Regulated Power Supply, 100 to 240V AC, 48V, 2.5A, single phase, Optimized
ABLS1A48025
  • Consigue plazos de pago de hasta 90 días de 500+ proveedores.
  • Descuentos de reventa de hasta el 40%!
Registrate
Enviar solicitud de precio
1
Formas de pago:
Un total de 16 Parts In-Stock de 18 Distributors
Oferta con plazo de entrega del fabricante
Entrega:1 - 2 días laborables
El mejor precio:
€51.94

Additional Information

Part Number
ABLS1A48025
UNSPSC
39121004
Tariff Code
8504409520
Country of Origin
TH

Complementary

Output Coupling
parallel
Height
123.6 mm
Residual Ripple
< 150 mV
Status Led
1 LED (Green) output voltage
Holding Time
> 20 ms 115 V AC || > 40 ms 230 V AC
Efficiency At Full Load
85...264 V AC without temperature derating || 120...375 V DC without temperature derating || 85…120 V DC with temperature derating
Earthing System
TN || TT || IT
Connections - Terminals
screw connection 0.5...4 mm², AWG 20...AWG 12) without wire end ferrule output || screw connection 0.5...2.5 mm², AWG 20...AWG 14) with wire end ferrule output || screw connection 0.75...4 mm², AWG 18...AWG 12) without wire end ferrule input || screw connection 0.75...4 mm², AWG 18...AWG 12) with wire end ferrule input
Dielectric Strength
3000 V AC with input to output
Network Frequency Limits
50-60 Hz
Current Consumption
< 2.5 A 115 V AC || < 1.4 A 230 V AC || < 1.3 A 140 V DC
Supply
SELV IEC 60950-1 || SELV IEC 60204-1 || SELV IEC 60364-4-41
Net Weight
0.55 kg
Maximum Leakage Current
1 mA 240 V AC
Input Protection Type
integrated fuse (not interchangeable) 4 A || external protection (recommended) 20 A Curve C || external protection (recommended) 13 A Curve C
Output Protection Type
against overload and short-circuits automatic reset || against over temperature manual reset || against overvoltage manual reset
Service Life
10 year(s)
Meantime Between Failure [Mtbf]
700000 h at 25 °C, full load conforming to SR 332
Power Dissipation In W
23 W
Output Voltage Limits
44...56 V
Mounting Support
top hat type TH35-15 rail IEC 60715 || top hat type TH35-7.5 rail IEC 60715 || double-profile DIN rail
Load Capacitance
4000 µF
Response Time
< 1 s
Line And Load Regulation
< 0.5 % network 0 to 100 % load at 25 °C || < 1 % network full voltage range in line at 25 °C
Width
40 mm
Overvoltage Category
II
Inrush Current
30.0 A 115 V || 60.0 A 230 V
Efficiency
85 % 115 V AC || 88 % 230 V AC
Depth
117.6 mm
Power Factor
0.55 at 115 V AC || 0.45 at 230 V AC

Specifications

Range Of Product
Modicon Power Supply
Output Voltage
48 V DC
Product Or Component Type
power supply
Power Supply Type
regulated switch mode
Input Voltage
100...240 V AC single phase || 100...240 V AC phase to phase || 140...340 V DC
Power Supply Output Current
2.5 A
Kw Rating
120 W
Enclosure Material
Aluminum

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP2007005EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Circularity Profile
ENVEOLI2007005EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Standards
IEC 62368-1 || EN/IEC 61204-3 || IEC 61000-6-1 || IEC 61000-6-2 || IEC 61000-6-3 || IEC 61000-6-4 || IEC 61000-3-2 || EN 61000-3-3 || UL 62368-1 || CSA C22.2 No 62368-1 || UL 508 || CSA C22.2 No. 107.1 || EN/IEC 62368-1
Ambient Air Temperature For Operation
-20--10 °C with current derating of 2 % per °C mounting position A < 6561.68 ft (2000 m) || -10-40 °C without derating mounting position A 115 V AC < 6561.68 ft (2000 m) || -10-50 °C without derating mounting position A 230 V AC < 6561.68 ft (2000 m) || 40-70 °C with current derating of 1.67 % per °C mounting position A 115 V AC < 6561.68 ft (2000 m) || 50-70 °C with current derating of 2.5 % per °C mounting position A 230 V AC < 6561.68 ft (2000 m)
Product Certifications
CE || cUL Listed || cUL Recognized || RCM || CB Scheme || EAC || KC
Pollution Degree
2
Electromagnetic Compatibility
immunity to electrostatic discharge - test level: 8 kV (contact discharge) conforming to IEC 61000-4-2 || immunity to electrostatic discharge - test level: 15 kV (air discharge) conforming to IEC 61000-4-2 || immunity to conducted RF disturbances - test level: 15 V/m (80 MHz...2 GHz) conforming to IEC 61000-4-3 || immunity to conducted RF disturbances - test level: 5 V/m (2...2.7 GHz) conforming to IEC 61000-4-3 || immunity to conducted RF disturbances - test level: 5 V/m (2.7...6 GHz) conforming to IEC 61000-4-3 || immunity to fast transients - test level: 4 kV (on input-output) conforming to IEC 61000-4-4 || surge immunity test - test level: 4 kV (between power supply and earth) conforming to IEC 61000-4-5 || surge immunity test - test level: 3 kV (between phases) conforming to IEC 61000-4-5 || immunity to conducted RF disturbances - test level: 15 V (0.15...80 MHz) conforming to IEC 61000-4-6 || immunity to magnetic fields - test level: 30 A/m (50...60 Hz) conforming to IEC 61000-4-8 || immunity to voltage dips conforming to IEC 61000-4-11 || disturbing field emission conforming to EN 55016-2-3 || limits for harmonic current emissions conforming to IEC 61000-3-2 || conforming to EN 55016-1-2 || conforming to EN 55016-2-1
Shock Resistance
150 m/s² 11 ms
Vibration Resistance
3 mm 2-9 Hz)IEC 60068-2-6 || 10 m/s² 9-200 Hz)IEC 60068-2-6
Ip Degree Of Protection
IP20
Operating Altitude
< 5000 m
Electrical Shock Protection Class
class I
Electromagnetic Emission
conducted emissions IEC 61000-6-3 || radiated emissions IEC 61000-6-4

Documentos

Data Sheet

Descargar

Modelos CAD

Rastrear piezas
Rastrear piezas
Descargar

Productos relacionados