1 / 1
thumbnail

Opis

Końcówka Serii
This XMLG electronic pressure sensor has a a pressure rating of 6 bar, a M12 connector electrical connection and a G 1/4 a DIN 3852-e male fluid connection. This pressure transmitter sensor is designed for accurate pressure control of fresh water (0°C-125°C), refrigeration fluids, hydraulic oils and corrosive fluids between -15°C and 125°C. It is fixed directly on tubage. It has a ceramic Al2O3 (Aluminium Oxide) cell and a stainless steel (AISI 303) body, this makes it compatible with corrosive non alkaline fluids. 10 million cycles mechanical durability for minimum required maintenance on your pressurized fluid circuits. It complies with EN/IEC 61326-2-3, CSA C22.2 No.14, UL 508, EAC. Well suited for a wide range of fluid types and applications from hydraulic and pneumatic installations to water pumps and machine tooling.
Country of Origin
CH
Part Number
XMLG006D21
Tariff Code
90262020
EAN
3389119018715
UNSPSC
39122210
Metody płatności:
Najlepsza oferta od:
GBZaufany dostawca Automa.Net
Dostępność:
1 szt.
W magazynie
Zaktualizowano: 21-10-2024
Szacowany czas dostawy:
Na zapytanie
Stan produktu:
Nowy, Rynek wtórny
Nowy, Rynek wtórny - Nowy, nieużywany, nieuszkodzony przedmiot bez gwarancji producenta. Przedmiot może być dostarczony bez oryginalnego opakowania lub w zastępczym opakowaniu. Jeśli dostarczono, pudełko mogło zostać otwarte.
Łącznie 3 części w magazynie od 3 dostawców
Dostawa z:
GB
GB
DE
DE
JO
JO
Bezpieczny proces płatności
Zasady zwrotu i refundacji
Zasady wysyłki
Gwarancja

Dostępne Oferty (2)

XMLG006D21 product image
Schneider Electric

XMLG006D21

Stan produktu:
Nowy, Rynek wtórny
Dostępność:
1 szt.
W magazynie
Zaktualizowano: 08-11-2024
Oferta od:
DEZaufany dostawca Automa.Net
Szacowany czas dostawy:
Na zapytanie
Gwarancja:
12 miesięcy
1
XMLG006D21 product image
Schneider Electric

XMLG006D21

Stan produktu:
Używany
Dostępność:
1 szt.
W magazynie
Zaktualizowano: 27-08-2024
Oferta od:
JOZaufany dostawca Automa.Net
Szacowany czas dostawy:
Na zapytanie
1
Oferta z czasem realizacji przez producenta
Wysyłka:Na zapytanie
Najlepsza cena:
Wyślij zapytanie o cenę

Specifications

Pressure Sensor Type
pressure transmitter
Electrical Connection
1 male connector M12, 3 pins
Type Of Output Signal
analogue
Diameter
22.8 mm
Range Of Product
Telemecanique Pressure sensors XM
Product Or Component Type
electronic pressure sensors
Type Of Packing
individual
Pressure Sensor Name
XMLG
Fluid Connection Type
G 1/4A (male) DIN 3852-E
Pressure Sensor Size
6 bar
Controlled Fluid
air -15-125 °C) || corrosive fluid -15-125 °C) || hydraulic oil -15-125 °C) || fresh water 0-125 °C)
Analogue Output Function
4...20 mA, 2 wires
Quantity Per Set
set of 1
[Us] Rated Supply Voltage
12 V DC 8-33 V) || 24 V DC 8-33 V)

Contractual warranty

Warranty
18 months

Complementary

Height
58.1 mm
Response Time On Output
< 2 ms
[Uimp] Rated Impulse Withstand Voltage
0.5 kV
Repeat Accuracy
+/- 0.1 % of the measuring range
Drift Of The Zero Point
+/- 0.015 % of measuring range/°C
Materials In Contact With Fluid
ceramic || FPM (Viton) || stainless steel type AISI 303
Length
48.5 mm
Local Display
without
Net Weight
0.095 kg
Current Consumption
< 20 mA
Surge Withstand
1 kV 42 Ohm EN/IEC 61000-4-5 || 500 kV 12 Ohm EN/IEC 61000-4-5
Scale Type
fixed differential
Mechanical Durability
10000000 cycles
Operating Position
any position
Measurement Accuracy
+/- 0.3 % of the measuring range
Protection Type
load short-circuit || reverse polarity
Electrical Circuit Type
control circuit
Drift Of The Sensitivity
+/- 0.015 % of measuring range/°C
Maximum Permissible Accidental Pressure
13.5 bar
Destruction Pressure
15 bar
Pressure Setting Range
0-6 bar

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
CSA C22.2 No 14 || EAC || UL 508
Resistance To Conducted Disturbances
30 V 0.15-80 Hz)EN/IEC 61000-4-6
Ambient Air Temperature For Operation
-15-85 °C
Resistance To Electromagnetic Fields
200 V/m 80-1000 Hz EN/IEC 61000-4-3
Standards
EN/IEC 61326-2-3 || CE
Shock Resistance
25 gn 11 ms EN/IEC 60068-2-27
Resistance To Magnetic Fields
30 A/m 50 Hz EN/IEC 61000-4-8
Vibration Resistance
20 gn 9-2000 Hz)EN/IEC 60028-2-6
Ip Degree Of Protection
IP66 conforming to EN/IEC 60529 || IP67 conforming to EN/IEC 60529
Nema Degree Of Protection
NEMA 4
Ambient Air Temperature For Storage
-40-85 °C
Resistance To Electrostatic Discharge
15 kV in air EN/IEC 61000-4-2 || 8 kV on contact EN/IEC 61000-4-2
Protective Treatment
TC
Resistance To Fast Transients
4 kV EN/IEC 61000-4-4