Active Mature
The PowerLogic EM4200 Series Enercept power and energy meter is a unique compact retrofit solution for measuring energy data. This bundle ships with 3, 400 A split-core current transformers. Accuracy calibrated at 1%. ANSI version, fuse packs factory mounted. Designed for simplicity, the EM4200 has flexibility of a wide range of Current Transducers to match most applications from 50-5000A. This billing-rated, four-quadrant meter offers BACnet and Modbus communication protocols and supply power options from 90-480VAC. ANSI C12.1 rated and UL 61010-1.
Country of Origin
US
Part Number
METSEEM4236B401
EAN
83101808
UNSPSC
83101808
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Reach Regulation
Free of Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Reach Free Of Svhc
Yes
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
Product out of China RoHS scope. Substance declaration for your information.
Eu Rohs Directive
Compliant with Exemptions

Complementary

Network Frequency
50 Hz || 60 Hz
Provided Equipment
bracket for support || hook || split core current transducer 3 || fuse
Height
152.36 mm
Measurement Voltage
90-90 V AC 45...65 Hz minimum per phase || 480-480 V AC 45...65 Hz between phases || 300-300 V AC 45...65 Hz between phase and neutral
Number Of Outputs
0
Standards
EN 61010-1 || UL 61010-1 || CAN/CSA C22.2 No. 61010-1-12
Product Certifications
CE EN 61010-1 || cULus UL 61010-1 || BTL || ANSI
Communication Port Protocol
Modbus RTU 9600 bauds...115200 bauds (automatic detection) || BACnet MS/TP 9600 bauds...115200 bauds (automatic detection)
Frequency Measurement Range
45-65 Hz
Communication Of Data
remote control orders || total energy || net energy
Number Of Inputs
0
Depth
35.81 mm
Measurement Current
0-400 A
Wire Stripping Length
6 mm
Local Signalling
status LED green and red) || line fault 3 LED green, orange and red) || dial pointer indication LED Yellow) || RX/TX 2 LED green, orange and red)
Connections - Terminals
input/output plug-in connector bottom) 0.2-1.5 mm² || current transformer plug-in connector bottom) 0.2-1.5 mm² || communication plug-in connector bottom) 0.2-1.5 mm²
Function Available
external synchronisation to communication || fixed or rolling block
Mounting Mode
by screws || clip-on || by hook
Measurement Accuracy
1 %
Mounting Support
enclosure || DIN rail
Line Rated Current
400 A
Analogue Input Type
split core current transducer 0.333 V (impedance 33 kOhm) || voltage (impedance 2.5 MOhm)single phase || voltage (impedance 5 MOhm)phase to phase
Width
46.63 mm
Display Type
Without Display
Accuracy Class
class 1 ANSI C12.1 || class 1S IEC 62053-22
Metering Type
active, reactive, apparent energy (signed, four quadrant) || apparent power S, S1, S2, S3 || demand power P, Q, S || active power P, P1, P2, P3 || reactive power Q, Q1, Q2, Q3 || power factor || average current Iavg || peak demand power PM, QM, SM || frequency || voltage U21, U32, U13, V1, V2, V3

Environment

Ambient Air Temperature For Operation
-30-70 °C
Electromagnetic Compatibility
conducted and radiated emissions conforming to FCC Part 15 class A || conducted and radiated emissions conforming to EN 61000-6-4 || conducted and radiated emissions conforming to EN 61326 + A1 || immunity to conducted disturbances conforming to EN 61000-6-2 || immunity to conducted disturbances conforming to EN 61326-1 || immunity to radiated fields conforming to EN 61000-6-2 || immunity to radiated fields conforming to EN 61326-1
Pollution Degree
2
Ambient Air Temperature For Storage
-40-85 °C
Relative Humidity
0-95 %
Ip Degree Of Protection
IP20 IEC 60529
Measurement Category
category III 277-277 V || category III 300-300 V
Operating Altitude
< 9842.52 ft (3000 m)

Specifications

Product Or Component Type
energy meter
Product Name
PowerLogic EM4200
Type Of Cable
ANSI cable
Range
PowerLogic
Device Application
power monitoring
Device Short Name
Enercept

Documents

Data Sheet

Download