1 / 1
thumbnail

Description

Active Mature
This XCSPL Safety Limit Switch has a stainless steel turret head rotary straight lever with an operation contact to the right or to the left, a double insulated plastic enclosure and a 1/2" NPT cable gland entry. It has 1 normally open and 1 normally closed break-before-make (slow break) contacts. Its B10D reliability data is 5 000 000. Its IP67 degree of protection makes it ideal for heavy duty use in harsh conditions. It also complies with EN/ISO 14119, EN/IEC 60204-1, EN/IEC 60947-5-1, EN/IEC 60947-5-4, UL 508, CSA C22.2 No 14 standards. When associated and correctly connected to an appropriate safety control unit, it conforms to Category 4, performance level PL e, SIL 3 as described in EN/ISO 13849-1, EN/IEC 61508.
Country of Origin
FR
Part Number
XCSPL563
Tariff Code
85365080
EAN
3389110866469
UNSPSC
39122213
Payment methods:
Best offer from:
DETrusted Automa.Net Supplier
Availability:
1 pc.
In-Stock
Updated at: 08-11-2024
Warranty:
12 months
Estimated Delivery:
On Request
Condition:
New Surplus
New Surplus - A new, unused, undamaged item without a manufacturer guarantee. The item may come without original packaging or in replacement packaging. If provided, the box may have been opened.
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies

Specifications

Contacts Type And Composition
1 NC + 1 NO
Range Of Product
Telemecanique Safety switches XCS
Cable Entry
1 entry tapped 1/2" NPT
Clamping Connection Capacity
1 x 0.5...2 x 1.5 mm² with or without cable end
Product Or Component Type
guard switch
Component Name
XCSPL
Operator Direction Information
to right or to left
Material
plastic
Head Type
turret head rotary lever
Insulation
double insulated
Contact Operation
slow-break, break before make
Type Of Operator
straight lever
Electrical Connection
terminal
Number Of Poles
2

Contractual warranty

Warranty
18 months

Complementary

Height
88-88 mm
Short-Circuit Protection
10 A cartridge fuse gG (gl)
[Ithe] Conventional Enclosed Thermal Current
10 A
Lever Material
stainless steel
Tripping Angle
5 °
Net Weight
0.095 kg
[Uimp] Rated Impulse Withstand Voltage
6 kV EN/IEC 60947-5-1
[Ui] Rated Insulation Voltage
300 VUL 508 || 300 VCSA C22.2 No 14 || 500 V 3)EN/IEC 60947-1
Positive Opening
with NC contact
Positive Opening Minimum Torque
0.25 N.m
Mechanical Durability
1000000 cycles
Safety Reliability Data
B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
Enclosure Material
polyamide PA66 fibre glass impregnated
Contact Code Designation
A300, AC-15 (Ue = 120 V, Ie = 6 A)EN/IEC 60947-5-1 || A300, AC-15 (Ue = 240 V, Ie = 3 A)EN/IEC 60947-5-1 || Q300, DC-13 (Ue = 125 V, Ie = 0.55 A)EN/IEC 60947-5-1 || Q300, DC-13 (Ue = 250 V, Ie = 0.27 A)EN/IEC 60947-5-1
Width
103 mm
Depth
30 mm
Cable Outer Diameter
7-10 mm
Minimum Torque For Tripping
0.1 N.m
Maximum Resistance Across Terminals
30 mOhm EN/IEC 60947-5-4
Safety Level
can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired IEC 61508

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP110606EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Free of Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Reach Free Of Svhc
Yes
Circularity Profile
ENVEOLI110603EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
UL || CSA || BG
Ambient Air Temperature For Operation
-25-70 °C
Standards
EN/ISO 12100 || EN/IEC 60947-5-4 || EN 1088/ISO 14119 || EN/IEC 60204-1 || CSA C22.2 No 14 || EN/IEC 60947-5-1 || UL 508
Shock Resistance
50 gn 11 ms IEC 60068-2-27
Vibration Resistance
50 gn 10-500 Hz)IEC 60068-2-6
Ip Degree Of Protection
IP67 conforming to IEC 60529
Ambient Air Temperature For Storage
-40-70 °C
Electrical Shock Protection Class
class II EN/IEC 61140
Protective Treatment
TH || TC