Schneider Electric
DPER16
1 / 5
Description
Active Mature
Easy TeSys DPER thermal overload relay, 13A/690V, thermal setting range 9-13A, tripping class 10, for protection of 3-phase motors 5.5kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors DPE09-D38. Mounting on DIN rail or screw fixing, separated from the contactor. Multi standards certified (IEC, cUL), Green Premium compliant (RoHs/Reach).- Country of Origin
- FR
- Part Number
- DPER16
- Tariff Code
- 85364900
- EAN
- 3606485332468
- UNSPSC
- 39122330
Payment methods:
- Best offer from:
- Trusted Automa.Net Supplier
- Availability:
- 1 pc.In-StockUpdated at: 08-11-2024
- Warranty:
- 12 months
- Estimated Delivery:
- On Request
- Condition:
- New Surplus
New Surplus - A new, unused, undamaged item without a manufacturer guarantee. The item may come without original packaging or in replacement packaging. If provided, the box may have been opened.
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies
Environment
- Product Certifications
- cUL
- Standards
- EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || UL 60947-5-1 || cUL
- Ambient Air Temperature For Operation
- -20-60 °C without derating IEC 60947-4-1
- Shock Resistance
- 15 gn 11 ms IEC 60068-2-7
- Ip Degree Of Protection
- IP20 conforming to IEC 60529
- Vibration Resistance
- 6 gn on plate IEC 60068-2-6
- Ambient Air Temperature For Storage
- -60-70 °C
- Protective Treatment
- TH IEC 60068
- Temperature Compensation
- -20-60 °C
Specifications
- Thermal Protection Adjustment Range
- 9-13 A
- Relay Application
- overload protection
- Product Or Component Type
- thermal overload relay
- Product Name
- Easy TeSys DPER
- Thermal Overload Class
- class 10 IEC 60947-4-1
- Range
- Easy TeSys
- [Ui] Rated Insulation Voltage
- power circuit 600 V cUL || power circuit 690 V IEC 60947-4-1
- Product Compatibility
- contactor DPE09-38
- Device Short Name
- DPER
Complementary
- Network Frequency
- 0...400 Hz
- Height
- 66 mm
- [Ith] Conventional Free Air Thermal Current
- 5 A signalling circuit
- Auxiliary Contact Composition
- 1 NO + 1 NC
- Connections - Terminals
- control circuit screw clamp terminals 2 1-2.5 mm² flexible without cable end || control circuit screw clamp terminals 2 1-2.5 mm² flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm² solid without cable end || power circuit screw clamp terminals 1 1.5-6 mm² flexible without cable end || power circuit screw clamp terminals 1 1-4 mm² flexible with cable end || power circuit screw clamp terminals 1 1-6 mm² solid without cable end
- Phase Failure Sensitivity
- tripping current 130 % of Ir on two phase, the last one at 0
- [Ue] Rated Operational Voltage
- 690 V AC 0...400 Hz power circuit IEC 60947-4-1
- Network Type
- DC || AC
- Protection Type
- BS fuse 5 A - control circuit || GB2 circuit breaker 5 A - control circuit || gG fuse 5 A - control circuit
- Dielectric Strength
- 1.89 kV 50 Hz IEC 60947-1
- Net Weight
- 0.124 kg
- Permissible Current
- 1.5 A 240 V AC-15 signalling circuit || 0.1 A 250 V DC-13 signalling circuit
- Surge Withstand
- 6 kV IEC 60801-5
- Tripping Threshold
- 1.14 +/- 0.06 Ir IEC 60947-4-1
- Tightening Torque
- control circuit 1.7 N.m screw clamp terminals || power circuit 1.7 N.m screw clamp terminals
- Control Type
- Red push-button stop || Blue push-button reset
- Mounting Support
- separate, with specific accessories || under contactor
- [Uimp] Rated Impulse Withstand Voltage
- 6 kV
- Width
- 45 mm
- Depth
- 70 mm
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP080206EN
- Sustainable Offer Status
- Green Premium product
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- China Rohs Regulation
- Product out of China RoHS scope. Substance declaration for your information.
- Circularity Profile
- ENVEOLI0802006
- Eu Rohs Directive
- Compliant with Exemptions
CAD Models
traceparts
DownloadOther Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther