Schneider Electric
RE22R2QTMR
1 / 6
Description
Active Mature
This Harmony RE22 modular single function timer can be set between 1 seconds and 300 hours. It provides function Qt and it is mountable on DIN rail. This modular single function timing relay is ideal for providing timing control in automation systems such as automatic door opening, alarm, lighting in toilets and car park barriers. It has one of market slimmest form-factors with 22.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 2-pole DIN device. It also offers a sealable cover, simple and precise settings with rotary trimmers. Selectable timing range offers a one stop solution for your power management system. Single function timer for a simple integration in hard-wired logic schematics, ideal for refurbishment of old installations without using a PLC. 0 0 0 0 0 0 0 0 0 0 0 0- Country of Origin
- ID
- Part Number
- RE22R2QTMR
- Tariff Code
- 85364900
- EAN
- 3606480792540
- UNSPSC
- 39122329
Payment methods:
- Best offer from:
- Trusted Automa.Net Supplier
- Availability:
- 3 pcs.In-StockUpdated at: 09-11-2024
- Warranty:
- 12 months
- Estimated Delivery:
- On Request
- Condition:
- New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies
Specifications
- Discrete Output Type
- relay
- Range Of Product
- Harmony Timer Relays
- Product Or Component Type
- single function relay
- Nominal Output Current
- 8 A
- Device Short Name
- RE22
Environment
- Product Certifications
- CCC || GL || UL || EAC || RCM || CSA || CE
- Ambient Air Temperature For Operation
- -20-60 °C
- Standards
- IEC 61812-1 || UL 508
- Electromagnetic Compatibility
- fast transients immunity test - test level: 1 kV level 3 (capacitive connecting clip) conforming to IEC 61000-4-4 || surge immunity test - test level: 1 kV level 3 (differential mode) conforming to IEC 61000-4-5 || surge immunity test - test level: 2 kV level 3 (common mode) conforming to IEC 61000-4-5 || electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2 || electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 (80 MHz...1 GHz) conforming to IEC 61000-4-3 || conducted RF disturbances - test level: 10 V level 3 (0.15...80 MHz) conforming to IEC 61000-4-6 || fast transient bursts - test level: 2 kV level 3 (direct contact) conforming to IEC 61000-4-4 || immunity to microbreaks and voltage drops - test level: 30 % (500 ms) conforming to IEC 61000-4-11 || immunity to microbreaks and voltage drops - test level: 100 % (20 ms) conforming to IEC 61000-4-11
- Dielectric Strength
- 2.5 kV 1 mA/1 minute 50 Hz between relay output and power supply basic insulation IEC 61812-1
- Shock Resistance
- 15 gn not operating 11 ms IEC 60068-2-27 || 5 gn in operation 11 ms IEC 60068-2-27
- Vibration Resistance
- 20 m/s² 10-150 Hz)IEC 60068-2-6
- Pollution Degree
- 3 IEC 60664-1
- Directives
- 2006/95/EC - low voltage directive || 2004/108/EC - electromagnetic compatibility
- Ambient Air Temperature For Storage
- -40-70 °C
- Relative Humidity
- 95-95 % 25-55 °C
- Ip Degree Of Protection
- housing IP40 IEC 60529 || terminals IP20 IEC 60529 || front panel IP50 IEC 60529
Complementary
- Power Consumption In W
- 1.5 W 240 V DC
- Safety Reliability Data
- MTTFd = 342.4 years || B10d = 320000
- Contacts Type And Composition
- 2 C/O timed contact, cadmium free
- Setting Accuracy Of Time Delay
- +/- 10 % of full scale 25 °C IEC 61812-1
- Creepage Distance
- 4 kV/3 IEC 60664-1
- Maximum Delay Response
- 100 ms
- Control Type
- rotary knob || diagnostic button
- Insulation Resistance
- 100 MOhm 500 V DC IEC 60664-1
- Immunity To Microbreaks
- 10 ms
- Power Consumption In Va
- 3-3 VA 240 V AC
- Switching Capacity In Va
- 2000 VA
- Maximum Switching Current
- 8 A
- Voltage Range
- 0.85...1.1 Us
- Net Weight
- 0.105 kg
- Mounting Position
- any position
- Voltage Drift
- +/- 0.2 %/V
- Reset Time
- 120 ms on de-energisation
- Maximum Switching Voltage
- 250 V AC
- Connections - Terminals
- screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end || screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end || screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end || screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end
- [Us] Rated Supply Voltage
- 24...240 V AC/DC 50/60 Hz
- Temperature Drift
- +/- 0.05 %/°C
- Time Delay Range
- 1...10 s || 3...30 s || 10...100 s || 30...300 min || 0.05...1 s || 3...30 min || 0.3...3 s || 30...300 s || 3...30 h || 30...300 h
- Minimum Switching Current
- 10 mA 5 V DC
- Overvoltage Category
- III IEC 60664-1
- Input Voltage
- <= 2.4 V
- Mounting Support
- 35 mm DIN rail conforming to IEC 60715
- Electrical Durability
- 100000 cycles, 8 A at 250 V, AC-1 || 100000 cycles, 2 A at 24 V, DC-1
- Mechanical Durability
- 10000000 cycles
- Housing Material
- self-extinguishing
- Status Led
- Green LED backlight steady)dial pointer indication || Yellow LED steady)output relay energised || Yellow LED fast flashing)timing in progress and output relay de-energised || Yellow LED slow flashing)timing in progress and output relay energised
- [Uimp] Rated Impulse Withstand Voltage
- 5 kV 1.2-50 µs IEC 60664-1
- Width
- 22.5 mm
- Time Delay Type
- star-delta
- Tightening Torque
- 0.6-1 N.m IEC 60947-1
- Supply Frequency
- 50...60 Hz +/- 5 %
- Repeat Accuracy
- +/- 0.5 % IEC 61812-1
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP1401008EN
- Sustainable Offer Status
- Green Premium product
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- China Rohs Regulation
- X
- Circularity Profile
- ENVEOLI1401008EN
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
CAD Models
traceparts
DownloadOther Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther