Schneider Electric LC1D95N7

IEC Contactors, TeSys Deca, 95A, 60HP at 480VAC, 3 phase, 3 pole, 3 NO

1 / 1
Schneider Electric LC1D95N7 IEC Contactors, TeSys Deca, 95A, 60HP at 480VAC, 3 phase, 3 pole, 3 NO — Electrónica y PCB
Imagen de catálogo del fabricante

Descripción del producto

Ciclo de vida:

The TeSys Deca IEC contactors are engineered for optimal compatibility with diverse control systems. These contactors can be employed to create motor starters suitable for nearly any application.

TeSys D contactors come in 13 different ratings, catering to inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This particular 95A inductive 3 pole IEC contactor can be installed on a DIN rail or directly onto a panel.

The contactor boasts both horsepower and Kw motor ratings for global acceptance. It is rated for 25HP at 200-208VAC, 30HP at 240VAC, 60HP at 480VAC, and 60HP at 600VAC in three-phase applications. For single-phase use, it is rated for 7.5HP at 115VAC and 15HP at 240VAC.

The contactor comes with a 415VAC 50/60Hz coil. It features one normally open and one normally closed auxiliary contact as standard, with the NC contact being mirror certified. Screw clamp terminals are used for load and auxiliary connections.

The contactor measures 5.00 inches in height, 3.35 inches in width, and 5.12 inches in depth, weighing 3.55 lbs. It is certified to UL, CSA, IEC, CCC, EAC, and Marine standards, as well as meeting the requirements of RoHS/REACh, making it a Green Premium product.

Enviar consulta
Métodos de pago:

Detalles de la oferta

Mejor oferta de:
Proveedor de confianza — Reino Unido, miembro desde 2021
Disponibilidad:
2 piezas
En stock
Actualizado en: 31-10-2025
Condición:
Nuevo Precintado de Fábrica
Nuevo Precintado de Fábrica - Un artículo completamente nuevo, sin usar, sin abrir, sin daños, en su embalaje original sellado por el fabricante.
El Vendedor es responsable de enviar el producto y facturar

Especificaciones

Product Certifications
IECEE CB Scheme || UL || CSA || CCC || EAC || LROS (Lloyds register of shipping) || RINA || BV || DNV-GL
Standards
EN/IEC 60947-1 || EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || UL 60947-5-1 || CSA C22.2 No 60947-4-1 || CSA C22.2 No 60947-5-1 || GB/T 14048.4
Climatic Withstand
IACS E10 exposure to damp heat
Flame Retardance
V1 conforming to UL 94
Protective Treatment
THIEC 60068-2-30
Ip Degree Of Protection
IP20 front face IEC 60529

Ofertas Disponibles

(3)
LC1D95N7 Schneider Electric, Electrónica y PCB

Schneider Electric

Disponible:
1 pieza
Bajo pedido
Actualizado en: 22-08-2026
Oferta de:
Proveedor de confianza — Rumanía, miembro desde 2023, 1–4 empleados
LC1D95N7 Schneider Electric, Electrónica y PCB

Schneider Electric

Disponible:
0 piezas
Bajo pedido
Actualizado en: 04-09-2026
Oferta de:
Proveedor de confianza — Alemania, miembro desde 2024

Acceda a nuestra plataforma para encontrar más ofertas

Regístrese ahora para explorar 36 millones de ofertas de proveedores verificados de todo el mundo.

  • Comparar ofertas globalmente
  • Contacto directo con el proveedor
  • Peticiones de oferta, presupuestos y pedidos
  • Búsqueda de listas de materiales
Registrate14 días de prueba gratuita
Oferta con plazo de entrega del fabricante
Directamente del fabricante, con un plazo de entrega confirmado, predecible y totalmente transparente.
Obtener presupuesto

Documentos

Hoja de datos

Hoja de datos para Schneider Electric LC1D95N7, incluyendo especificaciones y características.

Descargar hoja de datos
TracePartsTraceParts

Modelos CAD

Modelo CAD 3D y planos técnicos, listos para tu software de diseño.

Descargar modelo CAD

Productos compatibles

LA4DA2N Schneider Electric
LA4DA2N
Schneider Electric
TeSys D suppressor module, for LC1D80-D150 (3P), LC1D40-D115 (4P) contactors
LAD8N02 Schneider Electric
LAD8N02
Schneider Electric
TeSys Deca instantaneous auxiliary contact block, for LC
LAD8N11 Schneider Electric
LAD8N11
Schneider Electric
TeSys Deca instantaneous auxiliary contact block, for LC
LAD8N20 Schneider Electric
LAD8N20
Schneider Electric
TeSys Deca instantaneous auxiliary contact block, for LC
LADN02 Schneider Electric
LADN02
Schneider Electric
TeSys D instantaneous auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADN04 Schneider Electric
LADN04
Schneider Electric
TeSys D instantaneous auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADN11 Schneider Electric
LADN11
Schneider Electric
TeSys D instantaneous auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADN13 Schneider Electric
LADN13
Schneider Electric
Schneider Electric's TeSys Deca auxiliary contact block offers 1NO+3NC instantaneous contacts rated up to 10A 690V AC. It is suitable for safety applications and can be easily mounted on front by clip-on.
LADN20 Schneider Electric
LADN20
Schneider Electric
TeSys D instantaneous auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADN22 Schneider Electric
LADN22
Schneider Electric
TeSys D instantaneous auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADN31 Schneider Electric
LADN31
Schneider Electric
TeSys D instantaneous auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADN40 Schneider Electric
LADN40
Schneider Electric
The TeSys Deca auxiliary contact block provides four normally open (NO) contacts for integration into control circuits with LC1D09 to LC1D150 contactors.
LADR0 Schneider Electric
LADR0
Schneider Electric
TeSys D time delay auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADR2 Schneider Electric
LADR2
Schneider Electric
TeSys D time delay auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADR4 Schneider Electric
LADR4
Schneider Electric
TeSys D time delay auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADS2 Schneider Electric
LADS2
Schneider Electric
TeSys D time delay auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADT0 Schneider Electric
LADT0
Schneider Electric
TeSys D time delay auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADT2 Schneider Electric
LADT2
Schneider Electric
TeSys D time delay auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADT4 Schneider Electric
LADT4
Schneider Electric
TeSys D time delay auxiliary contact block, for contactors LC1D, LC1F and control relays CAD

Piezas de recambio

LX1D6N7 Schneider Electric
LX1D6N7
Schneider Electric
TeSys D - contactor coil - LX1D6 - 415 V AC 50/60 Hz for 80 & 95 A contactor

Perspectivas del mercado

AutomaINSIGHTS panel de análisis

Obtenga análisis en tiempo real y datos de mercado para optimizar sus decisiones de compra de este componente y productos similares.

  • Datos de disponibilidad de existencias en tiempo real de más de 700 distribuidores MRO de Europa y EE.UU.
  • Análisis de precios por estado (nuevos, usados, reacondicionados) con precios medios de mercado
  • Supervisión de la disponibilidad de componentes críticos para evitar paradas de producción
  • Perspectivas de optimización del inventario basadas en las tendencias de abastecimiento del mercado