Schneider Electric LR3D10L
Thermal overload relay, TeSys Deca, 690VAC, 4 to 6A, 1NO+1NC, class 20, for unbalanced loads
(6 offers)Never miss out on the parts you need!
Register now to receive instant notifications soon as they become available.
Register NowBenefits of creating an account.
- Register for instant notifications on part availability
- Get real-time alerts on inventory changes
- Notifications about hte total available quantity and conditions for each product.
A total of 2 Part In-Stock from 1 Distributor
New: 1 pcs.
Used: 1 pcs.
LR3D10L is a TeSys LRD thermal overload relay from Schneider Electric to be used with a TeSys D contactor. It protects motors 2.2kW@400V thanks to a thermal range 4-6A , a tripping class 20, for use with unbalanced loads. LR3D10L is a TeSys LRD thermal overload relay from Schneider Electric for direct mounting on TeSys D contactors. With a thermal setting range 4-6A and tripping class 20, it protects unbalanced loads and motors 2.2kW@400V. It provides manual test & reset buttons, automatic reset, trip auxiliary contact and flag indicator. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Thermal overload protection relay, bimetallic type, for use with unbalanced loads (non differential). Direct mounting on the bottom terminals of a Tesys contactor LC1D09-D38 to form a compact starter. Light and compact, 45mm wide. Temperature compensated for a good accuracy of the protection. Manual control with test & reset buttons, manual / automatic reset selector. Trip signaling with 1NO+1NC auxiliary contacts and trip flag indicator. Can be completed with terminal blocks for separate mounting (LAD7B, LAD96) and remote control devices (LAD703, LA7D03).
Suppliers
In-Stock Parts
These parts are ready to be shipped immediately from warehouses across the world. Send inquiry for supplier details.
Register to See Company
Country:
United States
In Stock
Updated 28/07/2024
- Quantity: New: 1 pcs. Used: 1 pcs.
On Request Parts
These parts are not in the warehouse and will be quoted with manufacturer lead time. Send inquiry for supplier details.
Additional information
Part Number | LR3D10L |
---|---|
EAN | 39122330 |
UNSPSC | 39122330 |
Tariff Code | 8536490075 |
RoHS Status | Yes |
Country of origin | TH |
Lifecycle status | 00 |
Environment
Product Certifications | IEC || UL || CSA || EAC || ABS || ATEX INERIS || UKCA |
---|---|
Mechanical Robustness | shocks15 Gn for 11 ms IEC 60068-2-7 || vibrations3 GN IEC 60068-2-6 |
Standards | EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || UL 60947-5-1 || CSA C22.2 No 60947-4-1 || CSA C22.2 No 60947-5-1 || EN 50495 |
Climatic Withstand | IACS E10 |
Ambient Air Temperature For Operation | -20-60 °C without derating IEC 60947-4-1 |
Dielectric Strength | 1.89 kV 50 Hz IEC 60947-1 |
Ip Degree Of Protection | IP20 conforming to IEC 60529 |
Ambient Air Temperature For Storage | -60-70 °C |
Contractual warranty
Warranty | 18 months |
---|
Offer Sustainability
Rohs Exemption Information | Yes |
---|---|
Mercury Free | Yes |
Environmental Disclosure | ENVPEP080206EN |
Sustainable Offer Status | Green Premium product |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov |
Weee | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
China Rohs Regulation | Product out of China RoHS scope. Substance declaration for your information. |
Circularity Profile | ENVEOLI0802006 |
Eu Rohs Directive | Compliant with Exemptions |
Complementary
Network Frequency | 0...400 Hz |
---|---|
Height | 66 mm |
[Ith] Conventional Free Air Thermal Current | 5 A signalling circuit |
Auxiliary Contact Composition | 1 NO + 1 NC |
Connections - Terminals | control circuit screw clamp terminals 2 1-2.5 mm² flexible without cable end || control circuit screw clamp terminals 2 1-2.5 mm² flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm² solid without cable end || power circuit screw clamp terminals 1 1.5-10 mm² flexible without cable end || power circuit screw clamp terminals 1 1-4 mm² flexible with cable end || power circuit screw clamp terminals 1 1-6 mm² solid without cable end |
Phase Failure Sensitivity | tripping current 130 % of Ir on two phase, the last one at 0 |
[Ue] Rated Operational Voltage | 690 V AC 0...400 Hz power circuit IEC 60947-4-1 |
Associated Fuse Rating | 4 A gG for signalling circuit || 4 A BS for signalling circuit |
Net Weight | 0.144 kg |
[Uimp] Rated Impulse Withstand Voltage | 6 kV |
Permissible Current | 3 A 120 V AC-15 signalling circuit || 0.22 A 125 V DC-13 signalling circuit |
Tripping Threshold | 1.14 +/- 0.06 Ir IEC 60947-4-1 |
Tightening Torque | control circuit 1.7 N.m screw clamp terminals || power circuit 1.7 N.m screw clamp terminals |
Control Type | Red push-button stop || Blue push-button reset |
Mounting Support | plate, with specific accessories || rail, with specific accessories || under contactor |
Width | 45 mm |
Depth | 76 mm |
Temperature Compensation | -20-60 °C |
Specifications
Network Type | AC || DC |
---|---|
Thermal Protection Adjustment Range | 4-6 A |
Relay Application | motor protection |
Product Or Component Type | non differential thermal overload relay |
Product Name | TeSys LRD || TeSys Deca |
Thermal Overload Class | class 20 IEC 60947-4-1 |
Range | TeSys |
[Ui] Rated Insulation Voltage | power circuit 600 V CSA || power circuit 600 V UL || power circuit 690 V IEC 60947-4-1 |
Product Compatibility | LC1D32 || LC1D18 || LC1D12 || LC1D09 || LC1D25 || LC1D38 |
Device Short Name | LR3D |