Schneider Electric LC1DT20P7

IEC Contact Relay, TeSys Deca, Non-reversing, 20A Resistive Load, 4 Poles, 4 NO, 230VAC 50/60Hz Coil, Open Style

1 / 1
Schneider Electric LC1DT20P7 IEC Contact Relay, TeSys Deca, Non-reversing, 20A Resistive Load, 4 Poles, 4 NO, 230VAC 50/60Hz Coil, Open Style — Contactores y relés
Imagen de catálogo del fabricante

Descripción del producto

Ciclo de vida:

Introducing the TeSys D Contact Relay, a versatile component designed for optimal integration into various control systems. This relay is suitable for creating motor starters for a wide range of applications.

The TeSys D Contact Relay is available in 13 different contactor ratings, catering to inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This specific model is a 4 pole IEC contact relay.

This relay can be mounted on DIN rail or directly onto a panel, providing flexibility in installation. It comes with four normally open power contacts, each rated for a 20A resistive load. The relay is powered by a 230VAC 50/60Hz coil.

In addition to the power contacts, this relay also features one normally open and one normally closed auxiliary contact as standard. The NC contact is mirror certified for enhanced reliability.

The load and auxiliary connections are made using screw clamp terminals. A comprehensive line of accessories ensures that you can meet the requirements of most applications.

With dimensions of 3.35 inches in height, 1.77 inches in width, and 3.62 inches in depth, this relay weighs 0.80 lbs. It is certified to UL, CSA, IEC, CCC, EAC, and Marine standards, making it a reliable choice for various environments.

Furthermore, the TeSys D Contact Relay meets the RoHS/REACh requirements, positioning it as a Green Premium product. This means it is not only efficient but also environmentally friendly.

Enviar consulta
Métodos de pago:

Detalles de la oferta

Mejor oferta de:
Proveedor de confianza — Reino Unido, miembro desde 2021
Disponibilidad:
5 piezas
En stock
Actualizado en: 31-10-2025
Condición:
Nuevo Precintado de Fábrica
Nuevo Precintado de Fábrica - Un artículo completamente nuevo, sin usar, sin abrir, sin daños, en su embalaje original sellado por el fabricante.
El Vendedor es responsable de enviar el producto y facturar

Especificaciones

Product Certifications
CCC || DNV || RINA || UL || BV || LROS (Lloyds register of shipping) || GOST || CSA || GL
Standards
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
Climatic Withstand
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Flame Retardance
V1 conforming to UL 94
Protective Treatment
THIEC 60068-2-30
Ip Degree Of Protection
IP20 front face IEC 60529

Ofertas Disponibles

(5)
LC1DT20P7 Schneider Electric, Contactores y relés

Schneider Electric

Disponible:
1 pieza
Bajo pedido
Actualizado en: 22-08-2026
Oferta de:
Proveedor de confianza — Rumanía, miembro desde 2023, 1–4 empleados
LC1DT20P7 Schneider Electric, Contactores y relés

Schneider Electric

Disponible:
1 pieza
En stock
Actualizado en: 05-09-2026
Oferta de:
Proveedor de confianza — Reino Unido, miembro desde 2023
Garantía:
12 meses
LC1DT20P7 Schneider Electric, Contactores y relés

Schneider Electric

Disponible:
0 piezas
Bajo pedido
Actualizado en: 04-09-2026
Oferta de:
Proveedor de confianza — Alemania, miembro desde 2024

Acceda a nuestra plataforma para encontrar más ofertas

Regístrese ahora para explorar 36 millones de ofertas de proveedores verificados de todo el mundo.

  • Comparar ofertas globalmente
  • Contacto directo con el proveedor
  • Peticiones de oferta, presupuestos y pedidos
  • Búsqueda de listas de materiales
Registrate14 días de prueba gratuita
Oferta con plazo de entrega del fabricante
Directamente del fabricante, con un plazo de entrega confirmado, predecible y totalmente transparente.
Obtener presupuesto

Documentos

Hoja de datos

Hoja de datos para Schneider Electric LC1DT20P7, incluyendo especificaciones y características.

Descargar hoja de datos
TracePartsTraceParts

Modelos CAD

Modelo CAD 3D y planos técnicos, listos para tu software de diseño.

Descargar modelo CAD

Productos compatibles

LAD4RCU Schneider Electric
LAD4RCU
Schneider Electric
TeSys D suppressor module, for LC1D09-D38, LC1DT20-DT40 contactors and CAD control relays
LAD4VU Schneider Electric
LAD4VU
Schneider Electric
A TeSys D suppressor module designed for LC1D09-D38 and LC1DT20-DT40 contactors and CAD control relays. It provides varistor protection limiting transient voltage to 2 Uc max.
LAD6K10M Schneider Electric
LAD6K10M
Schneider Electric
TeSys Deca mechanical latch block, for LC1D09-D80A, LC1DT20-DT80A contactors and CAD control relays (except devices with low consumption coils)
LAD8N02 Schneider Electric
LAD8N02
Schneider Electric
TeSys Deca instantaneous auxiliary contact block, for LC
LAD8N11 Schneider Electric
LAD8N11
Schneider Electric
TeSys Deca instantaneous auxiliary contact block, for LC
LAD8N20 Schneider Electric
LAD8N20
Schneider Electric
TeSys Deca instantaneous auxiliary contact block, for LC
LAD92560 Schneider Electric
LAD92560
Schneider Electric
TeSys Deca - Terminal block - 4P - Screw clamp
LAD9ET1 Schneider Electric
LAD9ET1
Schneider Electric
TeSys D protective cover, for preventing access to the moving contact carrier
LAD9ET1S Schneider Electric
LAD9ET1S
Schneider Electric
TeSys D safety protective cover, for preventing access to the moving contact carrier
LAD9V2 Schneider Electric
LAD9V2
Schneider Electric
TeSys D mechanical interlock, for contactors LC1D09-D38 and LC1DT20-DT40
LADN02 Schneider Electric
LADN02
Schneider Electric
TeSys D instantaneous auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADN04 Schneider Electric
LADN04
Schneider Electric
TeSys D instantaneous auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADN11 Schneider Electric
LADN11
Schneider Electric
TeSys D instantaneous auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADN13 Schneider Electric
LADN13
Schneider Electric
Schneider Electric's TeSys Deca auxiliary contact block offers 1NO+3NC instantaneous contacts rated up to 10A 690V AC. It is suitable for safety applications and can be easily mounted on front by clip-on.
LADN20 Schneider Electric
LADN20
Schneider Electric
TeSys D instantaneous auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADN22 Schneider Electric
LADN22
Schneider Electric
TeSys D instantaneous auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADN22S Schneider Electric
LADN22S
Schneider Electric
TeSys D instantaneous auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADN31 Schneider Electric
LADN31
Schneider Electric
TeSys D instantaneous auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADN40 Schneider Electric
LADN40
Schneider Electric
The TeSys Deca auxiliary contact block provides four normally open (NO) contacts for integration into control circuits with LC1D09 to LC1D150 contactors.
LADR0 Schneider Electric
LADR0
Schneider Electric
TeSys D time delay auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADR2 Schneider Electric
LADR2
Schneider Electric
TeSys D time delay auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADR4 Schneider Electric
LADR4
Schneider Electric
TeSys D time delay auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADS2 Schneider Electric
LADS2
Schneider Electric
TeSys D time delay auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADT0 Schneider Electric
LADT0
Schneider Electric
TeSys D time delay auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADT2 Schneider Electric
LADT2
Schneider Electric
TeSys D time delay auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADT4 Schneider Electric
LADT4
Schneider Electric
TeSys D time delay auxiliary contact block, for contactors LC1D, LC1F and control relays CAD
LADT9R1 Schneider Electric
LADT9R1
Schneider Electric
TeSys D kit for changeover contactors assembly, for 4-pole contactors LC1DT20-DT40
LADT9R1V Schneider Electric
LADT9R1V
Schneider Electric
TeSys D kit for changeover contactors assembly, for 4-pole contactors LC1DT20-DT40

Piezas de recambio

LXD1P7 Schneider Electric
LXD1P7
Schneider Electric
TeSys D replacement coil 230V AC 50/60Hz, for TeSys D contactors

Productos relacionados

LC1DFKP7 Schneider Electric
LC1DFKP7
Schneider Electric
TeSys D contactor, 3 poles (3NO), for switching 3-phase capacitor banks up to 12.5kVAR@400V 50Hz.
LC1D188D7 Schneider Electric
LC1D188D7
Schneider Electric
TeSys D contactor, 4 poles (2NO+2NC), for non-inductive load applications up to 32A/690V AC-1
LC1D32BD Schneider Electric
LC1D32BD
Schneider Electric
TeSys D contactor, 3 poles (3NO), for motor control applications up to 32A/690V AC-3/3e (15kW@400V)
LC1D096P7 Schneider Electric
LC1D096P7
Schneider Electric
TeSys D contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3/3e (4kW@400V)
LC1D40008E7 Schneider Electric
LC1D40008E7
Schneider Electric
TeSys Deca contactor, 4 poles (2NO+2NC), for non-inductive load applications up to 60A/690V AC-1
LC1DT32B7 Schneider Electric
LC1DT32B7
Schneider Electric
TeSys D contactor, 4 poles (4NO), for non-inductive load applications up to 32A/440V AC-1
LC1D183P7 Schneider Electric
LC1D183P7
Schneider Electric
TeSys D contactor, 3 poles (3NO), for motor control applications up to 18A/690V AC-3/3e (7
LC1D80BD Schneider Electric
LC1D80BD
Schneider Electric
TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 80A/1000V AC-3/AC-3e (37kW@400V)

Perspectivas del mercado

AutomaINSIGHTS panel de análisis

Obtenga análisis en tiempo real y datos de mercado para optimizar sus decisiones de compra de este componente y productos similares.

  • Datos de disponibilidad de existencias en tiempo real de más de 700 distribuidores MRO de Europa y EE.UU.
  • Análisis de precios por estado (nuevos, usados, reacondicionados) con precios medios de mercado
  • Supervisión de la disponibilidad de componentes críticos para evitar paradas de producción
  • Perspectivas de optimización del inventario basadas en las tendencias de abastecimiento del mercado
Comenzar