Schneider Electric
AP8858
APC NetShelter Metered Rack PDU, 0U, 1PH, 3.3kW 208V 16A or 3.7kW 230V 16A, x18 C13 and x2 C19 outlets, C20 inlet
- Consigue plazos de pago de hasta 90 días de 500+ proveedores.
- Descuentos de reventa de hasta el 40%!
Enviar solicitud de precio
1
Formas de pago:
Condiciones del producto:
Oferta con plazo de entrega del fabricante
Entrega:Bajo pedido
El mejor precio:
Enviar solicitud de precio
Additional Information
- Part Number
- AP8858
- UPC
- 731304277026
- UNSPSC
- 39121017
Specifications
- Main Input Voltage
- 200 V || 208 V || 230 V
- Number Of Rack Unit
- 0U
- Provided Equipment
- Installation guide || Rack Mounting brackets || Serial configuration cable || Safety guide
Contractual warranty
- Warranty
- 2 years repair or replace
Environmental
- Storage Relative Humidity
- 5-95 %
- Ambient Air Temperature For Operation
- -5-60 °C
- Storage Altitude
- 0-50000 ft
- Ambient Air Temperature For Storage
- -25-65 °C
- Relative Humidity
- 5-95 %
- Operating Altitude
- 0...10000 ft
Physical
- Height
- 90.2 cm
- Net Weight
- 2.93 kg
- Mounting Location
- side
- Mounting Mode
- rack-mounted
- Color
- Black
- Width
- 5.6 cm
- Depth
- 4.4 cm
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP1712014_EN
- Sustainable Offer Status
- Green Premium product
- Take-Back
- Take-back program available
- Lead Free
- Yes
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- Optimized Energy Efficiency
- Energy efficient product
- Circularity Profile
- ENVEOLI1712014_EN
- Eu Rohs Directive
- Compliant
Input
- Input Frequency
- 50/60 Hz
- Line Rated Current
- 16 A
Overview
- Lead Time
- Usually in Stock
- Presentation
- APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
Conformance
- Product Certifications
- METI Denan || VDE
- Standards
- CSA C22.2 No. 60950 || IEC 60950 || UL 60950-1
Documentos
Data Sheet
DescargarOtras categorías
ActuadoresBloquesCables, tuberías y manguerasCompresoresControlAcoplamientos y AccesoriosCilindros y PistonesElectrónicaFiltrosHVACPCs industriales y HMIsIluminaciónTécnica linealMotoresFuente de alimentaciónTransmisión de energíaBombas y VálvulasEnergías renovablesRobóticaSellos, anillos y conectoresSensores y dispositivos de mediciónHerramientas y AccesoriosCNCOtros