1 / 1
thumbnail

Description

Active Mature
Country of Origin
FR
Part Number
XC2JC161
Tariff Code
85365080
EAN
3389110325706
UNSPSC
39122213
Payment methods:
Best offer from:
EETrusted Automa.Net Supplier
Availability:
6 pcs.
In-Stock
Updated at: 22-05-2024
Warranty:
12 months
Estimated Delivery:
On Request
Condition:
New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
A total of 7 Parts In-Stock from 2 Distributors
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies

Available Offers (1)

XC2JC161 product image
Schneider Electric

XC2JC161

Condition:
New Surplus
Available:
1 pc.
In-Stock
Updated at: 08-11-2024
Offer from:
DETrusted Automa.Net Supplier
Estimated Delivery:
On Request
Warranty:
12 months
1
Offer with manufacturer lead time
Ships in:On Request
Best price:
Send request for price

Specifications

Switch Actuation
on end
Type Of Approach
vertical approach, 1 direction
Series Name
special format
Movement Of Operating Head
linear
Body Type
fixed
Range Of Product
OsiSense XC
Contact Operation
snap action
Product Specific Application
for severe applications
Maximum Actuation Speed
0.5 m/s
Type Of Operator
end plunger metal
Minimum Force For Tripping
18 N
Product Or Component Type
limit switch
Material
metal
Device Short Name
XC2J
Number Of Poles
1
Repeat Accuracy
0.01 mm with 1 million operating cycles
Head Type
plunger head

Contractual warranty

Warranty
18 months

Complementary

[Ui] Rated Insulation Voltage
500 VIEC 60947-5-1 || 500 VNF C 20-040 group C || 300 VCSA C22.2 No 14
Height
112-112 mm
Terminals Description Iso N°1
(13-14-11-12)OF
Short-Circuit Protection
10 A cartridge fuse gG
Electrical Durability
5000000 cycles, DC-13, 120 V, 4 W 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, 24 V, 10 W 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, 48 V, 7 W 3600 cyc/h 0.5 IEC 60947-5-1 appendix C
Positive Opening
without
Minimum Actuation Speed
0.001 m/min
Contacts Insulation Form
Za
Electrical Connection
screw-clamp terminals 1 x 0.5...2 x 2.5 mm²
Fixing Mode
by the body
Contacts Material
silver plated contacts
Mechanical Durability
30000000 cycles
Cable Entry
1 entry incorporating cable gland 6-13.5 mm
Contact Code Designation
A300, AC-15 (Ue = 240 V), Ie = 3 A 10 A EN/IEC 60947-5-1 || Q300, DC-13 (Ue = 250 V), Ie = 0.27 A EN/IEC 60947-5-1
Width
40 mm
Depth
41 mm
Net Weight
0.6 kg
Maximum Resistance Across Terminals
25 MOhm IEC 60255-7 category 3 || 25 MOhm NF C 93-050 method A

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP110614EN
Sustainable Offer Status
Green Premium product
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Environment

Product Certifications
CSA || NEMKO || DEMKO
Ik Degree Of Protection
IK08
Ambient Air Temperature For Operation
-25-70 °C
Ambient Air Temperature For Storage
-40-70 °C
Standards
VDE 0660-200 || UL 508 || EN/IEC 60947-5-1 || CSA C22.2 No 14 || IEC 60337-1
Electrical Shock Protection Class
class I IEC 60536 || class I NF C 20-030
Shock Resistance
25 gn 18 ms IEC 60068-2-27
Vibration Resistance
10 gn 10-500 Hz)IEC 60068-2-6
Protective Treatment
TC
Ip Degree Of Protection
IP65 conforming to IEC 60529 || IP657 conforming to NF C 20-010