Schneider Electric

XMLGB05L73SBM

1 / 1
thumbnail

Description

Active Mature
Part Number
XMLGB05L73SBM
Tariff Code
9026204000
UNSPSC
39122210
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Specifications

Pressure Sensor Type
pressure transmitter
Type Of Output Signal
analogue
Diameter
22.8 mm
Range Of Product
Telemecanique Pressure sensors XM
Product Or Component Type
electronic pressure sensors
Type Of Packing
group
Pressure Sensor Name
XMLG
Controlled Fluid
air -15-125 °C) || corrosive fluid -15-125 °C) || hydraulic oil -15-125 °C) || fresh water 0-125 °C)
Analogue Output Function
0...10 V, 3 wires
Quantity Per Set
set of 25
[Us] Rated Supply Voltage
24 V DC 11.4-33 V)

Contractual warranty

Warranty
18 months

Complementary

Height
66.1 mm
Response Time On Output
< 2 ms
[Uimp] Rated Impulse Withstand Voltage
0.5 kV
Repeat Accuracy
+/- 0.1 % of the measuring range
Drift Of The Zero Point
+/- 0.015 % of measuring range/°C
Materials In Contact With Fluid
ceramic || stainless steel type AISI 303 || PPS || FPM (Viton)
Length
66.1 mm
Local Display
without
Net Weight
0.095 kg
Current Consumption
< 20 mA
Surge Withstand
1 kV 42 Ohm EN/IEC 61000-4-5 || 500 kV 12 Ohm EN/IEC 61000-4-5
Mechanical Durability
10000000 cycles
Operating Position
any position
Measurement Accuracy
+/- 0.3 % of the measuring range
Protection Type
reverse polarity || load short-circuit
Electrical Circuit Type
control circuit
Drift Of The Sensitivity
+/- 0.015 % of measuring range/°C
Pressure Setting Range
0-500 bar

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Reach Regulation
Free of Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Reach Free Of Svhc
Yes
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
EAC || CSA C22.2 No 14 || UL 508
Resistance To Conducted Disturbances
30 V 0.15-80 Hz)EN/IEC 61000-4-6
Ambient Air Temperature For Operation
-15-85 °C
Resistance To Electromagnetic Fields
200 V/m 80-1000 Hz EN/IEC 61000-4-3
Standards
CE || EN/IEC 61326-2-3
Shock Resistance
25 gn 11 ms EN/IEC 60068-2-27
Resistance To Magnetic Fields
30 A/m 50 Hz EN/IEC 61000-4-8
Vibration Resistance
20 gn 9-2000 Hz)EN/IEC 60028-2-6
Ip Degree Of Protection
IP66 conforming to EN/IEC 60529 || IP67 conforming to EN/IEC 60529
Nema Degree Of Protection
NEMA 4
Ambient Air Temperature For Storage
-40-85 °C
Resistance To Electrostatic Discharge
15 kV in air EN/IEC 61000-4-2 || 8 kV on contact EN/IEC 61000-4-2
Protective Treatment
TC
Resistance To Fast Transients
4 kV EN/IEC 61000-4-4

Documents

Data Sheet

Download