Schneider Electric

ATV212HU75M3X

1 / 1
thumbnail

Descripción

Activo maduro
This Altivar 212 variable speed drive can feed 3-phase asynchronous motors. Its protection index is IP21. It works at a rated power up to 7.5kW / 10hp and a rated voltage from 200V to 240V AC. Its design is based on eco-energy with a reduction in energy consumption of up to 70% compared to a conventional control system. Thanks to its cable temperature rise reduction technology, the Altivar 212 drive offers immediate, disturbance-free operation avoiding additional options such as a line choke or DC choke to deal with current harmonics. It weighs 6.1kg and its dimensions are, 180mm wide, 232mm high, 170mm deep. It is specifically designed for the most common fluid management applications in tertiary sector buildings (HVAC) like heating, ventilation, air conditioning and pumping. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions). It is also CE, UL, CSA, C-Tick and NOM certified. The Altivar 212 offers optional motor chokes which can increase the maximum cable lengths between the drive and the motor and limit disturbance at the motor terminals. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. The Altivar 212 drive can easily be adapted to all building management systems thanks to its numerous functions and communication protocols integrated as standard, Modbus, METASYS N2, APOGEE FLN P1 and BACnet. It is eco-friendly and complies with directives such as RoHS, WEEE, etc.relating to environmental protection.
Country of Origin
ID
Part Number
ATV212HU75M3X
Tariff Code
85044090
EAN
3606480322389
UNSPSC
39122001
$2,282.00
net
1
Métodos de pago:
Mejor oferta de:
USProveedor de confianza de Automa.Net
Disponibilidad:
4 piezas
En stock
Actualizado en: 07-10-2024
Garantía:
24 meses
Entrega Estimada:
Bajo pedido
Condición:
Nuevo Precintado de Fábrica
Nuevo Precintado de Fábrica - Un artículo completamente nuevo, sin usar, sin abrir, sin daños, en su embalaje original sellado por el fabricante.
Un total de 20 Parts In-Stock de 5 Distributors
Proceso de Pago Seguro
Políticas de Devolución y Reembolso
Políticas de Envío
Políticas de Garantía

Ofertas Disponibles (5)

ATV212HU75M3X product image
Schneider Electric

ATV212HU75M3X

Condición:
Nuevo Precintado de Fábrica
Disponible:
10 piezas
En stock
Actualizado en: 08-11-2024
Oferta de:
SKProveedor de confianza de Automa.Net
Entrega Estimada:
Bajo pedido
Garantía:
12 meses
1
ATV212HU75M3X product image
Schneider Electric

ATV212HU75M3X

Condición:
Nuevos excedentes
Disponible:
2 piezas
En stock
Actualizado en: 08-11-2024
Oferta de:
USProveedor de confianza de Automa.Net
Entrega Estimada:
Bajo pedido
Garantía:
12 meses
1
$2,310.00
net
ATV212HU75M3X product image
Schneider Electric

ATV212HU75M3X

Condición:
Nuevos excedentes
Disponible:
1 pieza
En stock
Actualizado en: 21-10-2024
Oferta de:
GBProveedor de confianza de Automa.Net
Entrega Estimada:
Bajo pedido
1
ATV212HU75M3X product image
Schneider Electric

ATV212HU75M3X

Condición:
Nuevos excedentes
Disponible:
1 pieza
En stock
Actualizado en: 08-11-2024
Oferta de:
DEProveedor de confianza de Automa.Net
Entrega Estimada:
Bajo pedido
Garantía:
12 meses
1
ATV212HU75M3X product image
Schneider Electric

ATV212HU75M3X

Condición:
Usado
Disponible:
2 piezas
En stock
Actualizado en: 08-11-2024
Oferta de:
USProveedor de confianza de Automa.Net
Entrega Estimada:
Bajo pedido
Garantía:
6 meses
1
$1,584.00
net
Oferta con plazo de entrega del fabricante
Entrega:Bajo pedido
El mejor precio:
€660.22

Specifications

Product Destination
asynchronous motors
Range Of Product
Altivar 212
Product Or Component Type
variable speed drive
Ip Degree Of Protection
IP21
Motor Power Kw
7.5 kW
Phase
3 phase
Line Current
23.3 A 240 V || 27.9 A 200 V
[Us] Rated Supply Voltage
200...240 V - 15...10 %
Communication Port Protocol
Modbus || BACnet || LonWorks || METASYS N2 || APOGEE FLN
Supply Voltage Limits
170-264 V
Product Specific Application
pumps and fans in HVAC
Emc Filter
without EMC filter
Maximum Horse Power Rating
10 hp
Device Short Name
ATV212
Supply Frequency
50...60 Hz - 5...5 %

Contractual warranty

Warranty
18 months

Complementary

Prospective Line Isc
22 kA
Electrical Connection
VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 2.5-2.5 mm² / AWG 14 || L1/R, L2/S, L3/T terminal 16-16 mm² / AWG 6
Network Frequency
47.5...63 Hz
Discrete Input Logic
positive logic (source) F, R, RES), <= 5 V, >= 11 V || negative logic (sink) F, R, RES), >= 16 V, <= 10 V
Type Of Cable
without mounting kit 1 IEC cable 45 °C, copper 90 °C / XLPE/EPR || without mounting kit 1 IEC cable 45 °C, copper 70 °C / PVC || with UL Type 1 kit 3 UL 508 cable 40 °C, copper 75 °C / PVC
Height
232 mm
Acceleration And Deceleration Ramps
automatic based on the load || linear adjustable separately from 0.01 to 3200 s
Analogue Output Type
FM switch-configurable voltage 0...10 V DC 7620 Ohm 10 bits || FM switch-configurable current 0...20 mA 970 Ohm 10 bits
Speed Drive Output Frequency
0.5-200 Hz
Discrete Output Type
configurable relay logic FLA, FLC) NO - 100000 cycles || configurable relay logic FLB, FLC) NC - 100000 cycles || configurable relay logic RY, RC) NO - 100000 cycles
Transmission Frame
RTU
Torque Accuracy
+/- 15 %
Asynchronous Motor Control Profile
voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) || voltage/frequency ratio, 5 points || flux vector control without sensor, standard || voltage/frequency ratio - Energy Saving, quadratic U/f || voltage/frequency ratio, 2 points
Maximum Switching Current
5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R) || 5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R) || 2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R) || 2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R)
Communication Service
time out setting from 0.1 to 100 s || monitoring inhibitable || read device identification (43) || write multiple registers (16) 2 words maximum || write single register (06) || read holding registers (03) 2 words maximum
Transient Overtorque
120-120 % of nominal motor torque +/- 10 % 60 s
Insulation Resistance
>= 1 mOhm 500 V DC for 1 minute
Response Time
FM 2 ms +/- 0.5 ms analog || FLA, FLC 7 ms +/- 0.5 ms discrete || FLB, FLC 7 ms +/- 0.5 ms discrete || RY, RC 7 ms +/- 0.5 ms discrete
Data Format
8 bits, 1 stop, odd even or no configurable parity
Apparent Power
12.2 kVA 240 V
Dielectric Strength
2830 V DC between earth and power terminals || 4230 V DC between control and power terminals
Power Range
7-11 kW 200-240 V 3 phase
Net Weight
6.1 kg
Type Of Polarization
no impedance
Frequency Resolution
display unit 0.1 Hz || analog input 0.024/50 Hz
Accuracy
+/- 0.6 % VIA) for a temperature variation 60 °C || +/- 0.6 % VIB) for a temperature variation 60 °C || +/- 1 % FM) for a temperature variation 60 °C
Switching Frequency
6...16 kHz adjustable || 12...16 kHz with derating factor
Maximum Transient Current
35.2 A 60 s
Connector Type
1 RJ45 || 1 open style
Analogue Input Number
2
Motor Slip Compensation
adjustable || not available in voltage/frequency ratio motor control || automatic whatever the load
Motor Starter Type
variable speed drive
Discrete Output Number
2
Minimum Switching Current
3 mA 24 V DC configurable relay logic
Analogue Output Number
1
Physical Interface
2-wire RS 485
Power Dissipation In W
346 W
Continuous Output Current
32 A 230 V
Number Of Addresses
1-247
Tightening Torque
0.6 N.m VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES) || 2.5 N.m, 22 lb.in L1/R, L2/S, L3/T)
Discrete Input Type
F programmable 24 V DC level 1 PLC 4700 Ohm || R programmable 24 V DC level 1 PLC 4700 Ohm || RES programmable 24 V DC level 1 PLC 4700 Ohm
Speed Range
1-10
Isolation
electrical between power and control
Local Signalling
for DC bus energized 1 LED (red)
Linearity Error
VIA +/- 0.15 % of maximum value input || VIB +/- 0.15 % of maximum value input || FM +/- 0.2 % output
Specific Application
HVAC
Output Voltage
<= power supply voltage
Nominal Switching Frequency
12 kHz
Width
180 mm
Transmission Rate
9600 bps or 19200 bps
Braking To Standstill
by DC injection
Air Flow
118 m3/h
Depth
170 mm
Protection Type
overheating protection drive || line supply undervoltage drive || against input phase loss drive || thermal protection motor || motor phase break motor || with PTC probes motor || thermal power stage drive || short-circuit between motor phases drive || input phase breaks drive || overcurrent between output phases and earth drive || overvoltages on the DC bus drive || break on the control circuit drive || against exceeding limit speed drive || line supply overvoltage and undervoltage drive
Supply
internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection || internal supply 24 V DC 21-27 V), <200 A overload and short-circuit protection
Analogue Input Type
VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits || VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits || VIB configurable PTC probe 0...6 probes 1500 Ohm || VIA switch-configurable current 0...20 mA 250 Ohm 10 bits
Sampling Duration
2 ms +/- 0.5 ms F discrete || 2 ms +/- 0.5 ms R discrete || 2 ms +/- 0.5 ms RES discrete || 3.5 ms +/- 0.5 ms VIA analog || 22 ms +/- 0.5 ms VIB analog
Speed Accuracy
+/- 10 % of nominal slip 0.2 Tn to Tn
Option Card
communication card LonWorks

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP110204EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Circularity Profile
ENVEOLI1102030EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
CSA || C-tick || NOM 117 || UL
Standards
EN 61800-3 environments 1 category C3 || IEC 61800-3 environments 1 category C2 || IEC 61800-3 environments 1 category C3 || IEC 61800-3 || EN 61800-3 environments 1 category C1 || UL Type 1 || EN 61800-5-1 || IEC 61800-3 environments 1 category C1 || IEC 61800-3 environments 2 category C2 || IEC 61800-3 environments 2 category C3 || IEC 61800-3 environments 2 category C1 || EN 61800-3 environments 1 category C2 || IEC 61800-5-1 || EN 61800-3 environments 2 category C3 || EN 61800-3 environments 2 category C2 || EN 61800-3 environments 2 category C1 || EN 61800-3
Electromagnetic Compatibility
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5 || conducted radio-frequency immunity test level 3 IEC 61000-4-6 || voltage dips and interruptions immunity test IEC 61000-4-11
Ambient Air Temperature For Operation
-10-40 °C without derating) || 40-50 °C with derating factor)
Shock Resistance
15 gn 11 ms IEC 60068-2-27
Environmental Characteristic
classes 3C1 IEC 60721-3-3 || classes 3S2 IEC 60721-3-3
Marking
CE
Vibration Resistance
1.5 mm 3-13 Hz)EN/IEC 60068-2-6 || 1 gn 13-200 Hz)EN/IEC 60068-2-8
Noise Level
51 dB 86/188/EEC
Pollution Degree
3 IEC 61800-5-1
Regulation Loop
adjustable PI regulator
Ambient Air Temperature For Storage
-25-70 °C
Relative Humidity
5-95 % without condensation IEC 60068-2-3 || 5-95 % without dripping water IEC 60068-2-3
Assembly Style
with heat sink
Ip Degree Of Protection
IP20 on upper part without blanking plate on cover EN/IEC 61800-5-1 || IP20 on upper part without blanking plate on cover EN/IEC 60529 || IP21 EN/IEC 61800-5-1 || IP21 EN/IEC 60529 || IP41 on upper part EN/IEC 61800-5-1 || IP41 on upper part EN/IEC 60529
Operating Altitude
3280.84...9842.52 ft (1000...3000 m) limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m || <= 3280.84 ft (1000 m) without derating
Operating Position
vertical +/- 10 degree

Modelos CAD

traceparts
traceparts
Descargar