Schneider Electric
9007CR67T10
1 / 1
Description
Active Mature
These industrial heavy duty limit switches are applied in almost any environments. The lever head switches have the largest diameter shaft in the industry. They also have a Viton Quadring shaft seal to ensure positive head and shaft sealing that is dust and watertight. This neutral position lever arm limit switch with standard pretravel has a body and receptacle which is good for hazardous locations. Limit switch has two normally open and two normally closed contact. The snap action contacts will change state when the lever arm in operated in the clockwise or counterclockwise direction. Contacts have an A600 and Q600 inductive ratings and 10A resistive rating. The proper lever arm for the application must be purchased separately. This limit switch is 6.10 inches tall, 2.72 inches wide and 2.79 inches deep. This limit switch is UL Listed for hazardous locations, Division I, Class I, Groups B, C, D and Class II, Groups E, F, G. Switch has a 0.50 inch conduit entry with 14 NPT. Limit switch is UL listed and CSA certified. The 9007C heavy duty metal limit switches, compact and standard, with 39mm plug-in bodies or 69mm fixed body for hazardous locations. The 9007 series limit switches are designed to withstand harsh industrial environments and are available in a wide range of options.- Country of Origin
- MX
- Part Number
- 9007CR67T10
- Tariff Code
- 8536509055
- EAN
- 39122213
- UPC
- 785901960843
- UNSPSC
- 39122213
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Specifications
- Movement Of Operating Head
- rotary
- Range Of Product
- 9007
- Electrical Connection
- screw-clamp terminals AWG 22...AWG 12), 1-2
- Fixing Mode
- by the body
- Cable Entry
- 1 entry for 1/2" - 14 NPT ANSI B1.20.1
- Product Or Component Type
- limit switch
- Material
- metal
- Type Of Operator
- zinc spring return without operating lever -)9007C lever
- Head Type
- rotary head
- Switch Actuation
- from left and right || CW and CCW
- Type Of Approach
- lateral approach, 2 directions
- Series Name
- heavy duty
- Contacts Type And Composition
- 2(NC-NO)
- Sale Per Indivisible Quantity
- 1
- Body Type
- fixed
- Level Or Class
- Class II Division 1 Groups E/F/G || Class I Division 1 Groups B/C/D
- Positive Opening
- without
- Contact Operation
- snap action
- Product Specific Application
- hazardous location box
- Device Short Name
- 9007CR
- Number Of Poles
- 2
Contractual warranty
- Warranty
- 18 months
Complementary
- Maximum Displacement Angle
- 90 °
- Height
- 6.1-6.1 in
- Terminals Description Iso N°1
- (5-6)NC || (7-8)NO || (1-2)NC || (3-4)NO
- Tripping Angle
- 10 °
- Contacts Material
- silver contacts
- [Ithe] Conventional Enclosed Thermal Current
- 10 A
- Contact Form
- Form Z
- Head Material
- zinc
- Net Weight
- 2.5 lb(US)
- Local Signalling
- without
- Function Available
- neutral position
- [Ui] Rated Insulation Voltage
- 600 V 3)UL 508 contact block || 600 V 3)CSA C22.2 No 14 contact block
- Short-Circuit Protection
- 10 A CC non-time delay
- [Ie] Rated Operational Current
- 1.2 A 600 V AC, A600 NEMA || 1.5 A 480 V AC, A600 NEMA || 3 A 240 V AC, A600 NEMA || 6 A 120 V AC, A600 NEMA || 0.11 A 250 V DC, R300 NEMA || 0.55 A 125 V DC, R300 NEMA
- Mechanical Durability
- 10000000 cycles
- Maximum Actuation Speed
- 90 ft/min with 45° cam angle, levers only || 130 ft/min with 30° cam angle, levers only
- Body Material
- aluminium
- Switch Function
- 2 SPDT-DB
- [Uimp] Rated Impulse Withstand Voltage
- 2.5 kV AC 1 min CE || 2.2 kV AC 1 min UL || 2.64 kV AC 1 s CSA
- Width
- 2.72 in
- Depth
- 2.79 in
- Minimum Torque For Tripping
- 4 lbf.in
- Electrical Durability
- 1000000 cycles
- Repeat Accuracy
- +/- 0.002 in linear travel of cam
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP111160EN
- Sustainable Offer Status
- Green Premium product
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
Environment
- Ambient Air Temperature For Operation
- -20-185 °F hazardous location
- Shock Resistance
- 60 gn 9 ms IEC 60068-2-27
- Vibration Resistance
- 25 gn 10-150 Hz)IEC 60068-2-6
- Ip Degree Of Protection
- IP67 conforming to IEC 60529
- Ambient Air Temperature For Storage
- -20-185 °F
- Environmental Characteristic
- standard environment
- Nema Degree Of Protection
- NEMA 1 Nema type 250 || NEMA 2 Nema type 250 || NEMA 4 Nema type 250 || NEMA 6 Nema type 250 || NEMA 6P Nema type 250 || NEMA 12 Nema type 250 || NEMA 13 Nema type 250
- Electrical Shock Protection Class
- class 0 IEC 61140
- Protective Treatment
- epoxy powder coat
Documents
Data Sheet
DownloadOther Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther