Schneider Electric
GV4AU137
1 / 1
Descripción
Activo maduro
TeSys GV electrical trip unit, MN undervoltage release, 110-130V AC 50/60Hz and 125V DC, for motor circuit breakers GV4. Opening of the the circuit breaker is ensured when the control voltage drops below 0.35 Uc, and possible between 0.35-0.7 Uc. Closing of the circuit breaker is possible when the control voltage is in limits 0.85-1.1 Uc. To be plugged inside the circuit breaker, connection by spring terminals. Multi standards certified (IEC, UL, CSA), Green Premium compliant (RoHS/REACh).- Country of Origin
- FR
- Part Number
- GV4AU137
- Tariff Code
- 85363010
- EAN
- 3606485444833
- UNSPSC
- 39121010
Métodos de pago:
- Mejor oferta de:
- Proveedor de confianza de Automa.Net
- Disponibilidad:
- 1 piezaEn stockActualizado en: 17-09-2024
- Garantía:
- 12 meses
- Entrega Estimada:
- Bajo pedido
- Condición:
- Nuevo Precintado de Fábrica
Nuevo Precintado de Fábrica - Un artículo completamente nuevo, sin usar, sin abrir, sin daños, en su embalaje original sellado por el fabricante.
Proceso de Pago Seguro
Políticas de Devolución y Reembolso
Políticas de Envío
Políticas de Garantía
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP2311042EN
- California Proposition 65
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation
- Product out of China RoHS scope. Substance declaration for your information.
- Circularity Profile
- ENVEOLI2311042EN
- Eu Rohs Directive
- Compliant with Exemptions
Specifications
- [Uc] Control Circuit Voltage
- 110...130 V AC 50/60 Hz || 125 V DC
- Range Compatibility
- TeSys TeSys GV4 || TeSys TeSys BV4
- Product Or Component Type
- voltage release
- Range
- TeSys
- Voltage Release Type
- undervoltage release
- Device Application
- control
- Device Short Name
- MN
Complementary
- Maximum Inrush Power In W
- 2 W
- Maximum Inrush Power In Va
- 7 VA
- Connections - Terminals
- spring terminals 1 0.5-1.5 mm² - cable stiffness: flexible without cable end
- Wire Stripping Length
- 8 mm
- [Ui] Rated Insulation Voltage
- 130 V IEC 60947-1
- Mounting Mode
- internal mounting
- Maximum Hold-In Power Consumption In W
- 2 W
- Mechanical Durability
- 20000 cycles
- Maximum Hold-In Power Consumption In Va
- 7 VA
- Threshold Tripping Voltage
- < 0.35 Un failsafe opening || 0.35...0.7 Un possible opening || 0.85...1.1 Un enabled closing
- Operating Time
- < 50 ms
Environment
- Quantity Per Set
- set of 1
Modelos CAD
traceparts
Descargar