TE Connectivity
1461077-6
1 / 5
- Part Number
- 1461077-6
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Packaging Features
- Packaging Method
- Box & Tray
- Packaging Method
- Tray
Dimensions
- Product Width
- 10.2 mm
- Width Class (Mechanical)
- 10 – 12 mm
- Product Width
- .4 in
- Insulation Clearance Class
- 2.5 – 4 mm
- Product Length
- 18.2 mm
- Product Length
- .717 in
- Insulation Clearance Between Contact & Coil
- 7.7 mm
- Height Class (Mechanical)
- 14 – 15 mm
- Insulation Clearance Between Contact & Coil
- .303 in
- Product Height
- 14.7 mm
- Product Height
- .579 in
- Length Class (Mechanical)
- 16 – 20 mm
Mechanical Attachment
- Relay Mounting Type
- Printed Circuit Board
Usage Conditions
- Environmental Category of Protection
- RTII
- Environmental Ambient Temperature Class
- 50 – 70 °C
- Environmental Ambient Temperature (Max)
- 70 °C
- Environmental Ambient Temperature (Max)
- 158 °F
Contact Features
- Contact Arrangement
- 1 Form A (NO)
- Contact Current Class
- 5 – 10 A
- Contact Current Class
- 16 A
- Contact Current Rating (Max)
- 10 A
- Contact Material
- Ag
- Contact Number of Poles
- 1
- Terminal Type
- PCB-THT
Body Features
- Product Weight
- 9 g
- Insulation Special Features
- Tracking Index of Relay Base PTI250
- Product Weight
- .318 oz
Product Type Features
- Power Relay Type
- Standard
Electrical Characteristics
- Contact Limiting Breaking Current
- 10 A
- Coil Magnetic System
- Monostable, DC
- Coil Power Rating Class
- 400 – 500 mW
- Coil Power Rating DC
- 450 mW
- Coil Resistance
- 5120 Ω
- Coil Special Features
- UL Coil Insulation Class B
- Coil Voltage Rating
- 48 VDC
- Contact Switching Load (Min)
- 100mA @ 5V
- Contact Switching Voltage (Max)
- 277 VAC
- Contact Switching Voltage (Max)
- 30 VDC
- Contact Voltage Rating
- 250 VAC
- Contact Voltage Rating
- 30 VDC
- Insulation Initial Dielectric Between Contacts & Coil
- 4000 Vrms
- Contact Limiting Continuous Current
- 10 A
- Insulation Creepage Between Contact & Coil
- 9.4 mm
- Insulation Creepage Between Contact & Coil
- .37 in
- Contact Limiting Making Current
- 10 A
- Insulation Creepage Class
- 5.5 – 8 mm
- Contact Limiting Short-Time Current
- 10 A
- Insulation Initial Dielectric Between Open Contacts
- 750 Vrms
- Insulation Initial Dielectric Between Coil & Contact Class
- 3500 – 4000 V
Documents
Data Sheet
DownloadOther Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther