1 / 1
thumbnail

Descripción

Activo maduro
This product is part of the XCS range, an offer of safety switches. The limit switch is a device that converts a mechanical motion into an electrical control signal. It has 2 normally closed + 1 normally opened, slow break contacts, normally closed contact with positive opening operation. It is a switch with a rated operational current of 1.5A at 240V AC, 3A at 120V AC, 0.27A at 250V DC, 0.55 at 125V DC and a conventional enclosed thermal current of 6A. It is designed to operate in hazardous environments. It is furnished with screw clamp terminals for electrical connection and 2 cable entry tapped for PG13 cable gland. The electromagnet interlocking on de-energization and unlocking on energization of solenoid. It offers long mechanical durability which is about 1 million operating cycles. It is an IP67 rated product. The key operated turret head limit switch has a rectangular metal body which is made of Zamak. Its dimensions are 98mm (Width) x 44mm (Depth) x 146mm (Height) and weighs 1.14kg. It is intended as far as safety is concerned all dangerous machines in all sectors are involved. Such as packaging, handling, robotics, machine tools, presses, automotive sector. This product is certified by CSA and UL. It meets CSA C22.2 No 14, EN/IEC 60947-5-1, EN/IEC 60204-1, EN/ISO 12100, EN 1088/ISO 14119 and UL 508 standards. It offers protection of operators by stopping the machine when the actuator attached to the machine guard is withdrawn from the head of the switch. Safety switches for the protection of operators, by controlling the safe opening and interlocking of guards and covers in your installations.
Country of Origin
FR
Part Number
XCSE73117
Tariff Code
85365080
EAN
3389110708769
UNSPSC
39122213
€150.00
net
1
Métodos de pago:
Mejor oferta de:
LVProveedor de confianza de Automa.Net
Disponibilidad:
1 pieza
En stock
Actualizado en: 08-11-2024
Entrega Estimada:
Bajo pedido
Condición:
Nuevos excedentes
Nuevos excedentes - Un artículo nuevo, sin usar, sin daños y sin garantía del fabricante. El artículo puede venir sin embalaje original o en embalaje de reemplazo. Si se proporciona, es posible que la caja haya sido abierta.
Un total de 3 Parts In-Stock de 3 Distributors
Proceso de Pago Seguro
Políticas de Devolución y Reembolso
Políticas de Envío
Políticas de Garantía

Ofertas Disponibles (2)

XCSE73117 product image
Schneider Electric

XCSE73117

Condición:
Nuevos excedentes
Disponible:
1 pieza
En stock
Actualizado en: 21-10-2024
Oferta de:
GBProveedor de confianza de Automa.Net
Entrega Estimada:
Bajo pedido
1
XCSE73117 product image
Schneider Electric

XCSE73117

Condición:
Nuevos excedentes
Disponible:
1 pieza
En stock
Actualizado en: 08-11-2024
Oferta de:
DEProveedor de confianza de Automa.Net
Entrega Estimada:
Bajo pedido
Garantía:
12 meses
1
Oferta con plazo de entrega del fabricante
Entrega:Bajo pedido
El mejor precio:
Enviar solicitud de precio

Specifications

[Us] Rated Supply Voltage
24 V - 20...10 %
Range Of Product
Telemecanique Safety switches XCS
Cable Entry
2 entries tapped Pg 13.5
Electrical Connection
terminal 1 x 0.5...2 x 1.5 mm² with or without cable end
Locking Options Description
with interlocking, locking by solenoid
Solenoid Contacts Type And Composition
2 NC slow-break, simultaneous)
Product Or Component Type
safety switch
Signalling Circuit Voltage
24/48 V 20...52 V)
Component Name
XCSE
Design
rectangular
Material
metal
Head Type
key operated turret head
Contacts Type And Composition
2 NC + 1 NO
Contact Operation
slow-break, break before make
Local Signalling
for guard open/guard closed and locked 2 LEDs (green or orange)
Electromagnet Interlocking
locking on de-energisation and unlocking on energisation of solenoid
Cable Outer Diameter
9-12 mm
Number Of Poles
3

Contractual warranty

Warranty
18 months

Complementary

Height
146-146 mm
Short-Circuit Protection
10 A cartridge fuse gG (gl)
Minimum Actuation Speed
0.01 m/s
Signalling Circuit Consumption
7 mA
[Ithe] Conventional Enclosed Thermal Current
6 A
Power Consumption In Va
10 VA inrush || 10 VA sealed
Supply Voltage Type
AC/DC
Head Material
zamak
Signalling Circuit Type
AC/DC
Net Weight
1.14 kg
[Uimp] Rated Impulse Withstand Voltage
6 kV EN/IEC 60947-5-1
Maximum Operating Rate
10 cyc/mn for maximum durability
[Ui] Rated Insulation Voltage
50 VEN/IEC 60947-1 signalling circuit
Positive Opening
with NC contact
Load Factor
1
[Ie] Rated Operational Current
0.55 A 125 V, DC-13, Q300 EN/IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 || 3 A 120 V, AC-15, B300 EN/IEC 60947-5-1 || 1.5 A 240 V, AC-15, B300 EN/IEC 60947-5-1
Minimum Actuator Force For Extraction
20 N
Mechanical Durability
1000000 cycles
Maximum Actuation Speed
0.5 m/s
Body Material
zamak
Safety Reliability Data
B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
Width
98 mm
Actuator Forcible Withdrawal Rtc
2000 N
Depth
44 mm
Protection Type
overvoltage protection signalling circuit
Supply Frequency
50/60 Hz
Safety Level
can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP110916EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Circularity Profile
ENVEOLI110903EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
CSA || UL
Ambient Air Temperature For Operation
-25-40 °C
Standards
UL 508 || EN/ISO 12100 || EN 1088/ISO 14119 || EN/IEC 60204-1 || EN/IEC 60947-5-1 || CSA C22.2 No 14
Shock Resistance
10 gn 11 ms IEC 60068-2-27
Vibration Resistance
5 gn 10-500 Hz)IEC 60068-2-6
Ip Degree Of Protection
IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1
Ambient Air Temperature For Storage
-40-70 °C
Electrical Shock Protection Class
class I EN/IEC 61140
Protective Treatment
TC