iEM3455 energy meter - Modbus - 1 DI - 1 DO - multi-tariff - LVCT - CTEP 100A
A9MEM3455C1
  • Consigue plazos de pago de hasta 90 días de 500+ proveedores.
  • Descuentos de reventa de hasta el 40%!
Registrate
Enviar solicitud de precio
1
Formas de pago:
Solicite un presupuesto y le enviaremos información sobre disponibilidad y precio.

Additional Information

Part Number
A9MEM3455C1
UNSPSC
39121603
Tariff Code
9028300000
Country of Origin
CN

Specifications

Product Or Component Type
energy meter
Product Name
Acti9 iEM3000
Range
Acti9
Device Short Name
iEM3455

Complementary

Network Frequency
60 Hz || 50 Hz
Communication Port Support
screw terminal block RS485
Output Voltage
5...40 V DC@50 mA
Sampling Rate
32 samples/cycle
Number Of Outputs
1 digital (static)
Mounting Support
DIN rail
Maximum Value Measured
99999999.9 kWh || 99999999 MWh
Type Of Measurement
active and reactive energy || active and reactive power || current || voltage
Communication Port Protocol
Modbus RTU 9.6, 19.2 and 38.4 kbauds even/odd or none
Product Certifications
CE IEC 61010-1 safety) || CE EN 61557-12 power monitor) || CE EN/IEC 61326-1 EMC) || UKCA BS EN 61010-1 safety) || UKCA BS EN 61557-12 power monitor) || UKCA BS EN 61326-1 EMC) || cULus UL 61010-1 safety) || cULus EN 61010-1 safety) || KZ || RCM
Number Of Inputs
1 digital 0...5 V/11...40 V 24 V DC
Measurement Current
1-32767000 mA
Wire Stripping Length
input/output circuit: 6 mm || voltage circuit: 8 mm || current circuit: 8 mm || communication: 7 mm
Connections - Terminals
current circuit screw terminals 6-6 mm² || voltage circuit screw terminals 2.5-2.5 mm² || input/output circuit screw terminals 1.5-1.5 mm² || communication screw terminals 2.5-2.5 mm²
Information Displayed
tariff 4)
Mounting Mode
clip-on
Local Signalling
Green indicator light power ON || Yellow flashing LED accuracy checking || alarm overload || Yellow indicator light communications are active on the Modbus port (Modbus)
Technology Type
electronic
Poles Description
3P + N || 1P + N || 3P
Analogue Input Type
split core current transducer 0.333 V or 1 V
Display Type
LCD display
Tightening Torque
input/output circuit 0.5-0.5 N.m Philips || voltage circuit 0.5-0.5 N.m Philips || current circuit 0.8-0.8 N.m pozidriv || communication 0.5-0.5 N.m Philips
Device Application
sub billing || multi-tariff || partial meter
Accuracy Class
class 0.5S active energy IEC 62053-22 || class 0.5S active energy ANSI C12.20
Metering Type
active, reactive, apparent energy (signed, four quadrant)
Rated Voltage
100-277 V +/- 20 % || 173-480 V +/- 20 %

Environment

Ik Degree Of Protection
IK08
Height
87 mm
Ambient Air Temperature For Operation
-25-70 °C - IEC
Pollution Degree
2
9 Mm Pitches
10
Color
White
Ambient Air Temperature For Storage
-40-85 °C
Relative Humidity
5-95 % 36-36 °C
Ip Degree Of Protection
front panel IP40 IEC 60529 || body IP20 IEC 60529
Width
90 mm
Depth
69 mm
Operating Altitude
< 9842.52 ft (3000 m)

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP111276EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Circularity Profile
ENVEOLI111261EN_V1
Eu Rohs Directive
Compliant with Exemptions

Documentos

Data Sheet

Descargar

Productos relacionados