Cu 10 || 50 Ohm 4 wires Ni 100 || 50 Ohm 4 wires Pt 100 || 500 Ohm 4 wires Ni 1000 || 500 Ohm 4 wires Pt 1000
Operating Altitude
0...6561.68 ft (0...2000 m) || 2000...5000 m with derating factor
Common Mode Rejection
120 dB 50/60 Hz
Analog/Digital Conversion
sigma delta 16 bits
Measurement Resolution
0.1 °C Cu 10 || 0.1 °C Ni 100 || 0.1 °C Ni 1000 || 0.1 °C Pt 100 || 0.1 °C Pt 1000 || 0.1 °C thermocouple B || 0.1 °C thermocouple E || 0.1 °C thermocouple J || 0.1 °C thermocouple K || 0.1 °C thermocouple L || 0.1 °C thermocouple N || 0.1 °C thermocouple R || 0.1 °C thermocouple S || 0.1 °C thermocouple T || 0.1 °C thermocouple U || 1280/2exp14 mV +/- 1.28 V || 160/2exp14 mV +/- 160 mV || 320/2exp14 mV +/- 320 mV || 40/2exp14 mV +/- 40 mV || 12.5 mOhm 400 Ohm || 125 mOhm 4000 Ohm || 640/2exp14 mV +/- 640 mV || 80/2exp14 mV +/- 80 mV
Permitted Overload On Inputs
+/- 7.5 V +/- 1.28 V || +/- 7.5 V +/- 160 mV || +/- 7.5 V +/- 320 mV || +/- 7.5 V +/- 40 mV || +/- 7.5 V +/- 640 mV || +/- 7.5 V +/- 80 mV

Specifications

Range Of Product
Modicon X80
Product Or Component Type
analog input module
Input Level
low level
Electrical Connection
40 ways 1 connector
Input Output Isolation
isolated
Analogue Input Number
4
Analogue Input Type
voltage +/- 1.28 V || voltage +/- 160 mV || voltage +/- 320 mV || voltage +/- 40 mV || voltage +/- 640 mV || voltage +/- 80 mV || resistor 400 Ohm 2 wires || resistor 400 Ohm 3 wires || resistor 400 Ohm 4 wires || resistor 4000 Ohm 2 wires || resistor 4000 Ohm 3 wires || resistor 4000 Ohm 4 wires || temperature probe -100...+260 °C Cu 10 || temperature probe -100...+450 °C Pt 100 UL/JIS || temperature probe -100...+450 °C Pt 1000 UL/JIS || temperature probe -200...+850 °C Pt 100 IEC || temperature probe -200...+850 °C Pt 1000 IEC || temperature probe -60...+180 °C Ni 100 || temperature probe -60...+180 °C Ni 1000 || thermocouple +130...+1820 °C thermocouple B || thermocouple +270...+1300 °C thermocouple N || thermocouple -200...+600 °C thermocouple U || thermocouple -200...+760 °C thermocouple J || thermocouple -200...+900 °C thermocouple L || thermocouple -270...+1000 °C thermocouple E || thermocouple -270...+1370 °C thermocouple K || thermocouple -270...+400 °C thermocouple T || thermocouple -50...+1769 °C thermocouple R || thermocouple -50...+1769 °C thermocouple S

Dokumenty

Data Sheet

Pobierz

Modele CAD

Części śladowe
Części śladowe
Pobierz

Powiązane produkty