- Prospective Line Isc
- 5 kA
- Network Frequency
- 50-60 Hz
- Power Dissipation In W
- forced cooling 128.0 W
- Line Current
- 23.8 A 100 V heavy duty) || 19.9 A 120 V heavy duty)
- Asynchronous Motor Control Profile
- quadratic voltage/frequency ratio || voltage/frequency ratio (V/f) || sensorless flux vector control
- Relative Symmetric Network Frequency Tolerance
- 5 %
- Apparent Power
- 8.3 kVA 240 V heavy duty)
- Net Weight
- 2 kg
- Type Of Polarization
- no impedance
- Frequency Resolution
- analog input converter A/D, 10 bits || display unit 0.1 Hz
- Switching Frequency
- 2...16 kHz adjustable || 4...16 kHz with derating factor
- Maximum Transient Current
- 25.0 A 60 s heavy duty) || 27.6 A 2 s heavy duty)
- Communication Service
- read holding registers (03) 29 words || write single register (06) 29 words || write multiple registers (16) 27 words || read/write multiple registers (23) 4/4 words || read device identification (43)
- Analogue Input Number
- 1
- Motor Slip Compensation
- preset in factory || adjustable
- Discrete Output Number
- 2
- Method Of Access
- server Modbus serial
- Number Of Addresses
- 1-247
- Speed Range
- 1-20
- Discrete Input Number
- 4
- Linearity Error
- +/- 0.3 % of maximum value analogue input
- Width
- 140 mm
- Transmission Rate
- 9.6 kbit/s || 19.2 kbit/s || 38.4 kbit/s
- Depth
- 141.2 mm
- Sampling Duration
- 20 ms +/- 1 ms logic input || 10 ms analogue input
- Maximum Output Frequency
- 4 kHz
- Height
- 184 mm
- Acceleration And Deceleration Ramps
- S || U || linear from 0 to 999.9 s
- Time Constant
- 20 ms +/- 1 ms for reference change
- Maximum Output Voltage
- 240 V
- Base Load Current At High Overload
- 16.7 A
- Speed Drive Output Frequency
- 0.5-400 Hz
- Transmission Frame
- RTU
- Relay Output Number
- 1
- Transient Overtorque
- 150-170 % of nominal motor torque depending on drive rating and type of motor
- Data Format
- 8 bits, configurable odd, even or no parity
- Connector Type
- 1 RJ45
- Analogue Output Number
- 1
- Physical Interface
- 2-wire RS 485
- Insulation
- electrical between power and control
- Tightening Torque
- 1.2 N.m
- Continuous Output Current
- 16.7 A 4 kHz
- Nominal Switching Frequency
- 4 kHz
- Quantity Per Set
- set of 1
- Braking To Standstill
- by DC injection
- Protection Type
- line supply overvoltage || line supply undervoltage || overcurrent between output phases and earth || overheating protection || short-circuit between motor phases || against input phase loss in three-phase || thermal motor protection via the drive by continuous calculation of I²t