1
Payment methods:
Environment
- Mechanical Robustness
- vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor open6 Gn for 1/2 sine wave (11 ms) || shocks contactor closed15 Gn for 1/2 sine wave (11 ms)
- Ambient Air Temperature For Operation
- -5-40 °C
- Height
- 382 mm
- Net Weight
- 36 kg
- Ambient Air Temperature For Storage
- -60-80 °C
- Protective Treatment
- TH
- Ip Degree Of Protection
- IP20 front face with shrouds IEC 60529 || IP20 front face with shrouds VDE 0106
- Operating Altitude
- 9842.52 ft (3000 m) without derating
- Width
- 519 mm
- Depth
- 251 mm
- Permissible Ambient Air Temperature Around The Device
- -40-60 °C
Contractual warranty
- Warranty
- 18 months
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP110206EN
- Sustainable Offer Status
- Green Premium product
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation
- Product out of China RoHS scope. Substance declaration for your information.
- Circularity Profile
- ENVEOLI1102006EN
- Eu Rohs Directive
- Compliant with Exemptions
Complementary
- Product Certifications
- cETLus || CCC || CSA || CB || UKCA
- Power Dissipation Per Pole
- 250 W AC-1
- Average Impedance
- 0.1 mOhm - Ith 2600 A 50 Hz
- Control Circuit Voltage Limits
- operational: 0.85...1.1 Uc AC 40...400 Hz with LX1/LX9 coil || drop-out: 0.3...0.5 Uc AC 40...400 Hz with LX1/LX9 coil || operational: 0.85...1.1 Uc DC with LX4 coil || drop-out: 0.2...0.35 Uc DC with LX4 coil
- [Ith] Conventional Free Air Thermal Current
- 2600 A (at 60 °C)
- Standards
- IEC 60947-1 || IEC 60947-4-1 || EN 60947-4-1 || JIS C8201-4-1 || EN 60947-1
- [Uc] Control Circuit Voltage
- 110...500 V AC 40...400 Hz with LX1/LX9 coil || 110...440 V DC with LX4 coil
- Mounting Support
- plate
- Rated Breaking Capacity
- 3900 A conforming to IEC 60947-4-1
- Irms Rated Making Capacity
- 3900 A AC conforming to IEC 60947-4-1
- Associated Fuse Rating
- 2500 A gG at <= 440 V
- [Uimp] Rated Impulse Withstand Voltage
- 8 kV
- Inrush Power In Va
- 2200-2700 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil || 2130-2880 VA (at 20 °C)with LX4 coil
- Connections - Terminals
- power circuit bar 3 100 x 10 mm || control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible with cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm²solid without cable end || control circuit screw clamp terminals 1 1-4 mm² || control circuit screw clamp terminals 2 1-4 mm²
- Maximum Operating Rate
- 600 cyc/h 55 °C
- Operating Time
- 40...80 ms closing with LX1/LX9 coil || 100...200 ms opening with LX1/LX9 coil || 60...70 ms closing with LX4 coil || 40...50 ms opening with LX4 coil
- Tightening Torque
- power circuit 58 N.m || control circuit 1.2 N.m
- Mechanical Durability
- 0.5 Mcycles
- Compatibility Code
- LC1F
- Hold-In Power Consumption In Va
- 37.4-50.6 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil || 13-25 VA (at 20 °C)with LX4 coil
- Overvoltage Category
- III
- [Ui] Rated Insulation Voltage
- 1000 V IEC 60947-4-1
- [Icw] Rated Short-Time Withstand Current
- 12000 A 40 °C - 10 s || 9000 A 40 °C - 30 s || 7000 A 40 °C - 1 min || 6000 A 40 °C - 3 min || 4000 A 40 °C - 10 min
- Heat Dissipation
- 25-25 W
Specifications
- [Ue] Rated Operational Voltage
- <= 1000 V AC 50/60 Hz
- Contactor Application
- resistive load
- Product Or Component Type
- contactor
- Product Name
- TeSys F
- Range
- TeSys
- Pole Contact Composition
- 3 NO
- [Ie] Rated Operational Current
- 2600 A 60 °C) <= 440 V AC AC-1
- Utilisation Category
- AC-1
- Poles Description
- 3P
- Device Short Name
- LC1F
Documents
Data Sheet
DownloadCAD Models
traceparts
DownloadOther Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther