1 / 1
thumbnail

Description

19" Ethernet communication unit for networking systems and stations via SHDSL technology. Data rates of up to 30 Mbps, distances of up to 20 km on in-house copper cables via line, star, and ring structures. Diagnostics via LEDs or software.
Country of Origin
DE
Part Number
2702077
Tariff Code
85176200
EAN
4046356945516
UPC
4046356945516
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Function

Management
Plug and Play, diagnostics via PSI-CONF software or web-based management (only with managed Ethernet extenders)

Note

Utilization restriction
EMC: class A product, see manufacturer's declaration in the download area

Serial interface

Interface 1
Ethernet interface, 10/100Base-T(X) in acc. with IEEE 802.3u
Interface
Ethernet
No. of ports
4
Connection method
RJ45 socket, shielded
Transmission length
< 100 m (shielded twisted pair)
Protocols supported
Transparent protocol for IPv4 and IPv6
Serial transmission speed
10/100 Mbps, auto negotiation
Interface 2
SHDSL interface according to ITU-T G.991.2.bis
No. of ports
12 (2-wire operation)
Connection method
Socket M8
Transmission length
< 20 km (Depending on data rate and cable cross section)
Serial transmission speed
4-wire operation: 64 kbps - 30 Mbps
Serial transmission speed
2-wire operation: 32 kbps - 15.3 Mbps
Interface 3
USB 2.0
Connection method
USB Type B
Transmission length
< 5 m (only for configuration and diagnostics)

Dimensions

Caption
Dimensional drawing
Width
438 mm
Height
178 mm
Depth
330 mm

Ambient conditions

Ambient temperature (operation)
5 °C - 35 °C (Cabinet temperature)
Ambient temperature (storage/transport)
0 °C - 50 °C
Permissible humidity (operation)
10 % - 95 % (non-condensing)
Degree of protection
IP20
Noise immunity
EN 61000-6-2

Environmental Product Compliance

REACh SVHC
Lead 7439-92-1
China RoHS
Environmentally Friendly Use Period = 50
China RoHS
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Protective circuit

IEC test classification
B2
IEC test classification
C1
IEC test classification
C2
IEC test classification
C3
IEC test classification
D1
VDE requirement class
B2
VDE requirement class
C1
VDE requirement class
C2
VDE requirement class
C3
VDE requirement class
D1
Maximum continuous voltage U<sub>C</sub>
185 V DC
Maximum continuous voltage U<sub>C</sub>
130 V AC
Rated current
≤ 380 mA (25 °C)
Operating effective current I<sub>C</sub> at U<sub>C</sub>
≤ 6 µA
Residual current I<sub>PE</sub>
≤ 4 µA
Nominal discharge current I<sub>n</sub> (8/20) µs (line-line)
≤ 5 kA
Nominal discharge current I<sub>n</sub> (8/20) µs (line-earth)
≤ 5 kA
Pulse discharge current I<sub>imp</sub> (10/350) µs
2.5 kA (Number of pulses category D1)
Total discharge current I<sub>total</sub> (8/20) µs
10 kA
Nominal pulse current Ian (10/1000) µs (line-line)
100 A
Nominal pulse current Ian (10/1000) µs (line-earth)
100 A
Nominal pulse current Ian (10/700) µs (line-line)
150 A
Nominal pulse current Ian (10/700) µs (line-earth)
150 A
Voltage protection level U<sub>p</sub> (line-line)
250 V (B2 - 100 A)
Voltage protection level U<sub>p</sub> (line-line)
≤ 250 V (C1 - 500 A)
Voltage protection level U<sub>p</sub> (line-line)
≤ 410 V (C2 - 5 kA)
Voltage protection level U<sub>p</sub> (line-line)
≤ 250 V (C3 - 100 A)
Voltage protection level U<sub>p</sub> (line-earth)
≤ 580 V (B2 - 100 A)
Voltage protection level U<sub>p</sub> (line-earth)
≤ 580 V (C1 - 500 A)
Voltage protection level U<sub>p</sub> (line-earth)
≤ 790 V (C2 - 5 kA)
Voltage protection level U<sub>p</sub> (line-earth)
≤ 300 V (C3 - 100 A)
Response time t<sub>A</sub> (line-line)
≤ 100 ns
Response time t<sub>A</sub> (line-earth)
≤ 100 ns
Input attenuation aE, sym.
typ. 0.3 dB (≤ 2,8 MHz / 100 Ω)
Input attenuation aE, sym.
typ. 3 dB (≤ 25 MHz / 100 Ω)
Cut-off frequency fg (3 dB), sym. in 100 Ohm system
25 MHz
Capacity (line-line)
55 pF
Capacity (line-earth)
7 pF
Resistance in series
3.3 Ω 20 %
Surge protection fault message
none
Impulse durability (line-line)
C1 - 1 kV/500 A
Impulse durability (line-line)
C2 - 10 kV/5 kA
Impulse durability (line-line)
B2 - 4 kV/100 A
Impulse durability (line-earth)
B2 - 4 kV/100 A
Impulse durability (line-earth)
C1 - 1 kV/500 A
Impulse durability (line-earth)
C2 - 10 kV/5 kA
Impulse durability (line-earth)
D1 - 1 kA

Standards and Regulations

Electromagnetic compatibility
Conformance with EMC Directive 2014/30/EU
Noise immunity
EN 61000-6-2
Vibration (operation)
DIN EN 60068-2-6
Conformance
CE-compliant

Power supply

Nominal supply voltage
230 V AC (50 Hz - 60 Hz)
Supply voltage range
100 V AC - 240 V AC
Typical current consumption
< 300 mA (220 V AC)

Related products