TE Connectivity
8-1415537-9
1 / 1
- Part Number
- 8-1415537-9
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Other
- Comment
- Well suited for emergency shut-off, machine control, elevator and escalator control, light barrier control
Packaging Features
- Packaging Method
- Tube, Tube/Box
Dimensions
- Length Class (Mechanical)
- 50 – 60 mm
- Insulation Clearance Between Contact and Coil
- 5.5 mm [ .217 in ]
- Length
- 55 mm [ 2.167 in ]
- Insulation Clearance Class
- 5 – 8 mm
- Width
- 16.51 mm [ .65 in ]
- Width Class (Mechanical)
- 16 – 20 mm
- Height
- 16.5 mm [ .65 in ]
- Height Class (Mechanical)
- 16 – 20 mm
Mechanical Attachment
- Mounting Type
- Printed Circuit Board
Usage Conditions
- Environmental Ambient Temperature (Max)
- 70 °C [ 158 °F ]
- Environmental Ambient Temperature Class
- -25 – 70°C
- Environmental Category of Protection
- RTIII
Contact Features
- Terminal Type
- PCB-THT
- Contact Number of Poles
- 6
- Contact Arrangement
- 5 Form A (NO) + 1 Form B (NC)
- Contact Current Rating (A)
- 8
- Contact Special Features
- Force Guided Contacts
- Contact Current Class
- 5 – 10 A
- Contact Plating Material
- Gold Flash
- Contact Material
- AgSnO2
Body Features
- Weight
- 30 g [ 1.058 oz ]
Product Type Features
- Product Type
- Relay
- Relay Type
- Force Guided Relay SR6 A/B/C/V
Electrical Characteristics
- Insulation Initial Dielectric Between Adjacent Contacts (Vrms)
- 3000
- Insulation Initial Dielectric Between Coil/Contact Class
- 3500 – 4000 V
- Contact Limiting Short-Time Current (A)
- 8
- Coil Voltage Rating (VDC)
- 9
- Contact Switching Load (Min)
- 10mA @ 5V
- Insulation Initial Dielectric Between Contacts and Coil (Vrms)
- 4000
- Contact Limiting Making Current (A)
- 8
- Contact Limiting Continuous Current (A)
- 8
- Coil Power Rating (DC) (mW)
- 802
- Coil Power Rating Class (mW)
- 800 – 1000
- Insulation Creepage Class
- 3 – 5.5 mm
- Coil Current
- 89.109
- Insulation Creepage Between Contact and Coil
- 5.5 mm [ .217 in ]
- Insulation Initial Dielectric Between Open Contacts (Vrms)
- 1500
- Coil Resistance (Ω)
- 101
- Contact Switching Voltage (Max) (VAC)
- 400
- Contact Limiting Breaking Current (A)
- 8
- Contact Voltage Rating (VAC)
- 250
- Coil Magnetic System
- Monostable, DC
Other Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther