Schneider Electric LC1K090087S7

Contactor, TeSys K, 4P, 2 NO + 2 NC, AC-1, lt or eq to 440V 10A, 500VAC coil

(2 offers)
Image of the product LC1K090087S7
A total of  1 Parts In-Stock from 1 Distributor
New: 1 pcs.
Contactor, TeSys K, 4P, 2 NO + 2 NC, AC-1, lt or eq to 440V 10A, 500VAC coil

Suppliers

In-Stock Parts

These parts are ready to be shipped immediately from warehouses across the world. Send inquiry for supplier details.
Register to See Company
Country: Germany
In Stock Updated 28/07/2024
  • Quantity: New: 1 pcs.

On Request Parts

These parts are not in the warehouse and will be quoted with manufacturer lead time. Send inquiry for supplier details.
Register to See Company
Country: Lithuania
On Request Updated 28/07/2024
  • Quantity: New: 0 pcs.

Additional information

Part Number LC1K090087S7
EAN 39121529
UNSPSC 39121529
Tariff Code 8536490065
RoHS Status Yes
Country of origin FR
Lifecycle status 00

Environment

Product Certifications CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
Standards EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1
Flame Retardance V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
Ambient Air Temperature For Storage -50-80 °C
Protective Treatment TC IEC 60068 || TC DIN 50016
Ip Degree Of Protection IP2X VDE 0106
Operating Altitude 6561.68 ft (2000 m) without derating

Contractual warranty

Warranty 18 months

Offer Sustainability

Rohs Exemption Information Yes
Mercury Free Yes
Environmental Disclosure ENVPEP1503003EN
Sustainable Offer Status Green Premium product
Toxic Heavy Metal Free Yes
Reach Regulation Free of Substances of Very High Concern above the threshold
California Proposition 65 WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
Reach Free Of Svhc Yes
Weee The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation Pro-active China RoHS declaration (out of China RoHS legal scope)
Circularity Profile ENVEOLI1503003EN
Eu Rohs Directive Compliant

Complementary

[Uc] Control Circuit Voltage 500 V AC 50/60 Hz
Mechanical Robustness shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27 || vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6 || vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6
[Ue] Rated Operational Voltage power circuit <= 690 V AC <= 400 Hz || signalling circuit <= 690 V AC <= 400 Hz
Height 58 mm
Average Impedance 3 mOhm - Ith 20 A 50 Hz for power circuit
Control Circuit Voltage Limits operational: 0.8...1.15 Uc (at <50 °C) || drop-out: >= 0.20 Uc (at <50 °C)
[Ith] Conventional Free Air Thermal Current 20 A (at 60 °C) for power circuit || 10 A (at 50 °C) for signalling circuit
Mounting Support plate || rail
Control Circuit Type AC 50/60 Hz
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Rated Breaking Capacity 110 A at 220...230 V conforming to IEC 60947 || 110 A at 380...400 V conforming to IEC 60947 || 110 A at 415 V conforming to IEC 60947 || 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conforming to IEC 60947
Irms Rated Making Capacity 110 A AC for power circuit conforming to IEC 60947
Associated Fuse Rating 25 A gG at <= 440 V for power circuit || 25 A aM for power circuit
Net Weight 0.18 kg
[Uimp] Rated Impulse Withstand Voltage 8 kV
Inrush Power In Va 30-30 VA (at 20 °C)
Connections - Terminals Faston terminals 2 2.8 mm) || Faston terminals 1 6.35 mm)
Pole Contact Composition 2 NO + 2 NC
Utilisation Category AC-1
[Ie] Rated Operational Current 20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit
Maximum Operating Rate 3600 cyc/h
Signalling Circuit Frequency <= 400 Hz
Electrical Durability 0.16 Mcycles 20 A AC-1 <= 690 V
Mechanical Durability 10 Mcycles
Poles Description 4P
Hold-In Power Consumption In Va 4.5-4.5 VA (at 20 °C)
Operating Time 10...20 ms coil de-energisation and NO opening || 10...20 ms coil energisation and NO closing || 15...25 ms coil de-energisation and NC closing || 5...15 ms coil energisation and NC opening
Width 45 mm
Overvoltage Category III
Depth 57 mm
[Ui] Rated Insulation Voltage power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA C22.2 No 14
[Icw] Rated Short-Time Withstand Current 90 A 50 °C - 1 s for power circuit || 85 A 50 °C - 5 s for power circuit || 80 A 50 °C - 10 s for power circuit || 60 A 50 °C - 30 s for power circuit || 45 A 50 °C - 1 min for power circuit || 40 A 50 °C - 3 min for power circuit || 20 A 50 °C - >= 15 min for power circuit
Heat Dissipation 1.3-1.3 W

Specifications

Contactor Application resistive load
Product Or Component Type contactor
Range TeSys
Device Application control
Device Short Name LC1K

Documents

Data Sheet

Download

CAD Models

TraceParts logo

TraceParts