TE Connectivity
V23047A1018A511
1 / 1
- Part Number
- V23047A1018A511
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Other
- Comment
- Well suited for emergency shut-off, machine control, elevator and escalator control, light barrier control
Packaging Features
- Packaging Method
- Tube, Tube/Box
Dimensions
- Length
- 29 mm [ 1.142 in ]
- Height
- 25.5 mm [ 1.004 in ]
- Width Class (Mechanical)
- 12 – 16 mm
- Width
- 12.6 mm [ .496 in ]
- Height Class (Mechanical)
- 25 – 30 mm
- Length Class (Mechanical)
- 25 – 30 mm
- Insulation Clearance Class
- 5 – 8 mm
- Insulation Clearance Between Contact and Coil
- 8 mm [ .315 in ]
Mechanical Attachment
- Mounting Type
- Printed Circuit Board
Usage Conditions
- Environmental Category of Protection
- RTIII
- Environmental Ambient Temperature (Max)
- 70 °C [ 158 °F ]
- Environmental Ambient Temperature Class
- -25 – 70°C
Contact Features
- Contact Special Features
- Force Guided Contacts
- Contact Arrangement
- 1 Form A (NO) + 1 Form B (NC)
- Contact Current Class
- 5 – 10 A
- Contact Material
- AgNi
- Terminal Type
- PCB-THT
- Contact Current Rating (A)
- 6
- Contact Number of Poles
- 2
Body Features
- Weight
- 20 g [ .706 oz ]
Product Type Features
- Product Type
- Relay
- Relay Type
- Force Guided Relay SR2M
Electrical Characteristics
- Coil Resistance (Ω)
- 483
- Coil Current
- 37.267
- Contact Switching Load (Min)
- 10mA @ 5V
- Insulation Initial Dielectric Between Adjacent Contacts (Vrms)
- 3000
- Coil Power Rating Class (mW)
- 600 – 800
- Insulation Initial Dielectric Between Contacts and Coil (Vrms)
- 4000
- Insulation Creepage Class
- 5.5 – 8 mm
- Insulation Initial Dielectric Between Coil/Contact Class
- 3500 – 4000 V
- Contact Switching Voltage (Max) (VAC)
- 400
- Insulation Creepage Between Contact and Coil
- 8 mm [ .315 in ]
- Coil Magnetic System
- Monostable, DC
- Coil Voltage Rating (VDC)
- 18
- Insulation Initial Dielectric Between Open Contacts (Vrms)
- 1500
- Contact Limiting Short-Time Current (A)
- 6
- Contact Limiting Breaking Current (A)
- 6
- Contact Limiting Continuous Current (A)
- 6
- Contact Limiting Making Current (A)
- 6
- Coil Power Rating (DC) (mW)
- 671
- Contact Voltage Rating (VAC)
- 250
Other Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther