Schneider Electric RE17LCBMS
Modular timing relay, Harmony, 0.7A, 1s..100h, off delay, solid state output, spring terminals, 24...240V AC
Never miss out on the parts you need!
Register now to receive instant notifications soon as they become available.
Register NowBenefits of creating an account.
- Register for instant notifications on part availability
- Get real-time alerts on inventory changes
- Notifications about hte total available quantity and conditions for each product.
This modular timing relay belongs to the Schneider Electric Harmony Timer relays range. This is an off-delay timer with single function and is activated by the control input Y1 when connected to 0V. This is a 17.5mm slim relay with input of 24Vac to 240Vac and solid state output of 0.7A. It has one of slimmest form-factors, allowing for a flexible and easy installation on DIN rail using the same space as any modular 1-pole DIN device. This is a spring terminal type relay with a sealable cover and rotary trimmers for simple and precise settings. It has 7 selectable timing ranges of 1s, 10s, 1min, 10min, 1h, 10h, and 100h and 2 dials for adjusting. It weighs 0.050Kg. 0 0 The product conforms to IEC 61812-1 and EN 61812-1 standards, and UL, CSA, GL, RCM, EAC, CCC, and China ROHS certifications. 0 0 0 The spring terminals timing relays bring you easy, time-saving and secured wiring during installation and maintenance. 0 0 0 0 0
Additional information
Part Number | RE17LCBMS |
---|---|
EAN | 3606489861537 |
UNSPSC | 39122329 |
Tariff Code | 85364900 |
RoHS Status | Yes |
Country of origin | ID |
Lifecycle status | 00 |
Specifications
Discrete Output Type | solid state |
---|---|
Range Of Product | Harmony Timer Relays |
Product Or Component Type | single function relay |
Component Name | RE17L |
Time Delay Range | 10...100 h || 6...60 s || 6...60 min || 1...10 h || 1...10 s || 1...10 min || 0.1...1 s |
Nominal Output Current | 0.7 A |
Width | 17.5 mm |
Time Delay Type | off-delay |
Complementary
Safety Reliability Data | MTTFd = 353.8 years || B10d = 320000 |
---|---|
Setting Accuracy Of Time Delay | +/- 10 % of full scale 25 °C IEC 61812-1 |
Height | 90 mm |
Creepage Distance | 4 kV/3 IEC 60664-1 |
Maximum Delay Response | 100 ms |
Control Type | selector switch front panel |
Insulation Resistance | 100 MOhm 500 V DC IEC 60664-1 |
Power Consumption In Va | 0-3 VA 240 V AC |
Dielectric Strength | 2.5 kV 1 mA/1 minute 50 Hz IEC 61812-1 |
Marking | CE |
Voltage Range | 0.85...1.1 Us |
Reset Time | 350 ms on de-energisation typical |
Operating Rate In Hz | 10 Hz |
Net Weight | 0.05 kg |
Maximum Voltage Drop | <4 V 3-wire || <8 V 2-wire |
Mounting Position | any position in relation to normal vertical mounting plane |
Voltage Drift | +/- 0.2 %/V |
Maximum Switching Voltage | 250 V AC |
Connections - Terminals | spring terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) solid without cable end || spring terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible without cable end |
Functionality | off-delay timing |
[Us] Rated Supply Voltage | 24...240 V AC 50/60 Hz |
Temperature Drift | +/- 0.05 %/°C |
Input Voltage | 7 V |
Minimum Switching Current | 10 mA |
Mounting Support | 35 mm DIN rail conforming to EN/IEC 60715 |
Maximum Output Current | 20 A |
Compatibility Code | RE17 |
On-Load Factor | 100 % |
Housing Material | self-extinguishing |
Impulse Duration | 0.05 s typical |
Maximum Leakage Current | 5 mA |
Time Delay Type | C |
[Uimp] Rated Impulse Withstand Voltage | 5 kV 1.2/50 µs |
Depth | 72 mm |
Electrical Durability | 100000000 cycles |
Breaking Capacity | 0.5 A AC UL || 0.7 A AC 20 °C |
Supply Frequency | 50...60 Hz +/- 5 % |
Repeat Accuracy | +/- 0.5 % IEC 61812-1 |
Offer Sustainability
Rohs Exemption Information | Yes |
---|---|
Mercury Free | Yes |
Environmental Disclosure | ENVPEP121117EN |
Sustainable Offer Status | Green Premium product |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Weee | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
China Rohs Regulation | X |
Circularity Profile | ENVEOLI121113EN |
Eu Rohs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Environment
Product Certifications | CSA || cULus || DNV-GL || EAC |
---|---|
Ambient Air Temperature For Operation | -20-60 °C |
Standards | 2004/108/EC || EN 61000-6-3 || 2006/95/EC || EN 61000-6-2 || IEC 61812-1 || EN 61000-6-4 || EN 61000-6-1 |
Immunity To Microbreaks | 20 ms |
Electromagnetic Compatibility | electrostatic discharge immunity test 6 kV in contact) level 3 IEC 61000-4-2 || electrostatic discharge immunity test 8 kV in air) level 3 IEC 61000-4-2 || susceptibility to electromagnetic fields 10 V/m 80 MHz to 1 GHz) level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test 1 kV capacitive connecting clip) level 3 IEC 61000-4-4 || electrical fast transient/burst immunity test 2 kV direct) level 3 IEC 61000-4-4 || 1.2/50 µs shock waves immunity test 1 kV differential mode) level 3 IEC 61000-4-5 || 1.2/50 µs shock waves immunity test 2 kV common mode) level 3 IEC 61000-4-5 || conducted RF disturbances 10 V 0.15...80 MHz) level 3 IEC 61000-4-6 || voltage dips and interruptions immunity test 0 % 1 cycle) IEC 61000-4-11 || voltage dips and interruptions immunity test 70 % 25/30 cycles) IEC 61000-4-11 || conducted and radiated emissionsclass B EN 55022 |
Shock Resistance | 15 gn 11 ms IEC 60068-2-27 |
Vibration Resistance | 20 m/s² 10-150 Hz)IEC 60068-2-6 |
Ip Degree Of Protection | IP20 IEC 60529 terminal block) || IP40 IEC 60529 housing) || IP50 IEC 60529 front panel) |
Ambient Air Temperature For Storage | -30-60 °C |
Relative Humidity | 93-93 % without condensation IEC 60068-2-30 |
Derating Factor | 5 mA/°C |