Schneider Electric

ATV12H018M2TQ

1 / 1
thumbnail

Description

Active Mature
Altivar Machine ATV12 is an offer of variable speed drives for commercial equipment and simple machines. It works at a rated power up to 0.18kW / 0.25hp and a rated voltage from 200V to 240V AC. It is designed with heatsink for normal environments and fan-cooled enclosure. It has advanced PID and catch on the fly functions, basic cabling, and easy motor control setting. Based on the needs, it can be delivered without heatsink, with embedded EMC filter, or as standard version. The Altivar 12 drive integrates as standard the Modbus communication protocol. This Altivar Machine ATV12 is designed for simple applications, in industry, commercial machines and HVAC machines such as conveyors, pumps, extractors, access barriers and treadmills. It conforms to IEC, UL and other international standards. SoMove software compatibility enables saving and transfering of configurations to spare drive, reducing maintenance downtime. It is sold in lot of 14. It features an optimized application of power and torque for ventilation and pumping applications, this allows up to 30% energy savings. The ATV12 range meets basic machine requirements united with simplicity.
Country of Origin
ID
Part Number
ATV12H018M2TQ
Tariff Code
85044095
EAN
3606480076565
UNSPSC
39122001
Payment methods:
Best offer from:
DETrusted Automa.Net Supplier
Availability:
1 pc.
In-Stock
Updated at: 08-11-2024
Warranty:
12 months
Estimated Delivery:
On Request
Condition:
New Surplus
New Surplus - A new, unused, undamaged item without a manufacturer guarantee. The item may come without original packaging or in replacement packaging. If provided, the box may have been opened.
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies

Specifications

Range Of Product
Altivar 12
Product Or Component Type
variable speed drive
Ip Degree Of Protection
IP20
Motor Power Kw
0.18 kW
[Us] Rated Supply Voltage
200...240 V - 15...10 %
Communication Port Protocol
Modbus
Mounting Mode
cabinet mount
Nominal Output Current
1.4 A
Product Specific Application
simple machine
Emc Filter
integrated
Maximum Horse Power Rating
0.25 hp
Supply Frequency
50/60 Hz +/- 5 %

Contractual warranty

Warranty
18 months

Complementary

Prospective Line Isc
1 kA
Network Frequency
50-60 Hz
Maximum Output Frequency
4 kHz
Height
143 mm
Power Dissipation In W
natural 18.0 W
Line Current
3.4 A 100 V heavy duty) || 2.8 A 120 V heavy duty)
Acceleration And Deceleration Ramps
S || U || linear from 0 to 999.9 s
Time Constant
20 ms +/- 1 ms for reference change
Maximum Output Voltage
240 V
Base Load Current At High Overload
1.4 A
Speed Drive Output Frequency
0.5-400 Hz
Transmission Frame
RTU
Asynchronous Motor Control Profile
quadratic voltage/frequency ratio || voltage/frequency ratio (V/f) || sensorless flux vector control
Relay Output Number
1
Transient Overtorque
150-170 % of nominal motor torque depending on drive rating and type of motor
Data Format
8 bits, configurable odd, even or no parity
Relative Symmetric Network Frequency Tolerance
5 %
Apparent Power
0.7 kVA 240 V heavy duty)
Net Weight
0.7 kg
Type Of Polarization
no impedance
Frequency Resolution
analog input converter A/D, 10 bits || display unit 0.1 Hz
Switching Frequency
2...16 kHz adjustable || 4...16 kHz with derating factor
Maximum Transient Current
2.1 A 60 s heavy duty) || 2.3 A 2 s heavy duty)
Communication Service
read holding registers (03) 29 words || write single register (06) 29 words || write multiple registers (16) 27 words || read/write multiple registers (23) 4/4 words || read device identification (43)
Connector Type
1 RJ45
Analogue Input Number
1
Motor Slip Compensation
adjustable || preset in factory
Discrete Output Number
2
Analogue Output Number
1
Physical Interface
2-wire RS 485
Method Of Access
server Modbus serial
Insulation
electrical between power and control
Tightening Torque
0.8 N.m
Number Of Addresses
1-247
Continuous Output Current
1.4 A 4 kHz
Speed Range
1-20
Discrete Input Number
4
Linearity Error
+/- 0.3 % of maximum value analogue input
Nominal Switching Frequency
4 kHz
Quantity Per Set
set of 14
Width
72 mm
Transmission Rate
9.6 kbit/s || 19.2 kbit/s || 38.4 kbit/s
Braking To Standstill
by DC injection
Depth
102.2 mm
Protection Type
line supply overvoltage || line supply undervoltage || overcurrent between output phases and earth || overheating protection || short-circuit between motor phases || against input phase loss in three-phase || thermal motor protection via the drive by continuous calculation of I²t
Sampling Duration
20 ms +/- 1 ms logic input || 10 ms analogue input

