Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 100kA, thermal magnetic, Everlink terminals
GV4PE115S
  • Termin płatności do 90 dni od 500+ dostawców.
  • Rabaty na odsprzedaż do 40%!
Zarejestruj się
Wyślij zapytanie o cenę
1
Metody płatności:

Additional Information

Part Number
GV4PE115S
Tariff Code
8536200020

Environment

Product Certifications
IEC || UL || CSA || CCC || EAC || ATEX || EU-RO MR
Ik Degree Of Protection
IK07 IEC 62262
Ambient Air Temperature For Operation
-25-70 °C
Standards
CSA C22.2 No 60947-4-1 || UL 60947-4-1 || EN/IEC 60947-4-1 || EN/IEC 60947-2
Climatic Withstand
IACS E10
Pollution Degree
3
Ambient Air Temperature For Storage
-50-85 °C
Ip Degree Of Protection
IP40 IEC 60529
Operating Altitude
5000 m
Fire Resistance
960 °C IEC 60695-2-11

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1704004EN
Sustainable Offer Status
Green Premium product
Pvc Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile
ENVEOLI1704004EN
Eu Rohs Directive
Compliant with Exemptions
Halogen Content Performance
Halogen free plastic parts product

Complementary

Mechanical Robustness
vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 || vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 || shocks 15 gn 11 ms IEC 60068-2-27
Line Rated Current
115 A
[Ue] Rated Operational Voltage
690 V AC 50/60 Hz IEC 60947-2
Height
155 mm
Phase Failure Sensitivity
yes IEC 60947-4-1
Rated Duty
continuous IEC 60947-4-1
Magnetic Tripping Current
1955-1955 A
[Ith] Conventional Free Air Thermal Current
115 A IEC 60947-4-1
Motor Power Kw
37-37 kW 400...415 V AC 50/60 Hz || 45-45 kW 400...415 V AC 50/60 Hz || 55-55 kW 400...415 V AC 50/60 Hz || 45-45 kW 500 V AC 50/60 Hz || 55-55 kW 500 V AC 50/60 Hz || 75-75 kW 500 V AC 50/60 Hz || 75-75 kW 660...690 V AC 50/60 Hz || 90-90 kW 660...690 V AC 50/60 Hz || 110-110 kW 660...690 V AC 50/60 Hz
Maximum Operating Rate
25 cyc/h
Operating Position
any position
Connections - Terminals
EverLink BTR screw connectors top) 1 1.5-70 mm² - solid || EverLink BTR screw connectors top) 1 1.5-50 mm² - flexible || EverLink BTR screw connectors bottom) 1 2.5-95 mm² - solid || EverLink BTR screw connectors bottom) 1 2.5-70 mm² - flexible
Utilisation Category
category A IEC 60947-2 || AC-3 IEC 60947-4-1
Net Weight
1.45 kg
[Uimp] Rated Impulse Withstand Voltage
8 kV IEC 60947-2
Control Type
toggle
Power Dissipation Per Pole
4.6 W
Electrical Durability
10000 cycles AC-3 440 V In/2 || 5000 cycles AC-3 440 V In
Breaking Capacity
120 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 || 70 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 30 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 18 kA Icu 525 V AC 50/60 Hz IEC 60947-2 || 100 kA 208Y/120 V AC 50/60 Hz UL 60947 || 100 kA 240 V AC 50/60 Hz UL 60947 || 65 kA 480Y/277 V AC 50/60 Hz UL 60947 || 10 kA Icu 660...690 V AC 50/60 Hz IEC 60947-2 || 25 kA 600Y/347 V AC 50/60 Hz UL 60947
Suitability For Isolation
yes IEC 60947-1
[Ui] Rated Insulation Voltage
800 V AC 50/60 Hz IEC 60947-2
Tightening Torque
9 N.m 16-95 mm² || 5 N.m 1.5-10 mm²
Mechanical Durability
40000 cycles
Poles Description
3P
Color
Gray RAL 7016)
Width
81 mm
Depth
116 mm

Specifications

Range Of Product
TeSys GV4
Product Or Component Type
motor circuit breaker
Product Name
TeSys GV4 || TeSys Deca
Range
TeSys Deca
Device Application
motor protection
Device Short Name
GV4PE
Trip Unit Technology
thermal-magnetic || electronic

Dokumenty

Data Sheet

Pobierz

Modele CAD

Części śladowe
Części śladowe
Pobierz

Powiązane produkty