This XCMD miniature format limit switch has a steel roller plunger and a Zamak body. This limit switch has a robust Zamak miniature and modular body, is pre-cabled, allowing an easier installation. It is IP66 and IK06 impact resistant, making it ideal for heavy duty use in harsh conditions. It is fixed on the machine by its body, and has a typical 5 million cycles electrical durability in DC-13 utilization category. It complies with CCC, EN/IEC 60947.-5-1, CSA C22.2 No.14, EN/IEC 60204-1, UL 508 standards. Compatible with the well distributed range of common XCK heads, allowing quick replacement in case of damage. Variable composition design allows late modifications on the switch, for example change of connection type or head.- Country of Origin
- ID
- Part Number
- XCMD2102C12
- Tariff Code
- 85365080
- EAN
- 3389110221312
- UNSPSC
- 39122213
Payment methods:
- Best offer from:
- Trusted Automa.Net Supplier
- Availability:
- 20 pcs.In-StockUpdated at: 22-11-2024
- Estimated Delivery:
- On Request
- Condition:
- New Surplus
New Surplus - A new, unused, undamaged item without a manufacturer guarantee. The item may come without original packaging or in replacement packaging. If provided, the box may have been opened.
Shipping Information
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies
Specifications
- Movement Of Operating Head
- linear
- Range Of Product
- Telemecanique Limit switches XC Standard
- Fixing Mode
- by the body
- Type Of Operator
- spring return roller plunger metal
- Sensor Design
- miniature
- Product Or Component Type
- limit switch
- Head Material
- zamak
- Material
- metal
- Head Type
- plunger head
- Type Of Approach
- lateral approach, 2 directions
- Series Name
- standard format
- Contacts Type And Composition
- 1 NC + 1 NO
- Body Type
- plug-in body
- Contact Operation
- snap action
- Body Material
- zamak
- Device Short Name
- XCMD
- Number Of Poles
- 2
Contractual warranty
- Warranty
- 18 months
Complementary
- Height
- 50-50 mm
- Short-Circuit Protection
- 4 A cartridge fuse gG
- Electrical Connection
- male connector M12, 5 pins
- [Ithe] Conventional Enclosed Thermal Current
- 4 A
- Net Weight
- 0.09 kg
- [Uimp] Rated Impulse Withstand Voltage
- 0.8 kV IEC 60664 || 0.8 kV IEC 60947-1
- Switch Actuation
- by 30° cam
- [Ui] Rated Insulation Voltage
- 60 V 3)IEC 60947-5-1
- Electrical Durability
- 5000000 cycles, DC-13, 24 V, 3 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, 48 V, 2 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
- Positive Opening Minimum Force
- 35 N
- Positive Opening
- with
- Contacts Insulation Form
- Zb
- [Ie] Rated Operational Current
- 0.22 A 50 V, DC-13 EN/IEC 60947-5-1 appendix A || 3 A 50 V, AC-15 EN/IEC 60947-5-1 appendix A
- Mechanical Durability
- 10000000 cycles
- Maximum Actuation Speed
- 0.5 m/s
- Minimum Force For Tripping
- 7 N
- Width
- 30 mm
- Depth
- 16 mm
- Maximum Resistance Across Terminals
- 25 mOhm IEC 60255-7 category 3
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP110612EN
- Sustainable Offer Status
- Green Premium product
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Circularity Profile
- ENVEOLI110612EN
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
Environment
- Product Certifications
- CSA || UL || CCC
- Ik Degree Of Protection
- IK06 EN 62262
- Ambient Air Temperature For Operation
- -25-70 °C
- Standards
- CSA C22.2 No 14 || EN/IEC 60947-5-1 || EN/IEC 60204-1 || UL 508
- Shock Resistance
- 25 gn 18 ms IEC 60068-2-27
- Vibration Resistance
- 5 gn 10-500 Hz)IEC 60068-2-6
- Ip Degree Of Protection
- IP66 conforming to IEC 60529 || IP67 conforming to IEC 60529 || IP68 conforming to IEC 60529
- Ambient Air Temperature For Storage
- -40-70 °C
- Electrical Shock Protection Class
- class I IEC 61140 || class I NF C 20-030
- Protective Treatment
- TC