IEC Contactor, TeSys Deca, Nonreversing, 40A, 30HP at 480VAC, up to 100kA SCCR, 3 Phase, 3 NO, 400VAC 50/60Hz Coil, Open

1 / 1
Schneider Electric LC1D40AV7 IEC Contactor, TeSys Deca, Nonreversing, 40A, 30HP at 480VAC, up to 100kA SCCR, 3 Phase, 3 NO, 400VAC 50/60Hz Coil, Open — Elektronika i płytki PCB
Zdjęcie katalogowe producenta

Opis produktu

Status Cyklu Życia:

The TeSys D contactor is an ideal solution for creating motor starters for diverse applications. This 40A inductive 3 pole IEC contactor can be mounted on a DIN rail or directly on a panel. The contactor boasts both Horsepower and Kw motor ratings, ensuring international acceptance.

This contactor is rated for 10HP at 200 to 208VAC, 10HP at 240VAC, 30HP at 480VAC, and 30HP at 600VAC in three-phase applications. For single-phase use, it is rated for 3HP at 115VAC and 5HP at 240VAC.

When paired with a 480VAC up to 110A circuit breaker or an up to 600VAC 90A Class J or CC fuse, this contactor can handle short-circuit currents of up to 100kA. The contactor comes with a 400 VAC 50/60 Hz coil and includes one normally open and one normally closed auxiliary contact as standard.

The contactor measures 4.80 inches in height, 2.17 inches in width, and 4.72 inches in depth, weighing 1.87 lbs. It is certified to UL, CSA, IEC, CCC, EAC, and Marine standards and meets the requirements of RoHS/REACh, making it a Green Premium product.

Wyślij zapytanie
Metody płatności:

Szczegóły oferty

Najlepsza oferta od:
Zaufany dostawca — Wielka Brytania, członek od 2023
Dostępność:
1 szt.
W magazynie
Zaktualizowano: 05-09-2026
Gwarancja:
12 miesięcy
Stan produktu:
Nowy, Rynek wtórny
Nowy, Rynek wtórny - Nowy, nieużywany, nieuszkodzony przedmiot bez gwarancji producenta. Przedmiot może być dostarczony bez oryginalnego opakowania lub w zastępczym opakowaniu. Jeśli dostarczono, pudełko mogło zostać otwarte.
Sprzedawca jest odpowiedzialny za wysyłkę produktu i wystawienie faktury

Specyfikacje

Product Certifications
GOST || CSA || UL || CCC
Standards
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
Climatic Withstand
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Flame Retardance
V1 conforming to UL 94
Protective Treatment
THIEC 60068-2-30
Ip Degree Of Protection
IP20 front face IEC 60529

Dostępne Oferty

(6)
LC1D40AV7 Schneider Electric, Elektronika i płytki PCB

Schneider Electric

Dostępność:
1 szt.
Na zamówienie
Zaktualizowano: 22-08-2026
Oferta od:
Zaufany dostawca — Rumunia, członek od 2023, 1–4 pracowników
LC1D40AV7 Schneider Electric, Elektronika i płytki PCB

Schneider Electric

Dostępność:
1 szt.
W magazynie
Zaktualizowano: 04-09-2026
Oferta od:
Zaufany dostawca — Niemcy, członek od 2024
Gwarancja:
24 miesiące
LC1D40AV7 Schneider Electric, Elektronika i płytki PCB

Schneider Electric

Dostępność:
3 szt.
W magazynie
Zaktualizowano: 05-09-2026
Oferta od:
Zaufany dostawca — Polska, członek od 2023, 50–99 pracowników
Gwarancja:
24 miesiące

Uzyskaj dostęp do naszej platformy, aby znaleźć więcej ofert

Zarejestruj się teraz, aby poznać 36 milionów ofert od zweryfikowanych dostawców z całego świata.W tym 2 więcej ofert dla tego produktu.

  • Porównaj oferty na całym świecie
  • Bezpośredni kontakt z dostawcą
  • Zapytania ofertowe, wyceny i zamówienia
  • Wyszukiwanie BOM
Zarejestruj sięDostępny jest bezpłatny 14-dniowy okres próbny
Oferta z czasem realizacji przez producenta
Bezpośrednio od producenta - z potwierdzonym, przewidywalnym i w pełni transparentnym czasem dostawy.
Uzyskaj wycenę

Dokumenty

Karta katalogowa

Karta katalogowa dla Schneider Electric LC1D40AV7, w tym specyfikacje i funkcje.

Pobierz arkusz danych
TracePartsTraceParts

Modele CAD

Model 3D CAD i rysunki techniczne, gotowe do Twojego oprogramowania projektowego.

Pobierz model CAD

Kompatybilne produkty

GV3G264 Schneider Electric
GV3G264
Schneider Electric
TeSys GV busbar set, 3 phases, rated for 115A at 690V, designed for upstream parallel wiring of motor starters using GV3 motor circuit breakers.
LAD4CM Schneider Electric
LAD4CM
Schneider Electric
TeSys D mechanical interlock, for contactors LC1D40A-D80A and LC1DT60A-DT80A
LAD4RC3N Schneider Electric
LAD4RC3N
Schneider Electric
TeSys D suppressor module, for LC1D40A-D80A, LC1DT60A-DT80A contactors
LAD8N02 Schneider Electric
LAD8N02
Schneider Electric
TeSys Deca instantaneous auxiliary contact block, for LC
LAD8N11 Schneider Electric
LAD8N11
Schneider Electric
TeSys Deca instantaneous auxiliary contact block, for LC
LAD8N20 Schneider Electric
LAD8N20
Schneider Electric
TeSys Deca instantaneous auxiliary contact block, for LC
LAD9ET1S Schneider Electric
LAD9ET1S
Schneider Electric
TeSys D safety protective cover, for preventing access to the moving contact carrier
LAD9R3 Schneider Electric
LAD9R3
Schneider Electric
TeSys D kit for reversing contactors assembly, for 3-pole contactors LC1D40A-D80A
LADN02 Schneider Electric
LADN02
Schneider Electric
TeSys D instantaneous auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADN04 Schneider Electric
LADN04
Schneider Electric
TeSys D instantaneous auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADN11 Schneider Electric
LADN11
Schneider Electric
TeSys D instantaneous auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADN13 Schneider Electric
LADN13
Schneider Electric
Schneider Electric's TeSys Deca auxiliary contact block offers 1NO+3NC instantaneous contacts rated up to 10A 690V AC. It is suitable for safety applications and can be easily mounted on front by clip-on.
LADN20 Schneider Electric
LADN20
Schneider Electric
TeSys D instantaneous auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADN22 Schneider Electric
LADN22
Schneider Electric
TeSys D instantaneous auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADN31 Schneider Electric
LADN31
Schneider Electric
TeSys D instantaneous auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADN40 Schneider Electric
LADN40
Schneider Electric
The TeSys Deca auxiliary contact block provides four normally open (NO) contacts for integration into control circuits with LC1D09 to LC1D150 contactors.
LADR0 Schneider Electric
LADR0
Schneider Electric
TeSys D time delay auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADR2 Schneider Electric
LADR2
Schneider Electric
TeSys D time delay auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADR4 Schneider Electric
LADR4
Schneider Electric
TeSys D time delay auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADS2 Schneider Electric
LADS2
Schneider Electric
TeSys D time delay auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADT0 Schneider Electric
LADT0
Schneider Electric
TeSys D time delay auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADT2 Schneider Electric
LADT2
Schneider Electric
TeSys D time delay auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADT4 Schneider Electric
LADT4
Schneider Electric
TeSys D time delay auxiliary contact block, for contactors LC1D, LC1F and control relays CAD

Części zapasowe

LXD3V7 Schneider Electric
LXD3V7
Schneider Electric
This is a contact coil of Tesys Deca contactors

Wgląd w rynek

AutomaINSIGHTS pulpit analityczny

Uzyskaj analizy w czasie rzeczywistym i dane rynkowe, aby zoptymalizować decyzje zakupowe dotyczące tego komponentu i podobnych produktów.

  • Dane o dostępności zapasów w czasie rzeczywistym od 700 dystrybutorów MRO w Europie i USA
  • Analiza cen według stanu (nowe, używane, odnowione) z medianą cen rynkowych
  • Monitorowanie dostępności krytycznych komponentów w celu zapobiegania przestojom produkcji
  • Wgląd w optymalizację zapasów w oparciu o trendy podaży rynkowej
Rozpocznij