Tripp Lite
SU16KRT-1TF
1 / 6
- Part Number
- SU16KRT-1TF
- UPC
- 037332158253
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Overview
- UPC Code
- 037332158253
- UPS Type
- On-Line
Output
- Output Volt Amp Capacity (VA)
- 16000
- Output kVA Capacity (kVA)
- 16.00
- Output Watt Capacity (Watts)
- 14400
- Output kW Capacity (kW)
- 14.40
- Power Factor
- 0.9
- Crest Factor
- 3:1
- Nominal Voltage Details
- This configuration requires the Power Module be set to 208 or 240V output voltage; included step-down transformer supports 120V output (when the voltage-selection switch on the transformer module is set to match the 208 or 240V power module setting)
- Frequency Compatibility
- 60 Hz
- Frequency Compatibility Details
- Output frequency regulation +/- 0.05Hz (free running)
- Output Voltage Regulation (Line Mode)
- +/- 2%
- Output Voltage Regulation (Battery Mode)
- +/- 2%
- Output Receptacle Details
- Total 120V output is limited to 4992 watts for 208V input and 5760 watts for 240V input. Additional 120V capacity is available by adding a second SU6000XFMR2U step-down transformer.
- Output Circuit Breakers
- POWER MODULE: Two built-in 30A breakers protect one L6-30R outlet each, Eight built-in 20A breakers protect one C19 outlet each; TRANSFORMER MODULE: Two 15A breakers protect 2 5-15R outlets each, Two 20A breakers protect 4 5-15/20R outlets each
- Output AC Waveform (AC Mode)
- Pure Sine wave
- Output AC Waveform (Battery Mode)
- Pure Sine wave
- Output Capacity Details
- Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as load levels are reduced to 95% or less
- Nominal Output Voltage(s) Supported
- 120V; 208V; 240V
- Output Receptacles
- (4) 5-15R; (8) 5-15/20R; (2) L6-30R; (8) C19
- Individually Controllable Load Banks
- No
Input
- Rated input current (Maximum Load)
- 88.4A (208V), 76.6A (240V)
- Nominal Input Voltage(s) Supported
- 208V AC; 240V AC
- UPS Input Connection Type
- Hardwire
- UPS Input Connection Description
- 3 wire single phase input (L1, L2, G)
- Recommended Electrical Service
- 100A @ 208V, or 240V (L1, L2, G)
- Input Phase
- Single-Phase
Battery
- Full Load Runtime (min.)
- 5.5 minutes (14,400 watts)
- Half Load Runtime (min.)
- 13.5 minutes (7200 watts)
- Expandable Battery Runtime
- Runtime is expandable with external battery packs
- External Battery Pack Compatibility
- BP240V10RT3U; BP240V787C-1PH
- Expandable Runtime Description
- For best results, add external batteries in multiples of two so that both included 8kVA power modules have an equal number and type of connected battery packs
- DC System Voltage (VDC)
- 240
- Battery Recharge Rate (Included Batteries)
- Less than 6 hours from 10% to 90% (typical, full load discharge)
- Battery Replacement Description
- Hot-swappable, user replaceable external battery packs
- Expandable Runtime
- Yes
Voltage Regulation
- Voltage Regulation Description
- 2% output voltage regulation in standard online, double-conversion mode
- Overvoltage Correction
- Corrects overvoltages up to 300V
- Undervoltage Correction
- Corrects undervoltages as low as 100V
User Interface, Alerts & Controls
- Front Panel LCD Display
- Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats; LCD Display supports ENGLISH, FRENCH, GERMAN, ITALIAN, SPANISH and PORTUGUESE (see manual)
- Switches
- 2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions; bundled PDU includes bypass switch to enable hot-swap UPS power module replacement
- Alarm Cancel Operation
- Alarm cancel switch
- Audible Alarm
- Unique audible alarms for all major UPS, environmental and power conditions (see manual)
- LED Indicators
- 6 LEDs indicate line power, online mode, bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options
Surge / Noise Suppression
- UPS AC Suppression Joule Rating
- 2565
- UPS AC Suppression Response Time
- Instantaneous
- EMI / RFI AC Noise Suppression
- Yes
Physical
- Cooling Method
- Fans
- Included Battery Pack Dimensions (hwd / in.)
- 5.25 x 17.50 x 25.00
- Included Battery Pack Weight (lbs.)
- 158.7
- Included Mounting Accessory Description
- 5 sets of adjustable 4 post rack rails included (one for each included 2U/3U module)
- Installation Form Factors Supported with Included Accessories
- 4 post 19 inch rackmount
- Installation Form Factors Supported with Optional Accessories
- 2 post rackmount (2POSTRMKITHD); Tower (2-9USTAND)
- Maximum Device Depth (in.)
- 32.5
- Minimum Required Rack Depth (inches)
- 37.5
- Optional Mounting Accessory Notes
- Qty 5 2POSTRMKITHD required for 2 post rackmount installation; Qty 2 2-9USTAND required for tower installation
- Primary Form Factor
- Rackmount
- Primary UPS Depth (mm)
- 656
- Primary UPS Height (mm)
- 131
- Primary UPS Width (mm)
- 445
- Rack Height
- 14U
- Shipping Dimensions (hwd / in.)
- 31.50 x 40.00 x 51.00
- Shipping Weight (lbs.)
- 678.00
- Stepdown Transformer Depth (mm)
- 554
- Stepdown Transformer Dimensions (hwd / in.)
- 3.50 x 17.50 x 21.80
- Stepdown Transformer Height (mm)
- 89
- Stepdown Transformer Weight (lbs.)
- 72.6
- Stepdown Transformer Width (mm)
- 445
- UPS Dimensions Details
- Includes 2 SU8000RT3UPM UPS/Power modules, 2 BP240V10RT3U Battery packs, 1 SU6000XFMR2U transformer and SUPDMB20K parallel bypass PDU; Listed weights and dimensions for UPS/Power module, battery pack and transformer each refer to a single unit; MAXIMUM DEVICE DEPTH specification refers to the whole UPS installed depth with parallel bypass PDU installed
- UPS Housing Material
- Steel
- UPS Power Module Dimensions (hwd, in.)
- 5.14 x 17.50 x 25.82
- UPS Power Module Weight (kg)
- 19.50
- UPS Power Module Weight (lbs.)
- 43
Environmental
- Operating Temperature Range
- +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.
- Storage Temperature Range
- +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius.
- Relative Humidity
- 0 to 95%, non-condensing
- AC Mode BTU / Hr. (Full Load)
- 5464
- Battery Mode BTU / Hr. (Full Load)
- 4864
- AC Mode Efficiency Rating (100% Load)
- 90%
- Operating Elevation (ft.)
- 0-3000m (0 to 10,000 ft.)
- Audible Noise
- 60 dBA at front side 1 meter
- Operating Elevation (m)
- 0-3000 m
Communications
- Network Management Cards
- SNMPWEBCARD; TLNETCARD; WEBCARDLX; MODBUSCARD; RELAYIOCARD
- Network Monitoring Port Description
- Applications utilizing any supported network management card option, require the installation of two of the same model network card – install one card per included UPS power module; RELAYIOMINI installation requires removal of panel containing USB ports on each included UPS power module
- PowerAlert Software
- For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
- Communications Cable
- USB, DB9 serial and EPO cables included
- WatchDog Compatibility
- Supports Watchdog application, OS and hard-reboot restart options for remote applications
- Communications Interface
- USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface
Line / Battery Transfer
- Transfer Time
- No transfer time (0 ms.) in online, double-conversion mode
- Low Voltage Transfer to Battery Power (Setpoint)
- 100V
- High Voltage Transfer to Battery Power (Setpoint)
- 300V
Special Features
- Cold Start (Startup in Battery Mode During a Power Failure)
- Cold-start operation supported
- High Availability UPS Features
- Automatic inverter bypass; Battery Independent Restart; Hot swappable UPS power module; Hot swappable batteries; Manual bypass switch
- Green Energy-Saving Features
- Support for daily startup and shutoff
Certifications
- UPS Certifications
- Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category A (EMI); ROHS (Restriction of Hazardous Substances)
- UPS Certification Details
- IEC 61000-4-5 1995 B Surge Immunity
Warranty
- Product Warranty Period (Worldwide)
- 2-year limited warranty
- Connected Equipment Insurance (U.S., Canada & Puerto Rico)
- $250,000 Ultimate Lifetime Insurance
Documents
Data Sheet
DownloadOther Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther