- [Us] Rated Supply Voltage
- 24 V DC non isolated +/- 20 %
- Current Consumption
- <= 40 mA voltage output || <= 60 mA current output
- Safety Reliability Data
- MTTFd = 43.9 years || B10d = 40564
- Measurement Error
- +/- 0.5 % of full scale 3 or 4 wires)20 °C || +/- 1 % of full scale 2 wires)20 °C || +/- 10 % of full scale20 °C electromagnetic interference of 10 V/m)
- Clamping Connection Capacity
- 2 x 1.5 mm² || 1 x 2.5 mm²
- [Ui] Rated Insulation Voltage
- 2000 V
- Marking
- CE
- Analogue Output Voltage
- -15...-11 V no input or input wire broken || 11...15 V no input or input wire broken
- Net Weight
- 0.12 kg
- Fixing Mode
- clip-on 35 mm symmetrical DIN rail) || fixed mounting plate)
- Surge Withstand
- 0.5 kV 1.2/50 µs IEC 61000-4-5
- Maximum Wiring Resistance
- 0.2 Ohm 2 wires
- Local Signalling
- for power ON LED (green)
- Temperature Coefficient
- 150 ppm/°C
- Protection Type
- short-circuit protection on output || reverse polarity protection on output || overvoltage protection on output (+/- 30 V) || reverse polarity protection on power supply
- Tightening Torque
- 0.6-1.1 N.m
- Analogue Output Current
- -30-0 mA no input or input wire broken || 22-30 mA no input or input wire broken
- Repeat Accuracy
- +/- 0.2 % full scale 20 °C || +/- 0.6 % full scale 60 °C