1 / 1
thumbnail

Descripción

Activo maduro
TeSys K reversing contactor, 3 poles (3NO), for motor control applications up to 6A/690V AC-3 (2.2kW@400V). It provides low consumption 24V DC coils with transient suppressor module, 2NC built-in auxiliary contacts, connection by screw clamp terminals. For operating rates until 600 cycles/hour in AC-3 and environments until 50°C, it procures reliability and durability to standard applications. Compact (90mm width), DIN-rail mounting or screw fixing. With pre-wired reversing power connections, mechanical interlock (without electrical interlocking). Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
Country of Origin
FR
Part Number
LP5K0601BW3
Tariff Code
85364190
EAN
3389110500622
UNSPSC
39121529
£112.20
net
1
Métodos de pago:
Mejor oferta de:
GBProveedor de confianza de Automa.Net
Disponibilidad:
8 piezas
En stock
Actualizado en: 07-11-2024
Entrega Estimada:
Bajo pedido
Condición:
Nuevo Precintado de Fábrica
Nuevo Precintado de Fábrica - Un artículo completamente nuevo, sin usar, sin abrir, sin daños, en su embalaje original sellado por el fabricante.
Un total de 479 Parts In-Stock de 19 Distributors
Proceso de Pago Seguro
Políticas de Devolución y Reembolso
Políticas de Envío
Políticas de Garantía

Ofertas Disponibles (22)

LP5K0601BW3 product image
Schneider Electric

LP5K0601BW3

Condición:
Nuevo Precintado de Fábrica
Disponible:
6 piezas
En stock
Actualizado en: 07-11-2024
Oferta de:
NLProveedor de confianza de Automa.Net
Entrega Estimada:
Bajo pedido
1
€120.27
net
LP5K0601BW3 product image
Schneider Electric

LP5K0601BW3

Condición:
Nuevo Precintado de Fábrica
Disponible:
6 piezas
En stock
Actualizado en: 07-11-2024
Oferta de:
DEProveedor de confianza de Automa.Net
Entrega Estimada:
Bajo pedido
1
€126.50
net
LP5K0601BW3 product image
Schneider Electric

LP5K0601BW3

Condición:
Nuevo Precintado de Fábrica
Disponible:
6 piezas
En stock
Actualizado en: 07-11-2024
Oferta de:
ITProveedor de confianza de Automa.Net
Entrega Estimada:
Bajo pedido
1
€129.15
net
LP5K0601BW3 product image
Schneider Electric

LP5K0601BW3

Condición:
Nuevo Precintado de Fábrica
Disponible:
8 piezas
En stock
Actualizado en: 07-11-2024
Oferta de:
ESProveedor de confianza de Automa.Net
Entrega Estimada:
Bajo pedido
1
€132.61
net
LP5K0601BW3 product image
Schneider Electric

LP5K0601BW3

Condición:
Nuevo Precintado de Fábrica
Disponible:
14 piezas
En stock
Actualizado en: 07-11-2024
Oferta de:
FRProveedor de confianza de Automa.Net
Entrega Estimada:
Bajo pedido
1
€159.49
net
Oferta con plazo de entrega del fabricante
Entrega:Bajo pedido
El mejor precio:
€33.79

Environment

Mechanical Robustness
shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27 || vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6 || vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6 || shocks contactor opened, on X axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on Y axis6 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on X axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Y axis10 Gn for 11 ms IEC 60068-2-27
Ambient Air Temperature For Operation
-25-50 °C
Height
58 mm
Net Weight
0.49 kg
Flame Retardance
V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
Ambient Air Temperature For Storage
-50-80 °C
Protective Treatment
TC IEC 60068 || TC DIN 50016
Ip Degree Of Protection
IP20 VDE 0106
Operating Altitude
6561.68 ft (2000 m) without derating
Width
90 mm
Depth
57 mm

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1503003EN
Sustainable Offer Status
Green Premium product
Toxic Heavy Metal Free
Yes
Reach Regulation
Free of Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
Reach Free Of Svhc
Yes
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
Pro-active China RoHS declaration (out of China RoHS legal scope)
Circularity Profile
ENVEOLI1503003EN
Eu Rohs Directive
Compliant