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP090201EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Circularity Profile
ENVEOLI100204EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
NOM || CSA || C-tick || UL || GOST || RCM || KC
Maximum Deflection Under Vibratory Load (During Operation)
1.5 mm at 2...13 Hz
Maximum Acceleration Under Shock Impact (During Operation)
150 m/s² at 11 ms
Standards
UL 508C || UL 618000-5-1 || EN/IEC 61800-5-1 || EN/IEC 61800-3
Pollution Degree
2
Electromagnetic Compatibility
electrical fast transient/burst immunity test level 4 EN/IEC 61000-4-4 || electrostatic discharge immunity test level 3 EN/IEC 61000-4-2 || immunity to conducted disturbances level 3 EN/IEC 61000-4-6 || radiated radio-frequency electromagnetic field immunity test level 3 EN/IEC 61000-4-3 || surge immunity test level 3 EN/IEC 61000-4-5 || voltage dips and interruptions immunity test EN/IEC 61000-4-11
Ambient Air Temperature For Operation
-10-40 °C without derating || 40-60 °C with current derating 2.2 % per °C
Vibration Resistance
1 gn 13-200 Hz)EN/IEC 60068-2-6 || 1.5 mm peak to peak 3-13 Hz) - drive unmounted on symmetrical DIN rail - EN/IEC 60068-2-6
Shock Resistance
15 gn 11 ms EN/IEC 60068-2-27
Marking
CE
Maximum Acceleration Under Vibrational Stress (During Operation)
10 m/s² at 13...200 Hz
Noise Level
0 dB
Regulation Loop
adjustable PID regulator
Ambient Air Temperature For Storage
-25-70 °C
Relative Humidity
5-95 % without condensation IEC 60068-2-3 || 5-95 % without dripping water IEC 60068-2-3
Assembly Style
on base plate
Operating Altitude
> 3280.84...6561.68 ft (> 1000...2000 m) with current derating 1 % per 100 m || <= 3280.84 ft (1000 m) without derating
Operating Position
vertical +/- 10 degree
Overvoltage Category
class III
Ambient Air Transport Temperature
-25-70 °C
Environmental Class (During Operation)
class 3C3 according to IEC 60721-3-3 || class 3S2 according to IEC 60721-3-3
Electromagnetic Emission
radiated emissions environment 1 category C2 EN/IEC 61800-3 2...16 kHz shielded motor cable || conducted emissions with integrated EMC filter environment 1 category C1 EN/IEC 61800-3 2, 4, 8, 12 and 16 kHz shielded motor cable <5 m || conducted emissions with integrated EMC filter environment 1 category C2 EN/IEC 61800-3 2...12 kHz shielded motor cable <5 m || conducted emissions with integrated EMC filter environment 1 category C2 EN/IEC 61800-3 2, 4 and 16 kHz shielded motor cable <10 m || conducted emissions with additional EMC filter environment 1 category C1 EN/IEC 61800-3 4...12 kHz shielded motor cable <20 m || conducted emissions with additional EMC filter environment 1 category C2 EN/IEC 61800-3 4...12 kHz shielded motor cable <50 m || conducted emissions with additional EMC filter environment 2 category C3 EN/IEC 61800-3 4...12 kHz shielded motor cable <50 m