1 / 1
thumbnail

Description

PLC-INTERFACE, consisting of DIN rail-mountable basic terminal block with screw connection and plug-in miniature relay with power contact, 1 PDT, input voltage: 120 V AC/110 V DC, UL/cUL: approved for use in Ex Zone Class I, Div. 2 and ATEX (Zone 2)
Country of Origin
DE
Part Number
2902956
Tariff Code
85364900
EAN
4046356957595
UPC
4046356957595
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Connection data input side

Connection name
Coil side
Connection method
Screw connection
Stripping length
8 mm
Screw thread
M3
Conductor cross section solid
0.14 mm² - 2.5 mm²
Conductor cross section flexible
0.14 mm² - 2.5 mm²
Conductor cross section flexible
0.2 mm² - 2.5 mm² ()
Conductor cross section flexible
2x 0.5 mm² - 1.5 mm² ()
Conductor cross section AWG
26 - 14

Connection data output side

Connection name
Contact side
Connection method
Screw connection
Stripping length
8 mm
Screw thread
M3
Conductor cross section solid
0.14 mm² - 2.5 mm²
Conductor cross section flexible
0.14 mm² - 2.5 mm²
Conductor cross section flexible
0.2 mm² - 2.5 mm² ()
Conductor cross section flexible
2x 0.5 mm² - 1.5 mm² ()
Conductor cross section AWG
26 - 14

Note

Utilization restriction
EMC: class A product, see manufacturer's declaration in the download area

Dimensions

Width
6.2 mm
Height
80 mm
Depth
94 mm

Contact side

Contact type
1 PDT
Type of switch contact
Single contact
Contact material
AgSnO
Maximum switching voltage
250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...)
Minimum switching voltage
5 V (at 100 mA)
Min. switching current
10 mA (at 12 V)
Maximum inrush current
10 A (4 s)
Limiting continuous current
6 A
Interrupting rating (ohmic load) max.
140 W (at 24 V DC)
Interrupting rating (ohmic load) max.
20 W (at 48 V DC)
Interrupting rating (ohmic load) max.
18 W (at 60 V DC)
Interrupting rating (ohmic load) max.
23 W (at 110 V DC)
Interrupting rating (ohmic load) max.
40 W (at 220 V DC)
Interrupting rating (ohmic load) max.
1500 VA (for 250 V AC)
Switching capacity
2 A (at 24 V, DC13)
Switching capacity
0.2 A (at 110 V, DC13)
Switching capacity
0.1 A (at 220 V, DC13)
Switching capacity
3 A (at 24 V, AC15)
Switching capacity
3 A (at 120 V, AC15)
Switching capacity
3 A (at 230 V, AC15)

Ambient conditions

Ambient temperature (operation)
-20 °C - 60 °C (UL)
Ambient temperature (operation)
-40 °C - 60 °C (ATEX / IECEx)
Ambient temperature (storage/transport)
-40 °C - 85 °C

Environmental Product Compliance

REACh SVHC
Lead 7439-92-1
China RoHS
Environmentally Friendly Use Period = 50
China RoHS
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Coil side

Nominal input voltage U<sub>N</sub>
120 V AC
Nominal input voltage U<sub>N</sub>
110 V DC
Typical input current at U<sub>N</sub>
3.5 mA (UN = 120 V AC)
Typical input current at U<sub>N</sub>
3 mA (UN = 110 V DC)
Typical response time
6 ms
Typical release time
15 ms
Protective circuit
Bridge rectifier Bridge rectifier
Operating voltage display
Yellow LED
Power dissipation for nominal condition
0.42 W

Standards and Regulations

Designation
Standards/regulations
Standards/regulations
IEC 60664
Standards/regulations
EN 50178
Standards/regulations
EN 60079-0, -7, -15
Degree of pollution
3
Overvoltage category
III
Flammability rating according to UL 94
V0
Conformance
CE-compliant
ATEX
 II 3G Ex ec nC IIC T4 Gc
IECEx
Ex ec nC IIC T4 Gc
UL, USA
Class I, Zone 2, AEx nA nC IIC T6
UL, USA/Canada
Class I, Div. 2, Groups A, B, C, D
UL, Canada
Class I, Zone 2, Ex nA nC IIC Gc T6 X