- Product Certifications
- LROS (Lloyds register of shipping) || ABS || RINA || BV || CSA || UL || RMRoS || DNV || CB || UKCA
- Power Dissipation Per Pole
- 37 W AC-1 || 21 W AC-3
- Average Impedance
- 0.3 mOhm - Ith 350 A 50 Hz
- [Ith] Conventional Free Air Thermal Current
- 350 A 40 °C
- Control Circuit Voltage Limits
- operational 0.85...1.1 Uc 55 °C) || drop-out 0.15...0.2 Uc 55 °C)
- Standards
- JIS C8201-4-1 || IEC 60947-1 || EN 60947-1 || IEC 60947-4-1 || EN 60947-4-1
- Mounting Support
- plate
- Control Circuit Type
- DC standard
- Contactor Coil Voltage
- 24 V DC standard
- Hold-In Power Consumption In W
- 5-5 W 20 °C
- Rated Breaking Capacity
- 2120 A IEC 60947-4-1
- Power Range
- 55-100 kW 200-240 V 3 phase || 110-220 kW 480-500 V 3 phase || 110-220 kW 380-440 V 3 phase
- Associated Fuse Rating
- 315 A aM <= 440 V || 400 A gG <= 440 V
- [Uimp] Rated Impulse Withstand Voltage
- 8 kV
- Connections - Terminals
- control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end || control circuit screw clamp terminals 1 1-4 mm²solid without cable end || control circuit screw clamp terminals 2 1-4 mm²solid without cable end || power circuit bar 2 32 x 4 mm || power circuit lugs-ring terminals 1 240-240 mm² || power circuit connector 1 240-240 mm² || power circuit bolted connection
- Pole Contact Composition
- 3 NO
- Motor Starter Type
- direct on-line contactor
- Operating Time
- 40...50 ms closing || 40...65 ms opening
- Maximum Operating Rate
- 2400 cyc/h 55 °C
- Mechanical Durability
- 10 Mcycles
- Tightening Torque
- control circuit 1.2 N.m || power circuit 35 N.m
- Inrush Power In W
- 750-750 W 20 °C)
- Compatibility Code
- LC1F
- Overvoltage Category
- III
- Motor Power Kw
- 132 kW 380...400 V AC 50/60 Hz AC-3) || 140 kW 415 V AC 50/60 Hz AC-3) || 140 kW 440 V AC 50/60 Hz AC-3) || 160 kW 500 V AC 50/60 Hz AC-3) || 160 kW 660...690 V AC 50/60 Hz AC-3) || 147 kW 1000 V AC 50/60 Hz AC-3) || 75 kW 220...230 V AC 50/60 Hz AC-3) || 51 kW 400 V AC 50/60 Hz AC-4)
- [Ui] Rated Insulation Voltage
- 1000 V IEC 60947-4-1 || 1500 V VDE 0110 group C
- [Icw] Rated Short-Time Withstand Current
- 2200 A 40 °C - 10 s || 1230 A 40 °C - 30 s || 950 A 40 °C - 1 min || 620 A 40 °C - 3 min || 480 A 40 °C - 10 min
- Heat Dissipation
- 5-5 W