Dimensions
- Length Class (Mechanical) (mm)
- 35 – 40
- Insulation Clearance Class
- 2.5 – 4mm
- Insulation Clearance Between Contact and Coil
- 4 mm [ .157 in ]
- Width
- 35.5 mm [ 1.398 in ]
- Height Class (Mechanical) (mm)
- 40 – 50
- Height
- 48.5 mm [ 1.909 in ]
- Width Class (Mechanical) (mm)
- 30 – 40
- Length
- 38.5 mm [ 1.515 in ]
Mechanical Attachment
- Mounting Type
- Bracket
Usage Conditions
- Environmental Category of Protection
- RTI
- Environmental Ambient Temperature (Max)
- 50 °C [ 122 °F ]
- Environmental Ambient Temperature Class
- 0 – 50°C
Contact Features
- Contact Current Rating (A)
- 16
- Contact Current Class
- 10 – 20 A, Greater Than 16A
- Terminal Type
- Plug-In, Quick Connect
- Contact Arrangement
- 2 Form A (NO)
- Contact Number of Poles
- 2
- Contact Special Features
- 3mm Contact Gap
- Contact Material
- AgCdO
Body Features
- Weight
- 81 g [ 2.859 oz ]
- Insulation Special Features
- 5000V Initial Surge Withstand Voltage between Contacts and Coil
Product Type Features
- Relay Type
- Power Relay RM 5/6/B
- Product Type
- Relay
Electrical Characteristics
- Coil Voltage Rating (VAC)
- 230
- Coil Resistance (Ω)
- 7500
- Insulation Initial Dielectric Between Contacts and Coil (Vrms)
- 2500
- Insulation Creepage Between Contact and Coil
- 14.9 mm [ .587 in ]
- Coil Special Features
- UL Coil Insulation Class B
- Coil Power Rating Class
- 2 – 3 VA
- Contact Limiting Making Current (A)
- 30
- Contact Limiting Breaking Current (A)
- 16
- Insulation Initial Dielectric Between Adjacent Contacts (Vrms)
- 2500
- Insulation Initial Dielectric Between Open Contacts (Vrms)
- 2500
- Coil Magnetic System
- Monostable, AC
- Contact Switching Load (Min)
- 100mA @ 24V
- Contact Switching Voltage (Max) (VAC)
- 440
- Contact Limiting Continuous Current (A)
- 16
- Contact Voltage Rating (VAC)
- 400
- Contact Limiting Short-Time Current (A)
- 16
- Insulation Initial Dielectric Between Coil/Contact Class
- 1500 V – 2500 VA
- Insulation Creepage Class
- >8mm
- Coil Power Rating (AC) (VA)
- 3
Other Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther