Schneider Electric
METSEEM4236B401
1 / 1
Description
Active Mature
The PowerLogic EM4200 Series Enercept power and energy meter is a unique compact retrofit solution for measuring energy data. This bundle ships with 3, 400 A split-core current transformers. Accuracy calibrated at 1%. ANSI version, fuse packs factory mounted. Designed for simplicity, the EM4200 has flexibility of a wide range of Current Transducers to match most applications from 50-5000A. This billing-rated, four-quadrant meter offers BACnet and Modbus communication protocols and supply power options from 90-480VAC. ANSI C12.1 rated and UL 61010-1.- Country of Origin
- US
- Part Number
- METSEEM4236B401
- EAN
- 83101808
- UNSPSC
- 83101808
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Reach Regulation
- Free of Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Reach Free Of Svhc
- Yes
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation
- Product out of China RoHS scope. Substance declaration for your information.
- Eu Rohs Directive
- Compliant with Exemptions
Complementary
- Network Frequency
- 50 Hz || 60 Hz
- Provided Equipment
- bracket for support || hook || split core current transducer 3 || fuse
- Height
- 152.36 mm
- Measurement Voltage
- 90-90 V AC 45...65 Hz minimum per phase || 480-480 V AC 45...65 Hz between phases || 300-300 V AC 45...65 Hz between phase and neutral
- Number Of Outputs
- 0
- Standards
- EN 61010-1 || UL 61010-1 || CAN/CSA C22.2 No. 61010-1-12
- Product Certifications
- CE EN 61010-1 || cULus UL 61010-1 || BTL || ANSI
- Communication Port Protocol
- Modbus RTU 9600 bauds...115200 bauds (automatic detection) || BACnet MS/TP 9600 bauds...115200 bauds (automatic detection)
- Frequency Measurement Range
- 45-65 Hz
- Communication Of Data
- remote control orders || total energy || net energy
- Number Of Inputs
- 0
- Depth
- 35.81 mm
- Measurement Current
- 0-400 A
- Wire Stripping Length
- 6 mm
- Local Signalling
- status LED green and red) || line fault 3 LED green, orange and red) || dial pointer indication LED Yellow) || RX/TX 2 LED green, orange and red)
- Connections - Terminals
- input/output plug-in connector bottom) 0.2-1.5 mm² || current transformer plug-in connector bottom) 0.2-1.5 mm² || communication plug-in connector bottom) 0.2-1.5 mm²
- Function Available
- external synchronisation to communication || fixed or rolling block
- Mounting Mode
- by screws || clip-on || by hook
- Measurement Accuracy
- 1 %
- Mounting Support
- enclosure || DIN rail
- Line Rated Current
- 400 A
- Analogue Input Type
- split core current transducer 0.333 V (impedance 33 kOhm) || voltage (impedance 2.5 MOhm)single phase || voltage (impedance 5 MOhm)phase to phase
- Width
- 46.63 mm
- Display Type
- Without Display
- Accuracy Class
- class 1 ANSI C12.1 || class 1S IEC 62053-22
- Metering Type
- active, reactive, apparent energy (signed, four quadrant) || apparent power S, S1, S2, S3 || demand power P, Q, S || active power P, P1, P2, P3 || reactive power Q, Q1, Q2, Q3 || power factor || average current Iavg || peak demand power PM, QM, SM || frequency || voltage U21, U32, U13, V1, V2, V3
Environment
- Ambient Air Temperature For Operation
- -30-70 °C
- Electromagnetic Compatibility
- conducted and radiated emissions conforming to FCC Part 15 class A || conducted and radiated emissions conforming to EN 61000-6-4 || conducted and radiated emissions conforming to EN 61326 + A1 || immunity to conducted disturbances conforming to EN 61000-6-2 || immunity to conducted disturbances conforming to EN 61326-1 || immunity to radiated fields conforming to EN 61000-6-2 || immunity to radiated fields conforming to EN 61326-1
- Pollution Degree
- 2
- Ambient Air Temperature For Storage
- -40-85 °C
- Relative Humidity
- 0-95 %
- Ip Degree Of Protection
- IP20 IEC 60529
- Measurement Category
- category III 277-277 V || category III 300-300 V
- Operating Altitude
- < 9842.52 ft (3000 m)
Specifications
- Product Or Component Type
- energy meter
- Product Name
- PowerLogic EM4200
- Type Of Cable
- ANSI cable
- Range
- PowerLogic
- Device Application
- power monitoring
- Device Short Name
- Enercept
Documents
Data Sheet
DownloadOther Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther