Honeywell HVFDSB3A0250G231/U

VFD with Bypass and Disconnect, SmartVFD BYPASS, 208Vac, 25 HP, Graphical, NEMA 12 Enclosure

1 / 3
Honeywell HVFDSB3A0250G231/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 208Vac, 25 HP, Graphical, NEMA 12 Enclosure — Variadores y convertidores de frecuencia
Imagen de catálogo del fabricante
Honeywell HVFDSB3A0250G231/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 208Vac, 25 HP, Graphical, NEMA 12 Enclosure — Variadores y convertidores de frecuencia
Imagen de catálogo del fabricante
Honeywell HVFDSB3A0250G231/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 208Vac, 25 HP, Graphical, NEMA 12 Enclosure — Variadores y convertidores de frecuencia
Imagen de catálogo del fabricante
Honeywell HVFDSB3A0250G231/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 208Vac, 25 HP, Graphical, NEMA 12 Enclosure — Variadores y convertidores de frecuencia
Honeywell HVFDSB3A0250G231/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 208Vac, 25 HP, Graphical, NEMA 12 Enclosure — Variadores y convertidores de frecuencia
Honeywell HVFDSB3A0250G231/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 208Vac, 25 HP, Graphical, NEMA 12 Enclosure — Variadores y convertidores de frecuencia

Descripción del producto

The variable frequency drive (VFD) with model designation SmartVFD BYPASS is designed to optimize energy efficiency by modulating the operation of HVAC system components such as fans and pumps. With an input voltage of 208 V AC and a power rating of 25 HP, this drive integrates seamlessly with building automation systems (BAS) or can function independently using its internal PID capabilities.

This VFD features a three-contactor bypass with auto bypass functionality, ensuring reliable operation while minimizing downtime. The NEMA 12 enclosure provides suitable protection for various environments, while the graphical interface facilitates quick commissioning through intuitive controls. Key specifications include continuous output current rated at 75 A, and it supports both variable torque applications.

Additionally, the device is equipped with an EMC filter to enhance performance and compatibility, and it meets several regulatory standards, including CE and EN 61800-5-1. The operational temperature ranges from 14 °F to 104 °F, with a maximum relative humidity of 95%. The VFD is also designed for easy installation with features such as input disconnect and drive input fuses.

¿Necesita más información?

Llámanos al:+48 17 778 34 19
  • Consigue plazos de pago de hasta 90 días de 500+ proveedores.
  • Descuentos de reventa de hasta el 40%!
Enviar solicitud de precio
Formas de pago:
Solicite un presupuesto y le enviaremos información sobre disponibilidad y precio.

Especificaciones

Type of RFI Filter
EMC Filter
Relay Rated Load
Max load: 250Vac/2A- 250Vdc/0.4A
Regulatory Approvals
CE ; EN 61800-5-1 ; cUL
Reference Output Voltage
10 Vdc- max load 10 mA
Pilot Lights
Yes
Peak Current
IS- 2s/20s

Documentos

Hoja de datos

Hoja de datos para Honeywell HVFDSB3A0250G231/U, incluyendo especificaciones y características.

Descargar hoja de datos
TraceParts

Modelos CAD

Modelo CAD 3D y planos técnicos, listos para tu software de diseño.

Descargar modelo CAD
Panel de análisis AutomaINSIGHTS de HVFDSB3A0250G231/U

Información de mercado de HVFDSB3A0250G231/U

Obtenga análisis en tiempo real y datos de mercado sobre HVFDSB3A0250G231/U y otros productos de la categoría Variadores y convertidores de frecuencia para optimizar sus decisiones de compra.

  • Datos de disponibilidad de existencias en tiempo real de más de 700 distribuidores MRO de Europa y EE.UU.
  • Análisis de precios por estado (nuevos, usados, reacondicionados) con precios medios de mercado
  • Supervisión de la disponibilidad de componentes críticos para evitar paradas de producción