TE Connectivity
RM302024
1 / 1
- Part Number
- RM302024
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Other
- Additional Features
- Mechanical Indicator
- Accessories/Socket Type
- DIN Rail Socket, PCB Socket, Panel Socket
Packaging Features
- Packaging Method
- Tray/Box
Dimensions
- Length
- 38.5 mm [ 1.515 in ]
- Height
- 48.5 mm [ 1.909 in ]
- Width Class (Mechanical) (mm)
- 30 – 40
- Insulation Clearance Class
- 2.5 – 4mm
- Height Class (Mechanical) (mm)
- 40 – 50
- Width
- 35.5 mm [ 1.398 in ]
- Length Class (Mechanical) (mm)
- 35 – 40
- Insulation Clearance Between Contact and Coil
- 4 mm [ .157 in ]
Mechanical Attachment
- Mounting Type
- Socket
Usage Conditions
- Environmental Ambient Temperature Class
- 50 – 70°C
- Environmental Category of Protection
- RTI
- Environmental Ambient Temperature (Max)
- 60 °C [ 140 °F ]
Contact Features
- Contact Number of Poles
- 3
- Terminal Type
- Plug-In, Quick Connect
- Contact Current Class
- 5 – 10 A, Less Than 16A
- Contact Arrangement
- 3 Form C (CO)
- Contact Material
- AgCdO
- Contact Current Rating (A)
- 10
Body Features
- Insulation Special Features
- 4000V Initial Surge Withstand Voltage between Contacts and Coil
- Weight
- 81 g [ 2.859 oz ]
Product Type Features
- Relay Type
- Power Relay RM 2/3/7
- Product Type
- Relay
Electrical Characteristics
- Contact Limiting Continuous Current (A)
- 10
- Insulation Initial Dielectric Between Coil/Contact Class
- 1500 V – 2500 VA
- Contact Switching Voltage (Max) (VAC)
- 440
- Coil Power Rating Class
- 1 – 1.5 W
- Coil Special Features
- UL Coil Insulation Class B
- Insulation Creepage Class
- >8mm
- Insulation Creepage Between Contact and Coil
- 14.9 mm [ .587 in ]
- Contact Limiting Short-Time Current (A)
- 10
- Coil Resistance (Ω)
- 475
- Contact Voltage Rating (VAC)
- 400
- Contact Limiting Breaking Current (A)
- 10
- Coil Voltage Rating (VDC)
- 24
- Contact Limiting Making Current (A)
- 40
- Insulation Initial Dielectric Between Contacts and Coil (Vrms)
- 2500
- Coil Power Rating (DC) (mW)
- 1200
- Coil Magnetic System
- Monostable, DC
- Insulation Initial Dielectric Between Adjacent Contacts (Vrms)
- 2500
- Contact Switching Load (Min)
- 100mA @ 24V
- Insulation Initial Dielectric Between Open Contacts (Vrms)
- 1500
Other Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther