Lumberg

934849090

1 / 3
thumbnail
thumbnail
thumbnail

Description

M12 Power Single-Ended Cordset: Female, straight, 4-pin, L-coded, blue body, 50 V AC/60 V DC, 16 A; PUR black cable, 1.50 mm²
Part Number
934849090
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Approvals

UL-File
E497237
UL
UL 2237; cULus
VDE
Yes

Materials

Contact Base Material
CuNi
Contact Plating
Cu/Au
Contact Bearer Material
PBT GF
Contact Bearer Color
black
Flammability Class (Contact Bearer)
UL 94 V-2
Molded Body Material
TPE
Molded Body Color
blue
Flammability Class (Molded Body)
UL 94 HB
Attachment Material
CuZn
Attachment Plating
Cu/Ni
O-Ring Material
FKM

Resistances

Halogenfree
DIN VDE 0472 T.815
Oil Resistance
HD 22.10 Appendix A, DIN EN 60811-404

Additional Technical Data

Fastening Torque (Contact Screw)
M 12x1: (60-65) Ncm, hand-tight

Technical Data

Product Family
Power Connector
Product Sub Family
M12 Power
Brand
Lumberg Automation
Connector Type
Cordset, single ended
Type of Contact / Gender
female
Connector Design
straight
Number of Pins
4
Coding
L
Shielding
Unshielded
Attachment Type
Coupling Nut
Rated Voltage
63 V
Rated Voltage (UL)
63 V
Rated Impulse Voltage
1.5 kV
Rated Current*
16 A
Rated Current (UL)*
16 A
Contact Resistance
≤ 10 mOhm
Insulation Resistance
˃ 10^9 Ohm
Mating Cycles
≤ 100
Ambient Temperature (Operation)*
-40 °C to +125 °C, notice derating
Protection Degree / IP Rating**
IP65, IP67, IP69K
Design Standard
IEC 61076-2-111
Pollution Degree
3 acc. to DIN EN 60664-1 (VDE 0110-1)
Clearance / Creepage Distance
DIN EN 60664-1 (2008/01); VDE 0110-1
Overvoltage Category
III acc. to DIN EN 60664-1 (VDE 0110-1)

Specifications

Item Description
RKT 4L-723/2 M
Cable Length
2 m

Notes

Note Derating
Notice derating
Product Characteristics
To ensure ingress protection, please check the O-ring’s position before connecting. Improperly positioned O-ring leads to ingress protection potential failure.

Cable Data

Cable Number
723
Conductor Size
1.50 mm²
Number of Wires
4
Minimal Bending Radius (Fixed Inst)
˃ 4 x D
Minimal Bending Radius (Flexible Inst)
˃ 7.5 x D
Cycles (Bending)
˃ 10 M
Conductor material
Cu
Cable Jacket Material
PUR
Cable Jacket Color
black
Cable Diameter D
ø 7.4 ±0.20 mm
Wire Insulation Material
PP
Insulated Wire Diameter
ø 2.35 mm
Ambient Temperature (Fixed Installation)
-40 °C to +80 °C
Ambient Temperature (Flex Installation)
-30 °C to +80 °C
Ambient Temperature (Fixed Installation short-term 100h)
-40 °C to +125 °C
Ambient Temperature (Drag Chain Inst)
-20 °C to +60 °C
UL Cable Type
AWM: 20939
Flammability Class (Cable Jacket)
VDE 0482-332-1-2, DIN EN 60332-1-2 / IEC 60332-1 / UL VW-1, CSA FT1

Safety & Environmental Compliance

RoHS Compliant
Yes

Documents

Data Sheet

Download

Related products