Phoenix Contact
2702077
1 / 1
Description
19" Ethernet communication unit for networking systems and stations via SHDSL technology. Data rates of up to 30 Mbps, distances of up to 20 km on in-house copper cables via line, star, and ring structures. Diagnostics via LEDs or software.- Country of Origin
- DE
- Part Number
- 2702077
- Tariff Code
- 85176200
- EAN
- 4046356945516
- UPC
- 4046356945516
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Function
- Management
- Plug and Play, diagnostics via PSI-CONF software or web-based management (only with managed Ethernet extenders)
Note
- Utilization restriction
- EMC: class A product, see manufacturer's declaration in the download area
Serial interface
- Interface 1
- Ethernet interface, 10/100Base-T(X) in acc. with IEEE 802.3u
- Interface
- Ethernet
- No. of ports
- 4
- Connection method
- RJ45 socket, shielded
- Transmission length
- < 100 m (shielded twisted pair)
- Protocols supported
- Transparent protocol for IPv4 and IPv6
- Serial transmission speed
- 10/100 Mbps, auto negotiation
- Interface 2
- SHDSL interface according to ITU-T G.991.2.bis
- No. of ports
- 12 (2-wire operation)
- Connection method
- Socket M8
- Transmission length
- < 20 km (Depending on data rate and cable cross section)
- Serial transmission speed
- 4-wire operation: 64 kbps - 30 Mbps
- Serial transmission speed
- 2-wire operation: 32 kbps - 15.3 Mbps
- Interface 3
- USB 2.0
- Connection method
- USB Type B
- Transmission length
- < 5 m (only for configuration and diagnostics)
Dimensions
- Caption
- Dimensional drawing
- Width
- 438 mm
- Height
- 178 mm
- Depth
- 330 mm
Ambient conditions
- Ambient temperature (operation)
- 5 °C - 35 °C (Cabinet temperature)
- Ambient temperature (storage/transport)
- 0 °C - 50 °C
- Permissible humidity (operation)
- 10 % - 95 % (non-condensing)
- Degree of protection
- IP20
- Noise immunity
- EN 61000-6-2
Environmental Product Compliance
- REACh SVHC
- Lead 7439-92-1
- China RoHS
- Environmentally Friendly Use Period = 50
- China RoHS
- For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Protective circuit
- IEC test classification
- B2
- IEC test classification
- C1
- IEC test classification
- C2
- IEC test classification
- C3
- IEC test classification
- D1
- VDE requirement class
- B2
- VDE requirement class
- C1
- VDE requirement class
- C2
- VDE requirement class
- C3
- VDE requirement class
- D1
- Maximum continuous voltage U<sub>C</sub>
- 185 V DC
- Maximum continuous voltage U<sub>C</sub>
- 130 V AC
- Rated current
- ≤ 380 mA (25 °C)
- Operating effective current I<sub>C</sub> at U<sub>C</sub>
- ≤ 6 µA
- Residual current I<sub>PE</sub>
- ≤ 4 µA
- Nominal discharge current I<sub>n</sub> (8/20) µs (line-line)
- ≤ 5 kA
- Nominal discharge current I<sub>n</sub> (8/20) µs (line-earth)
- ≤ 5 kA
- Pulse discharge current I<sub>imp</sub> (10/350) µs
- 2.5 kA (Number of pulses category D1)
- Total discharge current I<sub>total</sub> (8/20) µs
- 10 kA
- Nominal pulse current Ian (10/1000) µs (line-line)
- 100 A
- Nominal pulse current Ian (10/1000) µs (line-earth)
- 100 A
- Nominal pulse current Ian (10/700) µs (line-line)
- 150 A
- Nominal pulse current Ian (10/700) µs (line-earth)
- 150 A
- Voltage protection level U<sub>p</sub> (line-line)
- 250 V (B2 - 100 A)
- Voltage protection level U<sub>p</sub> (line-line)
- ≤ 250 V (C1 - 500 A)
- Voltage protection level U<sub>p</sub> (line-line)
- ≤ 410 V (C2 - 5 kA)
- Voltage protection level U<sub>p</sub> (line-line)
- ≤ 250 V (C3 - 100 A)
- Voltage protection level U<sub>p</sub> (line-earth)
- ≤ 580 V (B2 - 100 A)
- Voltage protection level U<sub>p</sub> (line-earth)
- ≤ 580 V (C1 - 500 A)
- Voltage protection level U<sub>p</sub> (line-earth)
- ≤ 790 V (C2 - 5 kA)
- Voltage protection level U<sub>p</sub> (line-earth)
- ≤ 300 V (C3 - 100 A)
- Response time t<sub>A</sub> (line-line)
- ≤ 100 ns
- Response time t<sub>A</sub> (line-earth)
- ≤ 100 ns
- Input attenuation aE, sym.
- typ. 0.3 dB (≤ 2,8 MHz / 100 Ω)
- Input attenuation aE, sym.
- typ. 3 dB (≤ 25 MHz / 100 Ω)
- Cut-off frequency fg (3 dB), sym. in 100 Ohm system
- 25 MHz
- Capacity (line-line)
- 55 pF
- Capacity (line-earth)
- 7 pF
- Resistance in series
- 3.3 Ω 20 %
- Surge protection fault message
- none
- Impulse durability (line-line)
- C1 - 1 kV/500 A
- Impulse durability (line-line)
- C2 - 10 kV/5 kA
- Impulse durability (line-line)
- B2 - 4 kV/100 A
- Impulse durability (line-earth)
- B2 - 4 kV/100 A
- Impulse durability (line-earth)
- C1 - 1 kV/500 A
- Impulse durability (line-earth)
- C2 - 10 kV/5 kA
- Impulse durability (line-earth)
- D1 - 1 kA
Standards and Regulations
- Electromagnetic compatibility
- Conformance with EMC Directive 2014/30/EU
- Noise immunity
- EN 61000-6-2
- Vibration (operation)
- DIN EN 60068-2-6
- Conformance
- CE-compliant
Power supply
- Nominal supply voltage
- 230 V AC (50 Hz - 60 Hz)
- Supply voltage range
- 100 V AC - 240 V AC
- Typical current consumption
- < 300 mA (220 V AC)