- Electrical Connection
- 1 conductor cable 0.14-2.5 mm² - AWG 26...AWG 14 - solid - without cable end IEC 60947-1 || 2 conductors cable 0.14-1.5 mm² - AWG 26...AWG 16 - solid - without cable end IEC 60947-1 || 1 conductor cable 0.14-4 mm² - AWG 26...AWG 12 - flexible - with cable end IEC 60947-1 || 2 conductors cable 0.14-1.5 mm² - AWG 26...AWG 16 - flexible - with cable end IEC 60947-1
- [Us] Rated Supply Voltage
- 24...240 V AC/DC 50/60 Hz - 10...10 %
- Height
- 108 mm
- Maximum Switching Current
- 5 mA AC/DC
- Short-Circuit Protection
- 0.4 A fuse fast blow
- Modulation Technique
- O-QPSK
- [Uimp] Rated Impulse Withstand Voltage
- 4 kV
- Status Led
- 1 LED Green power ON || 2 LEDs Green relay ON || 2 LEDs Green function mode || 1 LED green and yellow reception signal
- Output Contacts
- 2 C/O
- Communication Port Protocol
- Zigbee green power 2.4 GHz IEEE 802.15.4
- Switching Capacity In Va
- 1250 VA
- Response Time
- < 30 ms after transmitter clicks
- Operating Position
- any position without derating
- Antenna Gain
- 0 dBi
- Utilisation Category
- AC-15 : B300 IEC 60947-5-1 || DC-12 IEC 60947-5-1
- Net Weight
- 0.13 kg
- Maximum Switching Voltage
- 250 V AC/DC
- Time Delay Range
- 0.5 s - 15...15 %)
- Nominal Output Current
- 0.3 A 48 V DC IEC 60947-5-1 || 3 A 24 V DC UL 508 || 1.5 A 240 V AC IEC 60947-5-1 || 3 A 120 V AC IEC 60947-5-1 || 3 A 240 V AC UL 508 || 3 A 24 V DC CSA C22.2 No 14 || 3 A 240 V AC CSA C22.2 No 14
- Input Output Isolation
- galvanic isolation
- Surge Withstand
- 1 kV differential mode IEC 61000-4-5 || 2 kV common mode IEC 61000-4-5
- Rated Short-Duration Power Frequency Withstand Voltage
- 1.5 kV 50 Hz IEC 60947-5-1
- Maximum Sensing Distance
- 100 m in free field || 25 m transmitter in a plastic box type XAL D and receiver in a metal enclosure || 40 m transmitter in box type XAL D, receiver in metal enclosure and use relay-antenna
- Max Power Consumption In W
- 1 mW
- Number Of Channels
- 1
- Breaking Capacity
- 15 W
- Mounting Support
- 35 mm symmetrical DIN rail conforming to IEC 60715 || mounting plate
- Housing Material
- self-extinguishing plastic
- Breaking Capacity
- 750 VA
- Control Circuit Frequency
- 50...60 Hz +/- 10 %
- Width
- 36 mm
- Output Type
- 2 relays
- Depth
- 75 mm
- Tightening Torque
- 0.5-1 N.m IEC 60947-1
- Maximum Power Consumption In W
- 4 W AC/DC
- Bandwidth