TE Connectivity
6-1462037-8
1 / 1
- Part Number
- 6-1462037-8
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Signal Characteristics
- Insertion Loss (HF Parameter)
- -.33dB @ 900MHz, -.03dB @ 100MHz
- Isolation (HF Parameter)
- -37dB @ 100MHz, -18.8dB @ 900MHz
Other
- Additional Features
- J Leg
Packaging Features
- Packaging Method
- Reel
Dimensions
- Length (in)
- 10
- Width
- 6 mm [ .236 in ]
- Length Class (Mechanical)
- 0 – 10 mm
- Height Class (Mechanical)
- 0 – 6 mm
- Dimensions (L x W x H) (Approximate)
- 10 x 6 x 5.65 mm [ .393 x .236 x .222 in ]
- Width Class (Mechanical)
- 0 – 6 mm
- Height
- 5.6 mm [ .221 in ]
Mechanical Attachment
- Mounting Type
- Printed Circuit Board
Usage Conditions
- Environmental Category of Protection
- RTV
- Environmental Ambient Temperature (Max)
- 85 °C [ 85 °F ]
- Environmental Ambient Temperature Class
- 70 – 85°C
Contact Features
- Contact Number of Poles
- 2
- Contact Material
- PdRu
- Contact Current Class
- 0 – 2 A
- Contact Arrangement
- 2 Form C (CO)
- Contact Special Features
- Bifurcated/Twin Contacts
- Contact Current Rating (A)
- 2
- Terminal Type
- PCB-SMT
- Contact Plating Material
- Gold
Operation/Application
- Performance Type
- Standard
Body Features
- Insulation Special Features
- 2500V Initial Surge Withstand Voltage between Contacts & Coil
Product Type Features
- Relay Type
- IM Relay
- Product Type
- Relay
Electrical Characteristics
- Voltage Standing Wave Ration (HF Parameter)
- 1.06 @ 100MHz, 1.49 @ 900Mhz
- Insulation Initial Dielectric Between Adjacent Contacts (Vrms)
- 1000
- Coil Type
- Bistable
- Coil Magnetic System
- Bistable, 1 Coil
- Coil Voltage Rating (VAC)
- 12
- Contact Limiting Breaking Current (A)
- 2
- Actuating System
- DC
- Contact Limiting Making Current (A)
- 2
- Contact Switching Load (Min)
- .1mA @ .0001V
- Contact Limiting Short-Time Current (A)
- 2
- Insulation Initial Resistance (MΩ)
- 1000000
- Coil Resistance (Ω)
- 1440
- Coil Power Rating (DC) (mW)
- 100
- Insulation Initial Dielectric Between Contacts and Coil (Vrms)
- 1800
- Contact Switching Voltage (Max)
- 250 VAC [ 220 VDC ]
- Insulation Initial Dielectric Between Open Contacts (Vrms)
- 1000
- Contact Limiting Continuous Current (A)
- 2
- Coil Power Rating Class
- 50 – 300mW
- Contact Voltage Rating
- 250 VAC [ 220 VDC ]
- Insulation Initial Dielectric Between Coil/Contact Class
- 1500 V – 2500 VA
Other Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther