¿Necesita más información?
Llámanos al:+48 17 778 34 19
Schneider Electric ABLM1A24012
Regulated Power Supply, 100 to 240V AC, 24V, 1.2A, single phase, Modular
1 / 5
Descripción del producto
Ciclo de vida:
This ABLM regulated switch mode power supply (SMPS) supplies direct current voltage. It has a rated input of 100V to 240V AC, a rated output current of 1,25A at 24V DC and a rated power output of 30W. It is ideal for supplying DC voltage necessary for automation equipment designed for applications in industrial, commercial and residential applications such as conveying, packaging, control, food & beverage, mining, oil & gas and water. It installs on omega rail or fixing by screw. Its width is 36mm, its height is 91mm, its depth is 55,6mm. It ensures a protection against overloads and short-circuits with automatic restart after the source of overload/short-circuit has been corrected. It weighs 0.170kg. It is a power supply for industrial use, rail mounting. It conforms to EN62368-1, ENIEC61010-1/2-201, ENIEC61204-3, EN61000-6-1/2/3/4, EN61000-3-2-3, UL62368-1, UL61010-2-201/-1-201, CSAC22.2No62368-1/No61010-2-201/No61010-1 standards, and certified by CE, CUL listed/recognized, RCM, CBscheme. The Acti9 iC60 range of Miniature Circuit Breakers is recommanded for its protection. The type of protection is 4A, B or C-curve. It has in the front face a LED indicating presence of DC output voltage, and a QR code for access to the latest technical documentation. Thanks to their modular housing, they can be installed either in enclosures or industrial panels by clipping on omega (DIN) rail. It brings energy to your automated systems. Designed for simple machines and applications,...
¿Necesita más información?
Llámanos al:+48 17 778 34 19
Métodos de pago:
Detalles de la oferta
- Oferta de:
Proveedor de confianza — Rumanía, miembro desde 2023, 1–4 empleados
- Disponibilidad:
- Bajo pedidoPlazo de entrega: 21 días
- Garantía:
- No indicada
- Condición:
- Nuevos excedentes
Nuevos excedentes - Un artículo nuevo, sin usar, sin daños y sin garantía del fabricante. El artículo puede venir sin embalaje original o en embalaje de reemplazo. Si se proporciona, es posible que la caja haya sido abierta.
El Vendedor es responsable de enviar el producto y facturar
Especificaciones
- Marca
- Schneider Electric
- Standards
- IEC 62368-1 || EN/IEC 61010-1 || EN 61010-2-201 || EN/IEC 61204-3 || IEC 61000-6-1 || IEC 61000-6-2 || IEC 61000-6-3 || IEC 61000-6-4 || IEC 61000-3-2 || EN 61000-3-3 || UL 62368-1 || UL 61010-1 || UL 61010-2-201 || CSA C22.2 No 62368-1 || CSA C22.2 No 61010-1 || CSA C22.2 No 61010-2-201 || EN/IEC 62368-1
- Ambient Air Temperature For Operation
- -25-55 °C without current derating mounting position A < 6561.68 ft (2000 m) || 55-70 °C with current derating of 2.67 % per °C mounting position A < 6561.68 ft (2000 m)
- Product Certifications
- CE || cUL Listed || cUL Recognized || RCM || CB Scheme || EAC || KC || NEC class 2
- Pollution Degree
- 2
- Electromagnetic Compatibility
- immunity to electrostatic discharge - test level: 8 kV (contact discharge) conforming to IEC 61000-4-2 || immunity to electrostatic discharge - test level: 15 kV (air discharge) conforming to IEC 61000-4-2 || electromagnetic field immunity test - test level: 15 V/m (80 MHz...2 GHz) conforming to IEC 61000-4-3 || electromagnetic field immunity test - test level: 5 V/m (2...2.7 GHz) conforming to IEC 61000-4-3 || electromagnetic field immunity test - test level: 5 V/m (2.7...6 GHz) conforming to IEC 61000-4-3 || immunity to fast transients - test level: 4 kV (on input-output) conforming to IEC 61000-4-4 || surge immunity test - test level: 4 kV (between power supply and earth) conforming to IEC 61000-4-5 || surge immunity test - test level: 3 kV (between phases) conforming to IEC 61000-4-5 || immunity to conducted disturbances - test level: 15 V (0.15...80 MHz) conforming to IEC 61000-4-6 || immunity to magnetic fields - test level: 30 A/m (50...60 Hz) conforming to IEC 61000-4-8 || immunity to voltage dips - test level: 100 % (1 cycle) conforming to IEC 61000-4-11 || immunity to voltage dips - test level: 60 % (10 cycles) conforming to IEC 61000-4-11 || immunity to voltage dips - test level: 30 % (25 cycles) conforming to IEC 61000-4-11 || disturbing field emission conforming to EN 55016-2-3 || limits for harmonic current emissions conforming to IEC 61000-3-2 || conforming to EN 55016-1-2 || conforming to EN 55016-2-1
- Shock Resistance
- 150 m/s² 11 ms
Ofertas disponibles
(4)| Condición | Disponibilidad | Proveedor | Garantía | Acción | |
|---|---|---|---|---|---|
| Condición Nuevos excedentes | Disponibilidad Bajo pedidoPlazo de entrega: 21 días | Proveedor | Garantía No indicada | ||
| Condición Nuevo Precintado de Fábrica | Disponibilidad 5 uds. Actualizado el: 20-09-2026En stock | Proveedor | Garantía 24 meses | ||
| Condición Nuevo Precintado de Fábrica | Disponibilidad Bajo pedidoPlazo de entrega por confirmar | Proveedor | Garantía No indicada | ||
| Condición Nuevo Precintado de Fábrica | Disponibilidad Bajo pedidoPlazo de entrega por confirmar | Proveedor | Garantía 12 meses |
Oferta con plazo de entrega del fabricante
Directamente del fabricante, con un plazo de entrega confirmado, predecible y totalmente transparente.
Documentos
Hoja de datos
Hoja de datos para Schneider Electric ABLM1A24012, incluyendo especificaciones y características.
Descargar hoja de datos
Modelos CAD
Modelo CAD 3D y planos técnicos, listos para tu software de diseño.
Descargar modelo CAD
Datos del producto actualizados: 22-08-2026

Información de mercado de ABLM1A24012
Obtenga análisis en tiempo real y datos de mercado de ABLM1A24012 y productos similares para optimizar sus decisiones de compra.
- Datos de disponibilidad de existencias en tiempo real de más de 700 distribuidores MRO de Europa y EE.UU.
- Análisis de precios por estado (nuevos, usados, reacondicionados) con precios medios de mercado
- Supervisión de la disponibilidad de componentes críticos para evitar paradas de producción