Complementary

Minimum Switching Current
5 mA for signalling circuit
Control Circuit Voltage Limits
operational: 0.7...1.30 Uc (at <50 °C) || drop-out: 0.1...0.7 Uc (at <50 °C)
Non Overlap Distance
0.5 mm
Hold-In Power Consumption In W
1.8-1.8 W 20 °C
Insulation Resistance
> 10 MOhm for signalling circuit
Coil Technology
built-in bidirectional peak limiting diode suppressor
Minimum Switching Voltage
17 V for signalling circuit
Inrush Power In W
1.8-1.8 W 20 °C)
Auxiliary Contacts Type
instantaneous 1 NC
Heat Dissipation
1.8-1.8 W

Specifications

Product Certifications
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
Interlocking Type
mechanical
[Uc] Control Circuit Voltage
24 V DC
[Ue] Rated Operational Voltage
power circuit 690 V AC 50/60 Hz || signalling circuit <= 690 V AC 50/60 Hz
Average Impedance
3 mOhm - Ith 20 A 50 Hz for power circuit
Auxiliary Contact Composition
1 NC
[Ith] Conventional Free Air Thermal Current
20 A (at 50 °C) for power circuit || 10 A (at 50 °C) for signalling circuit
Standards
EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1
Mounting Support
plate || rail
Control Circuit Type
DC low consumption
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Contactor Application
motor control
Rated Breaking Capacity
110 A at 415 V conforming to IEC 60947 || 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 110 A at 220...230 V conforming to IEC 60947 || 110 A at 380...400 V conforming to IEC 60947 || 70 A at 660...690 V conforming to IEC 60947
Product Or Component Type
reversing contactor
Irms Rated Making Capacity
110 A AC for power circuit conforming to NF C 63-110 || 110 A AC for power circuit conforming to IEC 60947 || 110 A AC for signalling circuit conforming to IEC 60947
Product Name
TeSys K
Associated Fuse Rating
25 A gG at <= 440 V for power circuit || 25 A aM for power circuit || 10 A gG for signalling circuit conforming to IEC 60947 || 10 A gG for signalling circuit conforming to VDE 0660
[Uimp] Rated Impulse Withstand Voltage
8 kV
Connections - Terminals
screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 2 0.75-4 mm²flexible without cable end || screw clamp terminals 2 0.34-1.5 mm²flexible with cable end
Range
TeSys
Pole Contact Composition
3 NO
Device Presentation
preassembled with reversing power busbar
Utilisation Category
AC-4 || AC-3 || AC-3e
[Ie] Rated Operational Current
6 A at <= 440 V AC AC-3 for power circuit || 6 A at <= 440 V AC AC-3e for power circuit
Maximum Operating Rate
3600 cyc/h
Electrical Durability
1.3 Mcycles 6 A AC-3 <= 440 V || 1.3 Mcycles 6 A AC-3e <= 440 V || 0.05 Mcycles 36 A AC-4 <= 440 V
Mechanical Durability
5 Mcycles
Poles Description
3P
Operating Time
10...20 ms coil de-energisation and NO opening || 30...40 ms coil energisation and NO closing
Tightening Torque
0.8-1.3 N.m screw clamp terminals Philips No 2 || 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm || 0.8-1.3 N.m screw clamp terminals pozidriv No 2
Overvoltage Category
III
Motor Power Kw
1.5 kW 220...230 V AC 50/60 Hz || 2.2 kW 380...415 V AC 50/60 Hz || 3 kW 440 V AC 50/60 Hz || 3 kW 480 V AC 50/60 Hz || 3 kW 500...600 V AC 50/60 Hz || 3 kW 660...690 V AC 50/60 Hz
[Ui] Rated Insulation Voltage
power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || signalling circuit 690 V IEC 60947-4-1 || signalling circuit 690 V IEC 60947-5-1 || signalling circuit 600 V UL 508 || power circuit 600 V CSA C22.2 No 14 || signalling circuit 600 V CSA C22.2 No 14
Device Application
control
Device Short Name
LP5K
[Icw] Rated Short-Time Withstand Current
90 A 50 °C - 1 s for power circuit || 85 A 50 °C - 5 s for power circuit || 80 A 50 °C - 10 s for power circuit || 60 A 50 °C - 30 s for power circuit || 45 A 50 °C - 1 min for power circuit || 40 A 50 °C - 3 min for power circuit || 80 A - 1 s for signalling circuit || 90 A - 500 ms for signalling circuit || 110 A - 100 ms for signalling circuit || 20 A 50 °C - >= 15 min for power circuit

Modelos CAD

traceparts
traceparts
Descargar